background image

Troubleshooting

HSIM-W6 Installation Guide

4-3

Table 4-4 HSIM-W6 ASYNC Modem Connection Pinout

PIN

Description

1

Transmit Data

2

Data Carrier Detect (DCD)

3

Data Set Ready (DSR)

4

Receive Data

5

Ground

6

Data Terminal Ready (DTR)

7

Request to Send (RTS)

8

Clear to Send (CTS)

Table 4-5 HSIM-W6 WAN Link (LNK) LED States

LED

Color

State

Link (LNK)

OFF

WAN interface not configured or not 
present

RED

No Link/Connection (Fault) on the 
WAN interface

AMBER

Transmit (TX) and/or receive (RX) 
traffic

GREEN

Link and port is active

GREEN (blinking)

Link and port is in standby

Содержание CyberSWITCH HSIM-W6

Страница 1: ...HSIM W6 Installation Guide WIDE AREA1 WIDE AREA2 HSIM W6 TELCO TELCO CPU LNK STS LNK STS LNK STS ASYNC 9032694 ...

Страница 2: ......

Страница 3: ... manual may be trademarks or registered trademarks of their respective companies FCC Notice This device complies with Part 15 of the FCC rules Operation is subject to the following two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation NOTE This equipment has been tested and f...

Страница 4: ...r and Cabletron Systems Inc Cabletron that sets forth your rights and obligations with respect to the Cabletron software program the Program contained in this package The Program may be contained in firmware chips or other media BY UTILIZING THE ENCLOSED PRODUCT YOU ARE AGREEING TO BECOME BOUND BY THE TERMS OF THIS AGREEMENT WHICH INCLUDES THE LICENSE AND THE LIMITATION OF WARRANTY AND DISCLAIMER ...

Страница 5: ...UCT EVEN IF CABLETRON HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES BECAUSE SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF LIABILITY FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES OR ON THE DURATION OR LIMITATION OF IMPLIED WARRANTIES IN SOME INSTANCES THE ABOVE LIMITATIONS AND EXCLUSIONS MAY NOT APPLY TO YOU United States Government Restricted Rights The enclosed product a was developed s...

Страница 6: ...ive 91 263 EEC EN 55022 EN 50082 1 EN 60950 Equipment Type Environment Networking Equipment for use in a Commercial or Light Industrial Environment We the undersigned hereby declare under our sole responsibility that the equipment packaged with this notice conforms to the above directives Manufacturer Legal Representative in Europe Mr Ronald Fotino Mr J Solari ___________________________________ _...

Страница 7: ...Management Capabilities 2 3 Optional Feature 2 4 HSIM W6 Firmware Support 2 4 WAN Protocols 2 4 Inverse Multiplexing 2 6 Firmware Data Compression 2 6 HDLC 2 7 DHCP and NAT 2 7 Frame Relay Protocol 2 8 Point to Point Protocol 2 9 PAP and CHAP Security 2 9 LQM 2 10 Multilink Protocol 2 10 ISDN 2 11 ISDN Back up 2 12 The IP OSPF Routing Protocol 2 12 IP OSPF Hierarchy 2 13 HDSL 2 15 Bridging and Rou...

Страница 8: ...erface Module 3 6 Installing an HSIM in a SmartSWITCH Chassis 3 9 CHAPTER 4 TROUBLESHOOTING Troubleshooting HSIM W6 Hardware 4 5 Power PWR LED is OFF 4 5 Processor CPU LED is OFF 4 5 Processor CPU LED is RED 4 6 ASYNC Console Connection 4 6 Link LNK LED is OFF 4 6 Link LNK LED is RED or GREEN 4 6 Link LNK LED is AMBER 4 6 Status STS LED is OFF 4 6 Status STS LED is AMBER 4 6 Status STS LED is GREE...

Страница 9: ...ote Network Station 4 11 Troubleshooting the Frame Relay Connection 4 12 APPENDIX A WPIM CABLE SPECIFICATIONS WPIM T1 A 1 WPIM SY A 3 EIA 449 A 4 V 35 A 5 EIA 232 A 7 X 21 A 8 EIA 530 EIA 530 ALT A EIA 530 A and EIA 530 A ALT A A 9 WPIM DDS A 11 WPIM E1 A 12 WPIM DI A 14 WPIM HDSL A 15 WPIM S T A 16 APPENDIX B SPECIFICATIONS AND STANDARDS COMPLIANCE Regulatory Compliance B 1 Individual WPIM Regula...

Страница 10: ...Contents viii HSIM W6 Installation Guide APPENDIX C NETWORK INFORMATION WORKSHEETS APPENDIX D FCC PART 68 USER S INFORMATION FOR HSIM W6 APPENDIX E GLOSSARY INDEX ...

Страница 11: ...ibes the hardware components and software protocols and features Chapter 3 Installation provides detailed installation instructions Chapter 4 Troubleshooting provides detailed troubleshooting tips using the LANVIEW LEDs on the HSIM W6 Appendix A WPIM Cable Specifications provides part number and connector information for WPIMs Appendix B Specifications and Standards Compliance provides hardware sp...

Страница 12: ...gement Guide to connect your HSIM to a WAN using a TELNET connection Document Conventions The following conventions are used throughout this guide NOTE Note symbol Calls the reader s attention to any item of information that may be of special importance TIP Tip symbol Conveys helpful hints concerning procedures or actions CAUTION Caution symbol Contains information essential to avoid damage to the...

Страница 13: ...c A description of your network environment layout cable type etc Network load and frame size at the time of trouble if known The serial and revision numbers of all involved Cabletron Systems products in the network The device history i e have you returned the device before is this a recurring problem etc Any previous Return Material Authorization RMA numbers Phone 603 332 9400 Internet mail suppo...

Страница 14: ...Chapter 1 Introduction 1 4 HSIM W6 Installation Guide ...

Страница 15: ...cal console connection Figure 2 1 The HSIM W6 HSIM W6 Hardware This section details the HSIM W6 hardware capabilities WAN Connection The HSIM W6 supports Point to Point Protocol PPP including Link Control Protocol LCP BNCP IPCP IPXCP LQM Multilink Protocol MP and CHAP and PAP ISDN BRI and Frame Relay protocols through one of the following WAN port interface modules WPIMs The WPIM T1 provides a T1 ...

Страница 16: ...a T1 interface through a front panel RJ45 port and includes a built in CSU DSU for direct connection to a T1 line The WPIM DI provides both Full T1 or Fractional T1 using 56 or 64 Kbps timeslots and also provides a second Drop and Insert interface which allows more than one device to share a single T1 connection The WPIM S T provides an Integrated Services Digital Network ISDN 128 Kbps Basic Rate ...

Страница 17: ... of new and updated firmware in conjunction with Cabletron Systems QuickSET or any device using BootP or TFTP protocols LANVIEW LEDs Cabletron Systems LANVIEW Status Monitoring and Diagnostics System is a troubleshooting tool that helps in the diagnosing of power failures collisions cable faults and link problems The LANVIEW LEDs are located on the HSIM W6 front panel Remote Management Capabilitie...

Страница 18: ...guration necessary to prioritize hardware over software compression HSIM W6 Firmware Support The HSIM W6 firmware supports IEEE 802 1d bridging and IP and IPX routing and OSI Layer 2 Inverse Multiplexing IMUX which allows both WAN channels to be used as a single high bandwidth WAN channel Wide Area Networking includes Point to Point Protocol PPP Frame Relay and ISDN Remote access is via Full or Fr...

Страница 19: ...Annex D and ITU Q 933 Annex A Frame Relay Data Encapsulation as defined by RFC 1490 Frame Relay Data Compression Protocol DCP as defined by FRF 9 PPP is a data link layer industry standard WAN protocol for transferring multi protocol data traffic over point to point connections With this protocol options such as security data compression and network protocols can be negotiated over the connection ...

Страница 20: ...ned ordered and transmitted to the LAN interface The IMUX function is fully configurable using QuickSET which is discussed in the QuickSet Configuration Guide Firmware Data Compression The STAC Electronics Stacker LZS Compression algorithm provides a minimum of 2 1 firmware data compression for the HSIM W6 over PPP and Frame Relay Firmware data compression is supported in software on each WAN inte...

Страница 21: ...SIM W6 acts as a DHCP server that allows individual clients PCs network equipment to take turns using a range of private IP addresses often referred to as local IP addresses and provides optional secondary setup features for these clients on a per port basis The HSIM W6 distributes these addresses dynamically assigning a local IP address to an individual client from a range of 253 available addres...

Страница 22: ...ncept of Virtual Circuits Vcs Vcs are two way software defined data paths between two ports that take the place of private lines in the network There are two types of Frame Relay connections Switched Virtual Circuits SVCs and Permanent Virtual Circuits PVCs Permanent Virtual Circuits or PVCs are set up via a network management system and initially defined as a connection between two sites or endpo...

Страница 23: ...he connection This device supports synchronous PPP over the ISDN port In Single Link Mode PPP uses one ISDN B channel for data transmission PPP runs over each ISDN B channel for two separate conversations split B channel In Multi Link Protocol Mode PPP simultaneously sends and receives data over two ISDN B channels on the same connection to optimize bandwidth usage The STAC Electronics Stacker LZS...

Страница 24: ...with the system name in the CHAP response The peer device then runs the same algorithm and compares the result with the expected value This authentication method depends upon a password or secret known only to both ends locally LQM Link Quality Monitoring LQM is a link control mechanism used with PPP to determine when and how often a link is dropping data in units of packets and octets Link Qualit...

Страница 25: ...ta If the two B channels are used for separate connections each provides up to 64 Kbps transfer rates Both channels can be used together to provide uncompressed data transfer at up to 128 Kbps The HSIM W6 can also transfer compressed data at up to 512 Kbps A Network Terminator device NT1 provides the interface between ISDN terminal router equipment and the ISDN service provider In the U S the NT1 ...

Страница 26: ...p interface Connect Retries Connect Retries allows the user to configure the number of tries to bring up the back up interface before giving up Backup Override Backup Override forces the back up interface to remain connected and does not allow the back up interface to switch back to the primary interface even if the primary interface is restored Input Idle Time out Input Idle Time out allows the u...

Страница 27: ... is an IGP Every OSPF routing domain must have a backbone An OSPF backbone distributes routing information between areas in an OSPF routing domain The backbone of an OSPF routing domain system is an OSPF area possessing an area id of 0 0 0 0 Areas Areas are groups of networks and attached hosts A router s topology database includes area links and summarized and external links depicting the autonom...

Страница 28: ...on of link state databases across adjacencies One DR is elected for each network and is elected by using the Hello Protocol If one or more routers have declared to be the DR in their Hello packets the one with the highest Router Priority becomes the DR If more than one router has identical router priority then the router with the highest router ID becomes DR Backup Designated Router Backup Designa...

Страница 29: ...idge examines a portion of each network frame called the header This header contains control information for the frame The bridge compares the destination address of the frame to a table of source addresses bridges dynamically learn the physical location of devices by logging the source addresses of each frame and the bridge port the frame was received on in the source address table In transparent...

Страница 30: ...upported the device uses the MAC address information to bridge the packet Operation of the HSIM W6 is influenced by routing and bridging controls and filters set during HSIM W6 configuration General IP routing and routing or bridging from specific remote routers are controls set during the configuration process IEEE 802 1d Bridging The HSIM W6 supports the IEEE 802 1d standard for LAN to LAN bridg...

Страница 31: ...rewall access filters provide a lot of flexibility to establish a powerful IP security barrier The HSIM W6 supports the IP Access Control from the ctip mib Internet Firewall Filter Bridge Filtering Bridge filtering allows a network administrator to control the flow of packets across the HSIM W6 Bridge filtering can be used to deny or allow packets based on a matched pattern using a specified posit...

Страница 32: ...tion updates Communication with the SNMP agent occurs over the LAN or WAN connection Any management application using SNMP over UDP IP has access to the local SNMP agent SNMP MIB Support SNMP MIBs are databases of objects used for managing and determining the status and configuration of an SNMP compliant device The following SNMP MIBs are supported by the HSIM W6 MIB II RFC1213 RMON MIB RFC1271 DS...

Страница 33: ...ps are notifications of network events sent by an SNMP compliant device to an SNMP management station The following SNMP Traps are supported by the HSIM W6 IETF Standard Traps Warm Start Trap Type Code 1 RFC1214 Bridge New Root Trap Type Code 1 RFC1493 Bridge Topology Change Trap Type Code 2 RFC1493 Cabletron Enterprise Traps Port Segmented Trap Type Code 257 0x101 rrev4 mib Port Operational Trap ...

Страница 34: ...nterface IP Access Control Lists have been enabled on interface IP Access Control Lists have been disabled on interface IP has detected Port UP WAN devices only IP has detected Port DOWN WAN devices only IP Proxy ARP has been disabled on interface IP Proxy ARP has been enabled on interface IP RIP has been enabled on interface IP RIP has been disabled on interface IPX Event Log Change Trap Type Cod...

Страница 35: ...ly IPX RIP has been enabled on interface IPX RIP has been disabled on interface IPX SAP has been enabled on interface IPX SAP has been disabled on interface Software and Firmware Upgrades Software and Firmware upgrades can be performed remotely through the Windows based QuickSET utility application Refer to the QuickSET Configuration Guide for instructions QuickSET allows the user to retrieve or u...

Страница 36: ...Chapter 2 About the HSIM W6 2 22 HSIM W6 Installation Guide ...

Страница 37: ... to install it 3 Attach the antistatic wrist strap refer to the instructions on the antistatic wrist strap package 4 After removing the module from its non conductive bag visually inspect the device If there are any signs of damage contact Cabletron Systems refer to Chapter 1 Getting Help immediately Guidelines for Installations Installation sites must be within reach of the network cabling and me...

Страница 38: ...ling WAN Port Interface Modules WPIMs To install a WPIM into the HSIM W6 refer to Figure 3 1 and Figure 3 2 and complete the following steps 1 Attach the antistatic wrist strap to your wrist refer to the instructions on the antistatic wrist strap package 2 Remove and save the three screws from the WPIM standoffs see Figure 2 Remove the WPIM coverplate CAUTION The WPIMs and CSX COMP ENCR for the HS...

Страница 39: ...Figure 3 4 Carefully align and gently insert the WPIM connector onto the WPIM connector pins on the HSIM W6 5 Press down firmly on the WPIM until the pins slide all the way into the connector Ensure that the WPIM seats firmly on the standoffs 6 Secure the WPIM to the three standoffs using the screws that are provided with the HSIM W6 7 Reattach the faceplate to the HSIM using the two screws saved ...

Страница 40: ...atic wrist strap to your wrist and the other end to an approved electrical ground 2 Unpack the CSX COMP ENCR by carefully removing it from the shipping box and then from the protective plastic bag Do not cut the bag as the device could be damaged If there are any signs of damage contact the Cabletron Systems Global Call Center refer to Chapter 1 Getting Help WPIM Screws Standoffs WPIM Connector WP...

Страница 41: ...Lower the CSX COMP ENCR onto the standoffs and align the connector with the connector pins Carefully insert the connector pins of the CSX COMP ENCR into the connector on the HSIM W6 6 Press down firmly on the CSX COMP ENCR until the pins fit all the way into the connector 7 Secure the CSX COMP ENCR with the standoff screws supplied with the CSX COMP ENCR The CSX COMP ENCR installation is complete ...

Страница 42: ...ssis documentation for exact HSIM slot and connector locations Installing an HSIM in an Interface Module To install an HSIM in a module that supports HSIM technology refer to Figure 3 4 and Figure 3 5 and complete the following steps 1 Disconnect all network cables from the interface module Note the ports to which these cables are attached 2 Attach the disposable antistatic wrist strap 3 Unlock th...

Страница 43: ...nsert the connector pins of the HSIM into the HSIM connector on the interface module 9 Press down firmly on the back of the HSIM until the pins slide all the way into the connector holes 10 Secure the HSIM to the faceplate using the two screws saved in step 5 11 Secure the HSIM to the standoffs with the screws saved in step 6 12 Reinstall the interface module in the chassis 13 Reattach the network...

Страница 44: ...Installation 3 8 HSIM W6 Installation Guide Figure 3 5 Installing the HSIM Standoff Screws Faceplate Mounting Screws 225705 HSIM Connector Standoffs WIDE AREA 1 WIDEAREA2 ASYNC TELCO TELCO LNK STS LNK STS LNK STS ...

Страница 45: ...andoff screws See Figure 3 4 7 Place the HSIM behind the chassis faceplate See Figure 3 5 8 Ensure that the standoffs on the chassis align with the standoff screw holes on the HSIM to prevent bending the pins and insert the connector pins of the HSIM into the HSIM connector on the chassis motherboard 9 Press down firmly on the back of the HSIM until the pins slide all the way into the connector ho...

Страница 46: ...Chapter 3 Installation 3 10 HSIM W6 Installation Guide ...

Страница 47: ...are having difficulty installing and configuring the HSIM W6 perform the following steps Check that all cables and connectors have been attached properly Verify that power has been applied to the HSIM W6 Figure 4 1 HSIM W6 Front Panel LEDs Table 4 1 HSIM W6 Hardware LED States LED Color State Processor CPU OFF Power Off RED Fault condition detected AMBER Testing in progress GREEN Functional WIDE A...

Страница 48: ... Color State Status STS AMBER Console connection Data Carrier Detect DCD No Data Set Ready DSR AMBER blinking Test mode GREEN Modem with connection DCD DSR GREEN blinking Modem no connection DSR No DCD Link LNK RED or GREEN Modem connection Request To Send RTS No Clear To Send CTS AMBER blinking Traffic Modem or console connection Table 4 3 HSIM W6 ASYNC Console Connection Pinout PIN Description 1...

Страница 49: ... 4 Receive Data 5 Ground 6 Data Terminal Ready DTR 7 Request to Send RTS 8 Clear to Send CTS Table 4 5 HSIM W6 WAN Link LNK LED States LED Color State Link LNK OFF WAN interface not configured or not present RED No Link Connection Fault on the WAN interface AMBER Transmit TX and or receive RX traffic GREEN Link and port is active GREEN blinking Link and port is in standby ...

Страница 50: ... Port in test mode GREEN Request to send Table 4 7 HSIM W6 WAN Status STS LED States for DDS Ports LED Color State Status STS OFF Normal or disabled RED Not used AMBER Out of Service AMBER blinking Port in test mode GREEN Not used Table 4 8 HSIM W6 WAN Status STS LED States for SYNC Ports LED Color State Status STS OFF Normal or disabled RED Not used AMBER Not used AMBER blinking Port in test mode...

Страница 51: ...an unknown state Contact Cabletron Systems Global Call Center for technical support refer to Getting Help in Chapter 1 Table 4 9 HSIM W6 WAN Status STS LED States for HDSL Ports LED Color State Status STS OFF Normal or disabled RED One or both loops not synchronized AMBER Not used AMBER blinking Port in test mode GREEN Full both loops synchronized Fractional one lop synchronized Table 4 10 HSIM W6...

Страница 52: ...ing and console connection pinout Link LNK LED is AMBER There is traffic on the interface Status STS LED is OFF The ASYNC port is disconnected or Data Carrier Detect DCD and Data Set Ready DSR are inactive Status STS LED is AMBER The console connection is detected The Data Carrier Detect DCD is active while the Data Set Ready DSR is inactive If the port does not function check the cabling console ...

Страница 53: ...nt on the WAN interface Check that the HSIM W6 and the device at the other end of the segment are powered up Use QuickSET or Local Management to make sure that both WAN interfaces local and remote are configured correctly Check to ensure that the correct cable is being used Check to ensure that the cable has continuity and is fully installed Check with the WAN Service Provider to ensure that the c...

Страница 54: ...al Management to make sure that the WAN interface on the Local device is configured correctly WPIM HDSL Installed in HSIM W6 The port is disabled or has been placed into Loopback Test mode Use QuickSET or Local Management to make sure that the WAN interface on the Local device is configured correctly Use QuickSET or Local Management to make sure that the WAN interface on the Remote device is confi...

Страница 55: ...tions Category 3 or Category 5 Unshielded Twisted Pair copper wiring is required One pair 2 wires for Fractional T1 two pair 4 wires for Full T1 The presence of bridged taps and multiple wire segments connected together to form the loop may reduce the maximum distance usable between the Remote and Local devices Wire gauge has an impact on the distance which can be supported as well The maximum dis...

Страница 56: ...ED is GREEN WPIM SYNC Installed in HSIM W6 The Port is operating normally Request to Send RTS has been activated by your WAN device If it is not use the following steps Use QuickSET or Local Management to make sure that the WAN interface on the local device is configured properly Verify the cabling being used between the HSIM W6 and the CSU DSU WPIM HDSL is Installed in HSIM W6 The Port is operati...

Страница 57: ... the same IP subnetwork or the HSIM W6 must be reachable through a router on your LAN Check Network TCP IP properties under Windows 95 or Windows NT as described in the Read Me First document User Cannot Communicate with Remote Network Station If Bridging Check that the Bridging Default Destination is set Check that bridging to from the remote router is set on Be sure to reboot if you have made an...

Страница 58: ...ry other t391 cycle we sent out a LINK INTEGRITY VERIFICATION ENQUIRYmessage LIV We expect to get a LINK INTEGRITY VERIFICATION RESPONSE back from the Fr switch before out t391 polling cycle expires This is a keep alive message that does no more than let us know the link between us and the FR switch is still alive The information provided in a FULL STATUS RESPONSE or ASYNCHRONOUS STATUS MESSAGE ba...

Страница 59: ...tion for ordering a standard 20 foot cable or a specified length of cable The number 20 followed by the part number denotes the standard 20 foot cable The letter L denotes the specified length required in feet or meters For example 9372095 3 denotes a 3 foot cable 9372095 3M denotes a 3 meter cable Table A 1 T 1 Interface Cable Part Numbers Connector Type Part Number RJ48C 9372094 Table A 2 T 1 Co...

Страница 60: ...RJ48 network pin assignments Table A 3 DTE Pin Assignments Pin Signal 1 Receive Ring 2 Receive Tip 3 Not Used 4 Transmit Ring 5 Transmit Tip 6 Not Used 7 Shield Ground 8 Shield Ground Table A 4 Network Pin Assignments Pin Signal 1 Receive Ring 2 Receive Tip 3 Not Used 4 Transmit Ring 5 Transmit Tip 6 Not Used 7 Not Used 8 Not Used ...

Страница 61: ...bles Table A 5 provides the cable and interface types electrical types and part numbers for the WPIM SY Table A 5 WPIM SY Interface Cables Cable and Interface Type Electrical Type Part Number RS449 RS422 9380120 V 35 V 35 9380121 RS232 RS232 9380122 X 21 X 21 9380123 RS530 RS422 9380124 RS530 ALT A RS422 9380125 RS530A RS422 9380126 RS530A ALT A RS422 9380127 ...

Страница 62: ...RECT TO NAME PIN PIN NAME DIRECT TO MNEMONIC BA DCE Transmit Data A 2 A 4 Send Data A DCE SD Transmit Data B 14 22 Send Data B BB DTE Receive Data A 3 B 6 Receive Data A DTE RD Receive Data B 16 24 Receive Data B CB Clear to Send A 5 C 9 Clear to Send A CS Clear to Send B 13 27 Clear to Send B CA DCE Request to Send A 4 D 7 Request to Send A DCE RS Request to Send B 19 25 Request to Send B DB DTE ...

Страница 63: ...or Number Cable Assembly Description Connector Type 1 EIA 530A ALT A to V 35 Sub DB 26 pin male 2 M Series 34 pin male Table A 9 V 35 Interface Cable Pin Assignment Connector 1 EIA 530A ALT A PAIR Connector 2 V 35 MNEMONIC DIRECT TO NAME PIN PIN NAME DIRECT TO MNEMONIC BA DCE Transmit Data A 2 A P Transmit Data A DCE 103 Transmit Data B 14 S Transmit Data B BB DTE Receive Data A 3 B R Receive Data...

Страница 64: ...CE 113 Transmit Signal Timing B 11 W Transmitter Signal Timing B CE DTE Ring Indicator 22 J Calling Indicator DTE 125 TM Test Mode 25 NN Test Indicator 142 CC DCE Ready 6 E Data Set Ready 107 CD DCE DTE Ready 20 H Data Terminal Ready DCE 108 RL Remote Loopback 21 N Loopback Maintenance 140 LL Local Loopback 18 L Local Loopback 141 SHIELD 1 DRAIN AC Signal Common 23 B Signal Common 102 AB Signal Co...

Страница 65: ...ransmit Data 2 2 Transmit Data DCE BA BB DTE Receive Data 3 3 Receive Data DTE BB CB Clear to Send 5 5 Clear to Send CB CA DCE Request to Send 4 4 Request to Send DCE CA DB DTE Transmit Signal Timing 15 15 Transmitter Signal Timing DTE DB DD Receive Signal Timing 17 17 Receiver Signal Timing DD DA DCE Transmit Signal Timing 24 24 Transmitter Signal Timing DCE DA CE DTE Ring Indicator 22 22 Ring In...

Страница 66: ... A PAIR Connector 2 X 21 MNEMONIC DIRECT TO NAME PIN PIN NAME DIRECT TO MNEMONIC BA DCE Transmit Data A 2 A 2 Transmit A DCE T Transmit Data B 14 9 Transmit B BB DTE Receive Data A 3 B 4 Receive A DTE R Receive Data B 16 11 Receive B CB DTE Clear to Send A 5 C 5 Indication A DTE I Clear to Send B 13 12 Indication B CA DCE Request to Send A 4 D 3 Control A DCE C Request to Send B 19 10 Control B DB...

Страница 67: ... EIA 530A ALT A to EIA 530 ALT A Sub DB 26 pin male 2 Sub DB26 pin male 1 EIA 530A ALT A to EIA 530A Sub DB 26 pin male 2 DB 25 pin male 1 EIA 530A ALT A to EIA 530A ALT A Sub DB 26 pin male 2 Sub DB 26 pin male Table A 15 EIA 530 EIA 530 ALT A EIA 530A and EIA 530A ALT A Interface Cable Pin Assignments Connector 1 EIA 530A ALT A PAIR Connector 2 EIA 530 MNEMONIC DIRECT TO NAME PIN PIN NAME DIRECT...

Страница 68: ...pback 18 18 Local Loopback LL TM DTE Test Mode 25 25 Test Mode DTE TM CC DCE Ready 6 6 DCE Ready CC CD DCE DTE Ready 20 20 DTE Ready DCE CD SHIELD 1 DRAIN AC Signal Common 23 7 Signal Common AC a AC Signal Common 23 23 Signal Common AC AB Signal Common 7 7 Signal Common AB b CE DTE Ring Indicator 22 22 Ring Indicator DTE CE a This pin assignment only applies to the EIA 530A ALT A interface cable b...

Страница 69: ...e DDS circuit Table A 16 provides cable and interface type and part number information for the WPIM DDS interface cable and Table A 17 provides network Pin Assignment information for the DDS interface cable Table A 16 DDS Interface Cable Part Number Cable and Interface Type Part Number DDS 9360119 Table A 17 Network Pinout Assignments PIN SIGNAL 1 Transmit Ring 2 Transmit Tip 3 Not Used 4 Not Used...

Страница 70: ...tor number cable and interface type connector type and part number information Table A 19 provides WPIM E1 network interface cable pin assignments Table A 18 WPIM E1 Connector Information Connector Number Cable and Interface Type Connector Type Part Number 1 E1 RJ45 9372095 2 Table A 19 Network Interface Pin Signal 1 Receive Ring 2 Receive Tip 3 Shield Ground 4 Transmit Ring 5 Transmit Tip 6 Shiel...

Страница 71: ...45 network interface cable pin assignments Table A 20 DTE Interface Pin Signal 1 Receive Ring 2 Receive Tip 3 Shield Ground 4 Transmit Ring 5 Transmit Tip 6 Shield Ground 7 Not Used 8 Not Used Table A 21 Network Interface Pin Signal 1 Receive Ring 2 Receive Tip 3 Not Used 4 Transmit Ring 5 Transmit Tip 6 Not Used 7 Not Used 8 Not Used ...

Страница 72: ...r type and part number information for the WPIM DI interface Table A 23 provides the WPIM DI network interface cable pin assignments Table A 22 WPIM DI Connector Information Connector Number Cable Assembly Description Cable and Interface Type Connector Type Part Number 1 Network DI RJ48 9372094 2 Drop and Insert Table A 23 WPIM DI Network Pin Signal 1 Receive Ring 2 Receive Tip 3 AC Coupled Ground...

Страница 73: ...assignments for the RJ 45 network interface connector Table A 24 WPIM DI Drop and Insert Pin Signal 1 Transmit Ring 2 Transmit Tip 3 AC Coupled Ground 4 Receive Ring 5 Receive Tip 6 AC Coupled Ground 7 AC Coupled Ground 8 AC Coupled Ground Table A 25 WPIM HDSL Network Interface Cable Pin Assignments Pin Signal 1 HDSL Loop 1 Ring1 2 HDSL Loop 1 Tip1 3 Not Used 4 HDSL Loop 2 Ring2 5 HDSL Loop 2 Tip2...

Страница 74: ...ides connector specifications for the WPIM S T interface cable Table A 26 provides pin assignments for the RJ 45 network interface connector Table A 26 WPIM S T Network Interface Cable Pin Assignments Pin Signal 1 Not Used 2 Not Used 3 Transmit 4 Receive 5 Receive 6 Transmit 7 Not Used 8 Not Used ...

Страница 75: ...of UL 1950 CSA C22 2 No 950 and EN 60950 IEC 950 and 73 23 EEC Electromagnetic Compatibility EMC This unit meets the EMC requirements of FCC Part 15 EN 55022 EN 50082 1 89 336 EEC AS NZS 3548 CSA C108 8 and VCCI V 3 Table B 1 Hardware Specifications WAN Interface 2 WPIM ports Processor Intel i960 66 Mhz Power Supply 5V Supplied by host device Power Consumption 30 Watts maximum Operating Temperatur...

Страница 76: ... This unit meets the safety requirements of UL 1950 and CSA C22 2 No 950 Electromagnetic Compatibility EMC This unit meets the EMC requirements of FCC Part 15 VCCI V 3 and CSA C108 8 NEBS This unit meets a minimum of Level 1 NEBS requirements in accordance with Bellcore SR 3580 TELECOM FCC Part 68 CS 03 WPIM SY This section describes the environmental specifications and safety and approval require...

Страница 77: ...es the environmental specifications and safety and approval requirements for the WPIM E1 Safety This unit meets the safety requirements of EN 60950 IEC 950 73 23 EEC and AS NZS 3260 Electromagnetic Compatibility EMC This unit meets the EMI requirements of EN 55022 EN 50082 1 AS NZS 3548 and 89 336 EEC TELECOM 91 263 EEC CTR 12 TS 001 and TS 016 WPIM DI This section describes the environmental spec...

Страница 78: ... of FCC Part 15 EN 55022 VCCI V 3 CSA 08 8 EN 50082 1 AS NZS 3548 89 336 EEC Telcom Future FCC part 68 CS 03 WPIM HDSL This section describes the environmental specifications and safety and approval requirements for the WPIM HDSL Safety This unit meets the safety requirements of UC1950 CSA 22 2 No 950 EN 60950 IEC 950 73 23 EEC Electromagnetic Compatibility EMC This unit meets the EMC requirements...

Страница 79: ...ory Number 2 ISDN Switch Type System Settings Ethernet IP Address Ethernet IP Address and Subnet Mask System Settings Ethernet IPX Network Ethernet IPX Network Number Table C 2 Remote Router Configuration Section Item Setting Remote Router Database Dial Settings ISDN Phone 1 ISDN Phone 2 Disconnect Timer Value Maximum Links Minimum Links Threshold Bandwidth Direction Remote Router Database Securit...

Страница 80: ...Router Database IPX SAPs SAPs Server Name Server Type Network Number Node Number and Sockets WAN Network Number a Used only in PPP numbered mode of addressing b Used only in PPP numbered mode of addressing NOTE Make one chart for each remote router in the remote router database Table C 3 Bridging and Routing Controls Configuration Section Item Setting Bridging Routing Default Remote Bridging Desti...

Страница 81: ...cted to the network connected behind an FCC Part 68 registered channel service unit Direct connection is not allowed 2 Before connecting your unit you must inform the local telephone company of the following information Table D 1 WPIM DI and WPIM T1 Table D 2 WPIM DDS Only Table D 3 WPIM S T Only Port ID REN SOC FIC USOC WPIM DI WPIM T1 6 0N 04DU9 BN 04DU9 DN 04DU9 1KN 04DU9 1SN 04DU9 1ZN RJ48C RJ...

Страница 82: ...CC Rules no customer is authorized to repair this equipment This restriction applies regardless of whether the equipment is in or out of warranty 6 If the telephone company alters their equipment in a manner that will affect use of this device they must give you advance warning so as to give you the opportunity for uninterrupted service You will be advised of your right to file a complaint with th...

Страница 83: ...equipment to be connected complies with Part 68 of the Commission s rules except for the encoded analog content and billing protection specifications With respect to encoded analog content and billing protection I attest that all operations associated with the establishment maintenance and adjustment of the digital CPE with respect to encoded analog content and encoded billing information continuo...

Страница 84: ... or authorized representative using training materials and instructions provided by the manufacturer grantee of the equipment used to encode analog signals or c An independent training course e g trade school or technical institution recognized by the manufacturer grantee of the equipment used to encode analog signals or d In lieu of the proceeding training requirements the operator s maintainer s...

Страница 85: ... Kbps B channels for voice data and video transmission and one 16 Kbps D channel for signaling and data transmission Bridge A device that segments network traffic A bridge maintains a list of each node on the segment and only traffic destined for a node on the adjacent segment is passed across the bridge A bridge operates at Layer 2 of the OSI reference model CHAP Challenge Handshake Authenticatio...

Страница 86: ...rotect one network from unknown networks and users on the outside Firewalls can filter or block traffic and act as a management and network security point where all traffic can be scrutinized Frame A group of data generated by Data Link Layer operation Frame Relay Data Link Protocol that provides connectivity between one local and numerous remote connections HDSL High bit rate Digital Subscriber L...

Страница 87: ...ed by the IEEE 802 3 specification which defines media access including framing and error detection Part of the OSI reference model Data Link layer Metric An algorithm used by routers to determine the best path for transmitting packets to a remote destination based on considerations such as time delay cost etc Modem Modulator Demodulator A device that converts digital signals to from analog signal...

Страница 88: ...e node PPP Point to Point Protocol A Data Link layer protocol that provides asynchronous and synchronous connectivity between computer network nodes Includes standardization for security and compression negotiation Q 921 ISDN Data Link layer specification for the user to network interface Q 931 ISDN specification for call set up and signaling on ISDN connections Q 933 ITU Frame Relay Data Link Lay...

Страница 89: ... be used individually for a separate data connection Spoofing Spoofing is a technique used to remove poll and update service frames from WAN links while ensuring that the network continues to operate normally Spoofing is employed to minimize dial up line connection time Subnet Address An extension of the Internet 32 bit addressing scheme that allows the separation of physical or logical networks w...

Страница 90: ...that allows transfer of frames across intermediate nodes using tables associating end nodes with bridging addresses Bridges are unknown to the end nodes UDP User Datagram Protocol A connectionless protocol used to pass packets across an internet network requiring no handshaking between source and destination Watchdog Frames Frames sent out by servers to clients under IPX to verify that clients are...

Страница 91: ...irewall 2 17 IP routing 2 16 L LAN support 2 3 M MIB support 2 18 N Network information worksheets A 1 C 1 P PPP 2 4 R Remote Network Management 2 3 Remote router worksheet C 1 Routing 2 16 S Safety Requirements B 2 SNMP 2 18 SNMP Community Names read only 2 17 read write 2 18 super user 2 18 Software and firmware upgrades 2 21 Switch support 2 11 T Troubleshooting 4 1 bridging 4 11 power 4 5 soft...

Страница 92: ...Index Index 2 HSIM W6 Installation Guide ...

Отзывы: