Configuring the SMT Connection Policy
4-21
FDDI Management
Configuring the SMT Connection Policy
The SMT Connection Policy of an FDDI concentrator determines which types of
connections are allowed among the four FDDI port types: A, B, M (Master), and S
(Slave). FDDI protocol forbids Master—>Master connections; all other connection
types are legal, although some are considered to be undesirable.
To open the SMT Connection Policy window:
from the Hub View:
1.
Click either mouse button on any Module Index or Module Type text box to
display the Module Menu (remember, this menu is the same for all application
display modes).
2.
Drag down to FDDI Utilities, then across to select SMT Connection Policy.
from the command line (stand-alone mode):
1.
From the appropriate directory type:
spmarun fddicpol <IP Address> <community name>
NOTES
The spmarun script invoked first in the above command temporarily sets the environment
variables SPMA needs to operate; be sure to use this command any time you launch an
application from the command line. This script is automatically invoked when you launch
an application from within the Hub View.
If you wish to configure the connection policy, be sure to use a community name with at
least Read/Write access. If you only wish to view the policy, a community name with Read
access will be sufficient.
If there is a hostname mapped to your 7C0x’s IP address, you can use <hostname> in
place of <IP address> to launch this application. Please note, however, that the hostname
is not the same as the device name which can be assigned via Local Management and/or
SPMA; you cannot use the device name in place of the IP address.
Содержание 7C03 MMAC SmartSWITCH
Страница 2: ......
Страница 8: ...Contents vi...
Страница 56: ...Using the 7C0x SmartSwitch Hub View 2 40 Managing the Hub...
Страница 68: ...Basic Alarm Configuration 3 12 Viewing an Alarm Log...
Страница 96: ...FDDI Management 4 28 Viewing the Station List...
Страница 102: ...ATM Configuration 5 6 Configuring Connections...
Страница 111: ...Using the Detail View Window 6 9 Using the 7C0x SmartSwitch Bridge View Figure 6 3 Detail View Showing Four Ports...
Страница 140: ...Using the 7C0x SmartSwitch Bridge View 6 38 Enabling and Disabling Ports...
Страница 150: ...Index Index 6...