7F06-02 FDDI SmartSwitch Interface Module User’s Guide

1-5

 

1.5

GETTING HELP

 

If you need additional support related to this device, or if you have any 
questions, comments, or suggestions concerning this manual, contact the 
Cabletron Systems Global Call Center:

Before calling the Cabletron Systems Global Call Center, have the 
following information ready:

Your Cabletron Systems service contract number 

A description of the failure

A description of any action(s) already taken to resolve the problem 
(e.g., changing mode switches, rebooting the unit, etc.)

The serial and revision numbers of all involved Cabletron Systems 
products in the network

A description of your network environment (layout, cable type, etc.)

Network load and frame size at the time of trouble (if known)

The device history (i.e., have you returned the device before, is this a 
recurring problem, etc.)

Any previous Return Material Authorization (RMA) numbers

 

Phone

(603) 332-9400

Internet mail

[email protected]

FTP

ctron.com (134.141.197.25)

Login 

 

anonymous

 

Password 

 

your email address

 

BBS

(603) 335-3358 

Modem setting

8N1: 8 data bits, No parity, 1 stop bit

For additional information about Cabletron Systems or our 
products, visit our World Wide Web site:

 

http://www.cabletron.com/

 

For technical support, select:

 

Service and Support.

Содержание FDDI

Страница 1: ...Title Page 7F06 02 FDDI SmartSwitch Interface Module User s Guide 903 9031672 02...

Страница 2: ......

Страница 3: ...uct names mentioned in this manual may be trademarks or registered trademarks of their respective companies FCC NOTICE This device complies with Part 15 of the FCC rules Operation is subject to the fo...

Страница 4: ...If this equipment is used in a domestic environment radio disturbance may arise When such trouble occurs the user may be required to take corrective actions CABLETRON SYSTEMS INC PROGRAM LICENSE AGRE...

Страница 5: ...QUENTIAL DAMAGES IN NO EVENT SHALL CABLETRON OR ITS SUPPLIERS BE LIABLE FOR ANY DAMAGES WHATSOEVER INCLUDING WITHOUT LIMITATION DAMAGES FOR LOSS OF BUSINESS PROFITS BUSINESS INTERRUPTION LOSS OF BUSIN...

Страница 6: ...73 23 EEC EN 55022 EN 50082 1 EN 60950 Equipment Type Environment Networking Equipment for use in a Commercial or Light Industrial Environment We the undersigned hereby declare under our sole responsi...

Страница 7: ...PIM Module Specifications 2 1 2 1 1 FPIM 00 and FPIM 01 2 1 2 1 2 FPIM 02 and FPIM 04 2 2 2 1 3 FPIM 05 and FPIM 07 2 3 CHAPTER 3 INSTALLATION REMOVAL 3 1 Unpacking The 7F06 02 Module 3 1 3 2 Installi...

Страница 8: ...rtSwitch Interface Module User s Guide CHAPTER 5 TECHNICAL SPECIFICATIONS 5 1 Standards 5 1 5 2 EMI 5 1 5 3 EMC 5 1 5 4 Network Interfaces 5 1 5 5 Safety 5 2 5 6 Service 5 2 5 7 Physical 5 2 5 7 1 Dim...

Страница 9: ...pecial features of Cabletron Systems 7F06 02 Module This chapter also includes a list of related manuals Chapter 2 Network Requirements contains a list of available FPIMs and the network requirements...

Страница 10: ...7X00 SmartSwitch Module through the chassis backplane The front panel connections are standard Cabletron FPIMs There are two FPIMs for each channel These FPIMs allow the use of single mode or multimod...

Страница 11: ...ges or routers The 7C03 MMAC SmartSwitch is a unique module that can be installed in an MMAC Series chassis The 7C04 Workgroup SmartSwitch and the 7C04 R Workgroup SmartSwitch are stand alone chassis...

Страница 12: ...nel FPIMs provide FDDI connections allowing the use of single mode or multimode fiber cable with MIC or SC type connectors 1 4 RELATED MANUALS The following Cabletron Systems manuals supplement the pr...

Страница 13: ...ebooting the unit etc The serial and revision numbers of all involved Cabletron Systems products in the network A description of your network environment layout cable type etc Network load and frame s...

Страница 14: ...Chapter 1 Introduction 1 6 7F06 02 FDDI SmartSwitch Interface Module User s Guide...

Страница 15: ...s Fiber Port Interface Modules FPIM to provide front panel cable connections The FPIMs are user installable Refer to Section 3 2 Installing FPIMs 2 1 1 FPIM 00 and FPIM 01 The FPIM 00 and FPIM 01 prov...

Страница 16: ...connection The pinouts for both are listed in Table 2 3 The link distance is up to 100 meters on unshielded twisted pair cable as specified by ANSI TP PMD Table 2 2 Transmitter Power Parameters Parame...

Страница 17: ...ations for both devices are listed in Table 2 4 The link distance is up to 40 kilometers max and 25 kilometers typical on single mode fiber optic cable as specified by ANSI SMF PMD Table 2 4 FPIM 05 a...

Страница 18: ...Chapter 2 Network Requirements 2 4 7F06 02 FDDI SmartSwitch Interface Module User s Guide...

Страница 19: ...dule by using the following steps 1 Carefully remove the module from the shipping box Save the box and packing materials in the event the module must be reshipped 2 Remove the module from the plastic...

Страница 20: ...MAC SmartSwitch chassis by reversing the procedure in Section 3 3 2 Remove the blank front cover over the FPIM slot 3 Install the FPIM as shown in Figure 3 1 Ensure that the rear connector is seated f...

Страница 21: ...by following the instructions printed on the package 1 As a precaution power down the MMAC 8 before beginning the installation or removal of any modules At the very minimum the 7C03 must be pulled to...

Страница 22: ...before beginning the installation or removal of any modules At the very minimum the 7C03 must be pulled to disconnect it from the power source Damage to modules may result if this procedure is not fol...

Страница 23: ...artSwitch or SmartSwitch module by following the instructions printed on the package 1 As a precaution power down the MMAC 8 before beginning the installation or removal of any modules At the very min...

Страница 24: ...3 4 Installing the 7F06 02 Module in the 7C04 Workgroup SmartSwitch Figure 3 5 Installing the 7F06 02 Module in the 7C04 R Workgroup SmartSwitch SN 1 2 3 4 7X00 SP Screw Ejector Tab SN 7A06 01 SP FAN...

Страница 25: ...ion power down the MMAC 8 before beginning the installation or removal of any modules At the very minimum the 7C04 or 7C04 R must be pulled to disconnect it from the power source Damage to modules may...

Страница 26: ...hapter 3 Installation Removal 3 8 7F06 02 FDDI SmartSwitch Interface Module User s Guide Figure 3 7 Removing the 7F06 02 Module from the 7C04 R Workgroup SmartSwitch FANS SN 4 3 2 1 Ejector Tabs Screw...

Страница 27: ...atus monitoring system With LANVIEW LEDs the status of each transmit and receive port on the 7F06 02 Module can be determined at a glance This section discusses the function and purpose of the LEDs on...

Страница 28: ...Receive LEDs LED Color State Yellow Flashing Data activity flashing to steady on indicates rate Off No activity port can be disabled or enabled Table 4 2 Port Transmit LEDs LED Color State Green Flas...

Страница 29: ...ellow Green THRU No MAC on Secondary Primary Bypasses Board Green Green Red Yellow WRAP A MAC on Primary Green Yellow Red Yellow WRAP A No MAC on Primary Yellow Green Red Green WRAP B MAC on Primary Y...

Страница 30: ...Chapter 4 Troubleshooting 4 4 7F06 02 FDDI SmartSwitch Interface Module User s Guide...

Страница 31: ...Cabletron Systems reserves the right to change these specifications at any time without notice 5 1 STANDARDS IEEE 802 1D IEEE 802 3i 10BASE T 5 2 EMI The EMI requirements of FCC Part 15 Class A EN 55...

Страница 32: ...ll be a part to ensure that the total system meets allowed limits of conducted and radiated emissions This equipment meets the safety requirements of UL 1950 CSA C22 2 No 950 EN 60950 IEC 950 5 6 SERV...

Отзывы: