Chapter 3: Installation/Removal
7F06-02 FDDI SmartSwitch Interface Module User’s Guide
3-5
3.3.3
Installing in the 7C04 or 7C04-R Workgroup
SmartSwitch
The 7F06-02 Module is installed in the 7C04 or 7C04-R Workgroup
SmartSwitch using the following steps and referring to Figures 3-4 and
3-5.
Notes:
The top slot in the 7C04 Workgroup SmartSwitch is reserved for
the 7X00 SmartSwitch Module.
The bottom slot in the 7C04-R Workgroup SmartSwitch is
reserved for the 7X00 SmartSwitch Module.
Therefore, before installing the 7F06-02 module, attach the wrist
strap included with the SmartSwitch or SmartSwitch module by
following the instructions printed on the package.
1. As a precaution, power down the MMAC 8 before beginning the
installation or removal of any modules. At the very minimum, the
7C04 or 7C04-R must be pulled to disconnect it from the power
source. Damage to modules may result if this procedure is not
followed.
2. Remove the blank panel covering the slot in which the module will be
installed. All other slots must remain covered to ensure proper airflow
and cooling.
3. Install the module by sliding it into slots as shown in the appropriate
figure. Ensure that the printed circuit board (PCB) is between the card
guides, slides in straight, and engages the backplane connectors
properly.
4. Using a slotted screwdriver, tighten the top and bottom screws.
Содержание FDDI
Страница 1: ...Title Page 7F06 02 FDDI SmartSwitch Interface Module User s Guide 903 9031672 02...
Страница 2: ......
Страница 14: ...Chapter 1 Introduction 1 6 7F06 02 FDDI SmartSwitch Interface Module User s Guide...
Страница 18: ...Chapter 2 Network Requirements 2 4 7F06 02 FDDI SmartSwitch Interface Module User s Guide...
Страница 30: ...Chapter 4 Troubleshooting 4 4 7F06 02 FDDI SmartSwitch Interface Module User s Guide...