background image

The BackPlane Configuration View

3-21

MMAC-Plus Management Views

Configuring the 9F120-08 FDDI Concentrator Module

The 9F120-08 is an FDDI concentrator for use with single attached FDDI nodes, 
such as a UNIX workstation or Þleserver. It has eight industry standard FDDI 
MIC MMF Master ports. A MUX on the 9F120-08 allows the module to dual-
attach to FNB-1 primary or secondary and FNB-2 primary or secondary. Each 
master port on the module can be individually assigned to one of the two rings to 
which the module is connected, as can the moduleÕs MAC encoding. To alter the 
9F120-08Õs backplane attachment:

1.

In the BackPlane Configuration view, click the left mouse button on either 
FNB-1 or FNB-2 in the middle of the 9F120-08 module front panel display. 
The FNB Configuration window (Figure 3-8) will appear.

Figure 3-8. FNB ConÞguration Window - 9F120-08

2.

Connect the module to FNB-1 and FNB-2 by clicking the left mouse button on 
the appropriate, color-coded ring switch symbol (

 — blue for FNB-1 

primary, green for FNB-1 secondary; magenta for FNB-2 primary, yellow for 
FNB-2 secondary). FNB rings to which the module is connected will be 
elongated.

3.

Associate the master ports with one of the two FNB rings to which the module 
is connected:

a.

Click the left mouse button on a port index to the right of the FNB 
configuration window. A pull-down menu will appear.

b.

Drag to the appropriate option: FNB-1 Primary/Secondary or FNB-2 
Primary/Secondary
.

Color-coding of each port index will reflect the associated ring.

Содержание SmartSwitch 6000

Страница 1: ...Cabletron Systems Using MMAC Plus Remote Management Guide TM The Complete Networking Solution...

Страница 2: ......

Страница 3: ...EW LANVIEW Secure Multi Media Access Center MiniMMAC and TRMM are registered trademarks and Bridge Router Interface Modules BRIM A100 CRBRIM W E CRXMIM CXRMIM Desktop Network Interface Distributed LAN...

Страница 4: ...RISC System 6000 and Workplace Shell are trademarks of International Business Machines Corporation i960 microprocessor is a registered trademark and Intel and Multichannel are trademarks of Intel Cor...

Страница 5: ...rred 2 Used or copied for use in a backup computer if any computer for which it was acquired is inoperative 3 Reproduced for safekeeping archives or backup purposes 4 Modified adapted or combined with...

Страница 6: ...er because no anti virus system is 100 reliable we strongly caution you to write protect and then prior to installing verify that the Licensed Software is virus free with an anti virus system in which...

Страница 7: ...agement Views 3 1 General View Information 3 2 Changing the Current View 3 3 Changing the Default View 3 3 The Chassis View 3 4 Environmental Module Status 3 4 System Status 3 5 Client Modules 3 6 Mod...

Страница 8: ...9E133 36 Module 3 17 Con guring the 9F120 08 FDDI Concentrator Module 3 19 Con guring the 9F116 01 Module 3 20 Con guring the 9T122 Series Token Ring MicroLAN Module 3 22 The FNB Ring Con guration Win...

Страница 9: ...four components to the backplane Two components are currently implemented the Flexible Network Bus FNB composed of two dual FDDI networks that provide up to 400 Mbps of data bandwidth and a two channe...

Страница 10: ...oughly to understand MMAC Plus Remote Management Using This Manual This manual covers management operations directly related to the monitoring and control of the chassis including the con guration of...

Страница 11: ...s please feel free to contact Cabletron Systems Technical Support via one of the following methods By Mail Cabletron Systems 35 Industrial Way P O Box 5005 Rochester NH 03866 5005 By Internet Mail sup...

Страница 12: ...chnical data provided in this manual Their procedures are referenced where appropriate but are not repeated in this manual Cabletron Systems Module User s Guides and Module Local Management Guides for...

Страница 13: ...are discovered and created as SNMP devices Second when you initialize a Chassis View for MMAC Plus management you must con gure it with a hub name along with the IP address and type of each module in...

Страница 14: ...e management a In the Enter chassis name field type in a unique descriptive name up to eight characters to represent the chassis This name is only used to identify the chassis by name and to identify...

Страница 15: ...as not been documented its current functionality is identical to the 9F116 module Other modules are not yet supported via Remote Management Note that when you select a module its community name field...

Страница 16: ...w will reappear automatically to inform you of a con guration problem Any incorrectly described module will appear highlighted in red and will have a button to its right Clicking on will display one o...

Страница 17: ...View displays environmental information for the individual client modules including power consumption and operating temperature and lets you view and manage the fan speed and power supplies A BackPlan...

Страница 18: ...ould normally be re ected in these elds is unavailable to remote management Other information is read from the rst module that MMAC Plus Remote Management detects in the chassis upon initializing Fiel...

Страница 19: ...e MMAC Plus window and drag down to select Chassis Environment Backplane Config or Chassis Setup The selected view will immediately appear or 1 Click on View in the menu bar at the top of the MMAC Plu...

Страница 20: ...l interfaces on individual client modules The following sections detail using the Chassis View Figure 3 2 The Chassis View Environmental Module Status When your MMAC Plus is modelled in the Chassis vi...

Страница 21: ...red by the external ambient temperature sensor This eld is also color coded as follows Humidity This eld displays the non condensing humidity level of the MMAC Plus System Status The System Status por...

Страница 22: ...ating or has not responded to a management poll within the number of retries Yellow The module has experienced an alarm or trap condition or it has failed its power up diagnostics test Ethernet FDDI a...

Страница 23: ...t is trying to establish a link but has not yet been successful Ports which are not connected and which have not been disabled by management will display this status Enabling and Disabling a Client Mo...

Страница 24: ...Temperature windows Environmental Module Status The Environmental Module Status portion of the Environmental Status view displays the same information as it does in the Chassis view Refer to pages 3 4...

Страница 25: ...controlled by ambient temperature level sensor To do so 1 Click on the appropriate fan speed selection Auto or Full Power Subsystem The Power Subsystem elds displays power consumption information in...

Страница 26: ...C Plus Management Views 3 10 The Environmental Status View Redund MMAC Plus chassis If this power supply fails the system will revert to battery back up if the chassis is so equipped or it will shut d...

Страница 27: ...d will be green if it is outside this range the eld will be red INB Termination This eld displays the current voltage for the INB Termination Power Bus This is a color coded eld If voltage to the INB...

Страница 28: ...odule s power supply See the following section Module Power View Temperature Gauge The color coded Temperature gauge eld graphically displays the module s current temperature in Fahrenheit The exact t...

Страница 29: ...e indicates the following Volts The current voltage being supplied by the selected module s 5 volt DC to DC converter for use by the module The acceptable normal limits for voltage from the converter...

Страница 30: ...ority Number field A drop down menu will appear with available priority settings 1 to 14 where a lower number indicates a higher priority 2 Drag to select the module priority of choice 3 Click The new...

Страница 31: ...cing an abnormal condition this is the default selection 3 Click Power Admin Status This eld lets you control the DC to DC power converter You can set the module s power to POWER ON Enable the onboard...

Страница 32: ...hut down its DC to DC power converter The diagnostic controller will remain operative Blue The temperature cannot be determined from module unknown Red Operating at cold status Yellow Operating at coo...

Страница 33: ...ature condition or Disabled module s power converter will continue to operate after experiencing an abnormal temperature condition this is the default selection 3 Click The BackPlane Configuration Vie...

Страница 34: ...two backplane FNB networks via a dual attached bridging routing interface This interface attaches simultaneously to both the primary and secondary FDDI ring of FNB 1 or FNB 2 The interface is also en...

Страница 35: ...View 3 19 MMAC Plus Management Views A physical switch at the back of the module connects it to FNB 1 primary and secondary ring FNB 2 primary and secondary or bypasses it from either or both FNBs to...

Страница 36: ...ntly connected to the FNB a dual line will display from the bridge route interface to either FNB 1 primary and secondary or FNB 2 primary and secondary with its MAC on either the primary or secondary...

Страница 37: ...e left mouse button on either FNB 1 or FNB 2 in the middle of the 9F120 08 module front panel display The FNB Configuration window Figure 3 8 will appear Figure 3 8 FNB Con guration Window 9F120 08 2...

Страница 38: ...cates the module is bypassed from the associated FNB and will not forward frames onto or receive them from that FNB network A single ring will appear to the right of the FNB network from which the mod...

Страница 39: ...et of dual lines between FNB 1 and Bridge Interface 1 one set between Bridge Interface 2 and the front panel ports Between FNB 2 and the front panel ports one set of dual lines between FNB 2 and Bridg...

Страница 40: ...he 9T122 Series Token Ring MicroLAN Module The 9T122 series of modules are Token Ring MicroLAN Modules Each module supports two token ring MicroLAN networks from its front panel ports which can be use...

Страница 41: ...e the most effective use of network bandwidth for your site by allowing you to segment the FNB into smaller FDDI ring networks The window acts as a template for your network design since it graphicall...

Страница 42: ...connected to the FNB with its two MACs associated with FNB 1 primary and FNB 2 primary To segment the backplane FNB 1 Click the left mouse button on the interface index where you want to segment the...

Страница 43: ...multiplexer wrapped at slot 4 By wrapping multiplexers you can create two or more individual rings on each FNB note that the rings will not have redundancy however Figure 3 13 Wrap FNB 1 Right Example...

Страница 44: ...left mouse button on a module index You can be sure that it is the module of interest by checking the Slot IP field in the lower right corner of the view A pull down menu will appear 2 Drag to select...

Страница 45: ...sable port 3 7 discovery 2 1 E enable port 3 7 Environment View 3 1 Environmental Module 1 1 Environmental Module Status 3 4 Environmental Status view 3 7 EPIM 3 5 Ethernet Bridging Modules Port Displ...

Страница 46: ...Reset switch 3 13 Power Subsystem 3 9 Priority Number 3 13 R Redund Available 3 10 Redundancy 3 9 Reset Switch 3 13 run time 3 10 S SMB 1 1 Status Bar 3 3 System Management Bus 1 1 2 1 3 2 System Sta...

Отзывы: