Specifications

Technical Specifications

CPU

PowerPC
Intel i960 RISC based microprocessor

Memory

8 MB Flash Memory (expandable to 16 MB)
32 MB DRAM (local)
4 MB Memory (shared)

Network Interface

Four Cabletron Systems GPIMs

Performance

Module Switch Fabric bandwidth 3.3 Gbps
Module Throughput

2.2 Mpps

Source Address Table

16 K entries

Содержание MMAC-Plus 9G536-04

Страница 1: ...9033049 01 SmartSwitch 9000 9G536 04 Four Port Gigabit Ethernet Module User s Guide...

Страница 2: ......

Страница 3: ...ation NOTE This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC rules These limits are designed to provide reasonable protecti...

Страница 4: ...If the Program is exported from the United States pursuant to the License Exception CIV under the U S Export Administration Regulations You agree thatYou are a civil end user of the Program and agree...

Страница 5: ...YSTEMS 1 603 332 9400 Attn Legal Department 1 LICENSE You have the right to use only the one 1 copy of the Program provided in this package subject to the terms and conditions of this License Agreemen...

Страница 6: ...HE USE OR INABILITY TO USE THIS CABLETRON PRODUCT EVEN IF CABLETRON HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES BECAUSE SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF LIABILITY FOR CO...

Страница 7: ...ereof if such foreign produced direct product is subject to national security controls as identified on the U S Commerce Control List or is subject to State Department controls under the U S Munitions...

Страница 8: ...on When operating within their performance limitations laser transceiver output meets the Class 1 accessible emission limit of all three standards Class 1 levels of laser radiation are not considered...

Страница 9: ...1 EN 60950 Equipment Type Environment Networking Equipment for use in a Commercial or Light Industrial Environment We the undersigned hereby declare under our sole responsibility that the equipment p...

Страница 10: ...Notice viii...

Страница 11: ...g the Module into the SmartSwitch 9000 Chassis 2 6 The Reset Switch 2 8 Chapter 3 Technical Overview SmartSwitch Architecture 3 1 System Management Buses 3 2 SMB 1 Bus 3 3 SMB 10 Bus 3 3 System Diagno...

Страница 12: ...ts x Physical 5 2 Dimensions 5 2 Weight 5 2 Environment 5 2 GPIM 01 Speci cations 1000Base SX A 1 GPIM 09 Speci cations 1000Base LX A 2 Physical and Environmental Speci cations A 2 Regulatory Complian...

Страница 13: ...nt for multiple Gigabit Ethernet segments Features Connectivity The 9G536 04 features four interfaces for network connectivity via the front panel The front panel connections are made by connecting to...

Страница 14: ...Introduction 1 2 Figure 1 1 The 9G536 04 GIG ENET 9G536 04 4 3 2 1...

Страница 15: ...and powered up Runtime IP Address Discovery RAD checks the modules for an IP address If one has not yet been assigned module and SmartSwitch 9000 chassis IP address set to 0 0 0 0 RAD checks to see i...

Страница 16: ...w User s Guide Remote Monitoring RMON The 9G536 04 supports all nine Ethernet RMON groups The Statistics Alarms Events and History groups are enabled on all ports by default Cabletron Systems RMON Act...

Страница 17: ...by port basis Both devices must support the IEEE 802 3x standard for ow control to work Frame based 802 3x ow control is supported on all Ethernet ports operating in the full duplex mode 802 1p Port...

Страница 18: ...ts on the switch may be activated to operate under the Generic Attribute Registration Protocol GARP applications GARP VLAN Registration Protocol GVRP and or GARP Multicast Registration Protocol GMRP G...

Страница 19: ...Troubleshooting Guide WebView User s Guide SmartTrunk User s Guide Getting Help For additional support related to this device or document contact Cabletron Systems using one of the following methods W...

Страница 20: ...e problem e g changing mode switches rebooting the unit etc The serial and revision numbers of all involved Cabletron Systems products in the network A description of your network environment layout c...

Страница 21: ...precautions to prevent damage from Electrostatic Discharge ESD 3 Carefully examine the module checking for damage If any damage exists DO NOT install the module Contact Cabletron Systems immediately...

Страница 22: ...Installing the SmartSwitch 9000 Module 2 2 Figure 2 1 User Accessible Components SMB 1 PROM Flash SIMM Socket 32 MB DRAM i960 Processor DIP Switch Boot PROM 1 2 3 4 5 6 7 8...

Страница 23: ...t you can use the defaults or enter new parameters which are stored in NVRAM when the module is powered down and remain there until the switch is toggled again 6 Force BootP Download Toggling this swi...

Страница 24: ...this time this process may be stopped by resetting the module Resetting is done by pushing the reset button on the module power cycling the chassis or removing the module from the chassis and re inser...

Страница 25: ...device Check the orientation against Figure 2 2 Push the GPIM back until the 20 pin port engages the GPIM The latch mechanism engages when the GPIM connector seats properly in the port Figure 2 3 Ins...

Страница 26: ...cle in the lower right corner of the SmartSwitch 9000 chassis shown in Figure 2 4 3 Grasp the module and slide it into the slots Make sure that the module s circuit card is between the card guides as...

Страница 27: ...odule 7 FLNK 8 FLNK FLNK 10 FLNK INS 11 FLNK INS 12 RX TX RX TX RX Circuit Card Card Guides Metal Back Panel Jack for ESD wrist strap Warning Ensure that the circuit card is between the card guides Lo...

Страница 28: ...ower down the module and or restart the module To reset the module s i960 processor press the reset switch twice within three seconds To shut down the module press and hold the reset switch for three...

Страница 29: ...dhere to IEEE 802 1D DEC or none The default Spanning Tree Algorithm is 802 1D When operating in SecureFast switch mode all ltering forwarding decisions are made on a DA SA pair and its in and out por...

Страница 30: ...the SMB 1 and the SMB 10 These buses provide out of band management and inter module management communication I N B A B i960 Processor Smart Switch Fabric INB ASIC SMB 1 SMB 10 Ethernet Controller Dia...

Страница 31: ...h an EPIM connection full SNMP management of the SmartSwitch 9000 is available out of band from user data Modules which share the SMB 10 bus periodically send out loop back packets to ensure the valid...

Страница 32: ...9X4XX modules The rst generation modules communicate only on INB B using a 56 byte canonical frame format at 40 MHz If the newer module detects a rst generation module on the backplane it automatical...

Страница 33: ...s indicate the status of the module and may be used as an aid in troubleshooting Figure 4 1 shows the LANVIEW LEDs of the 9G536 04 module Figure 4 1 The LANVIEW LEDs GIG ENET 9G536 04 4 3 System Statu...

Страница 34: ...Yellow Flashing Crippled Not fully operational e g one bad port Yellow Green Booting Blinks yellow and green while booting Red Reset Normal power up reset Red Flashing Failed Fatal error has occurred...

Страница 35: ...State Green Flashing Activity port enabled Yellow Flashing Port in standby Red Flashing Transmit fault Red Diagnostic failure Off No activity port enabled Table 4 5 GPIM Receive LEDs LED Color State G...

Страница 36: ...LANVIEW LEDs 4 4...

Страница 37: ...i960 RISC based microprocessor Memory 8 MB Flash Memory expandable to 16 MB 32 MB DRAM local 4 MB Memory shared Network Interface Four Cabletron Systems GPIMs Performance Module Switch Fabric bandwidt...

Страница 38: ...nvironment Operating Temperature 5 to 40 C 41 to 104 F Storage Temperature 30 to 73 C 22 to 164 F Relative Humidity 5 to 90 non condensing Safety UL 1950 CSA C22 2 No 950 EN 60950 IEC 950 and 73 23 EE...

Страница 39: ...the GPIM 09 supports both multimode and single mode SMF ber cable GPIM 01 Specifications 1000Base SX The following speci cations for the Gigabit Ethernet GPIMs listed in Table A 1 though Table A 7 mee...

Страница 40: ...11 5 dBm 9 5 dBm Receive Sensitivity 20 dBm 20 dBm 20 dBm Link Power Budget 8 5 dBm 8 5 dBm 10 5 dBm Modal Bandwidth 1300 nm Range 62 5 m MMF 500 MHz km 2 550A Meters 50 m MMF 400 MHz km 2 550A Meters...

Страница 41: ...pliance The GPIMs meet the following safety and electromagnetic compatibility EMC requirements Table A 7 Regulatory Compliance Eye Safety fiber GPIMs only FDA CDRH 21 CFR 1040 Class 1 IEC 825 Issue 1...

Страница 42: ...GPIM Specifications A 4...