Using the 7C0x SmartSwitch Bridge View
6-18
The Filtering Database Window
Changing Forwarding and Static Database Entries
The only entries that can be changed or deleted in the Filtering Database are static
entries. If the entry you wish to change or delete is a forwarding entry, you must
add it to the Static Table. The Static Table (
Figure 6-9
) is used to change a
forwarding entry to a static or permanent entry, or make changes to existing static
entries. To open the Static Table window:
1.
Open the Filtering Database window by clicking on the Front Panel
button; drag down to Filtering Database to display the Filtering Database
window.
2.
If the Filtering Database window displays Forwarding entries, highlight the
entry you want to change and click on the Add to Static Table button.
or
If the Filtering Database window displays Static entries, highlight an entry and
click on the Change button.
Figure 6-9. Static Table Window
NOTE
It is also possible to open the Static Table in either case without highlighting an entry, by
clicking on the Add To Static Table button. The static address field will appear blank.
Enter the MAC address that you want to add to the Static Table.
Содержание 7C03 MMAC SmartSWITCH
Страница 2: ......
Страница 8: ...Contents vi...
Страница 56: ...Using the 7C0x SmartSwitch Hub View 2 40 Managing the Hub...
Страница 68: ...Basic Alarm Configuration 3 12 Viewing an Alarm Log...
Страница 96: ...FDDI Management 4 28 Viewing the Station List...
Страница 102: ...ATM Configuration 5 6 Configuring Connections...
Страница 111: ...Using the Detail View Window 6 9 Using the 7C0x SmartSwitch Bridge View Figure 6 3 Detail View Showing Four Ports...
Страница 140: ...Using the 7C0x SmartSwitch Bridge View 6 38 Enabling and Disabling Ports...
Страница 150: ...Index Index 6...