background image

x

DECLARATION OF CONFORMITY

Application of Council Directive(s):

89/336/EEC
73/23/EEC

Manufacturer’s Name:

Cabletron Systems, Inc.

Manufacturer’s Address:

35 Industrial Way
PO Box 5005

Rochester, NH 03867

European Representative Name:

Mr. J. Solari

European Representative Address:

Cabletron Systems Limited
Nexus House, Newbury Business Park
London Road, Newbury

Berkshire RG14 2PZ, England

Conformance to Directive(s)/Product Standards:

EC Directive 89/336/EEC
EC Directive 73/23/EEC
EN 55022
EN 50082-1

EN 60950

Equipment Type/Environment:

Networking Equipment, for use in a Commercial 
or Light Industrial Environment.

We the undersigned, hereby declare, under our sole responsibility, that the equipment packaged with this 
notice conforms to the above directives.

Manufacturer

Legal Representative in Europe

Mr. Ronald Fotino

Mr. J. Solari

___________________________________

___________________________________

Full Name

Full Name

Compliance Engineering Manager

Managing Director - E.M.E.A.

___________________________________

___________________________________

Title

Title

Rochester, NH, USA

Newbury, Berkshire, England

___________________________________

___________________________________

Location

Location

Содержание 6E233-49 SmartSwitch 6000

Страница 1: ... 16X 10X 12X 9 10 11 12 14 13 15 16 17 18 19 20 21 22 23 24 18X 20X 22X 24X 2X 4X 6X 8X 1 2 3 4 5 6 7 8 6H262 18 FAST ENET DPX SPD RX TX LED MODE 2X 4X 6X 8X 1 2 3 4 5 6 7 8 14X 16X 10X 12X 9 10 11 12 14 13 15 16 G P I M 1 G P I M 2 COM CPU RESET 6H252 17 FAST ENET DPX SPD RX TX COM RESET CPU 2X 4X 6X 8X 1 2 3 4 5 6 7 8 14X 16X 10X 12X 9 10 11 12 14 13 15 16 ...

Страница 2: ......

Страница 3: ...O LOST PROFITS ARISING OUT OF OR RELATED TO THIS MANUAL OR THE INFORMATION CONTAINED IN IT EVEN IF CABLETRON SYSTEMS HAS BEEN ADVISED OF KNOWN OR SHOULD HAVE KNOWN THE POSSIBILITY OF SUCH DAMAGES Cabletron Systems Inc 35 Industrial Way Rochester NH 03866 5005 2000 by Cabletron Systems Inc All Rights Reserved Printed in the United States of America Order Number 9033378 January 2000 Cabletron System...

Страница 4: ...ase the user will be required to correct the interference at his own expense WARNING Changes or modifications made to this device which are not expressly approved by the party responsible for compliance could void the user s authority to operate the equipment INDUSTRY CANADA NOTICE This digital apparatus does not exceed the Class A limits for radio noise emissions from digital apparatus set out in...

Страница 5: ... of the Program provided in this package subject to the terms and conditions of this License Agreement You may not copy reproduce or transmit any part of the Program except as permitted by the Copyright Act of the United States or as authorized in writing by Cabletron 2 OTHER RESTRICTIONS You may not reverse engineer decompile or disassemble the Program 3 APPLICABLE LAW This License Agreement shal...

Страница 6: ...e submitted with restricted rights in accordance with section 52 227 19 a through d of the Commercial Computer Software Restricted Rights Clause and its successors and iii in all respects is proprietary data belonging to Cabletron and or its suppliers For Department of Defense units the Product is considered commercial computer software in accordance with DFARS section 227 7202 3 and its successor...

Страница 7: ...t to regulation by agencies of the U S Government including the U S Department of Commerce which prohibit export or diversion of certain technical products to certain countries unless a license to export the product is obtained from the U S Government or an exception from obtaining such license may be relied upon by the exporting party If the Program is exported from the United States pursuant to ...

Страница 8: ...ocumentation and media CABLETRON DISCLAIMS ALL WARRANTIES OTHER THAN THOSE SUPPLIED TO YOU BY CABLETRON IN WRITING EITHER EXPRESS OR IMPLIED INCLUDING BUT NOT LIMITED TO IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE WITH RESPECT TO THE PROGRAM THE ACCOMPANYING WRITTEN MATERIALS AND ANY ACCOMPANYING HARDWARE 7 NO LIABILITY FOR CONSEQUENTIAL DAMAGES IN NO EVENT SHALL CAB...

Страница 9: ...the right to use only the one 1 copy of the Program provided in this package subject to the terms and conditions of this License Agreement You may not copy reproduce or transmit any part of the Program except as permitted by the Copyright Act of the United States or as authorized in writing by Cabletron 2 OTHER RESTRICTIONS You may not reverse engineer decompile or disassemble the Program 3 APPLIC...

Страница 10: ...re submitted with restricted rights in accordance with section 52 227 19 a through d of the Commercial Computer Software Restricted Rights Clause and its successors and iii in all respects is proprietary data belonging to Cabletron and or its suppliers For Department of Defense units the Product is considered commercial computer software in accordance with DFARS section 227 7202 3 and its successo...

Страница 11: ...tandardization When operating within their performance limitations laser transceiver output meets the Class 1 accessible emission limit of all three standards Class 1 levels of laser radiation are not considered hazardous SAFETY INFORMATION CLASS 1 LASER TRANSCEIVERS LASER RADIATION AND CONNECTORS When the connector is in place all laser radiation remains within the fiber The maximum amount of rad...

Страница 12: ...N 60950 Equipment Type Environment Networking Equipment for use in a Commercial or Light Industrial Environment We the undersigned hereby declare under our sole responsibility that the equipment packaged with this notice conforms to the above directives Manufacturer Legal Representative in Europe Mr Ronald Fotino Mr J Solari ___________________________________ ___________________________________ F...

Страница 13: ... 5 SmartTrunk 1 4 1 1 6 Remote Monitoring RMON 1 4 1 1 7 Broadcast Suppression 1 5 1 1 8 Port VLAN Redirect Functions 1 5 1 1 9 Rate Limiting 1 5 1 1 10 GARP Switch Operation 1 6 1 1 11 Flow Control 1 6 1 1 12 802 1 Port Priority 1 6 1 1 13 Management 1 7 1 1 14 Switching Options 1 7 1 1 15 Distributed Chassis Management 1 7 1 1 16 Optional HSIMs and VHSIMs 1 7 1 1 17 Optional GPIMs 1 8 1 1 18 Sta...

Страница 14: ...s 3 5 3 6 Installing GPIMs 3 8 3 7 GPIM Network Connections 3 10 3 7 1 GPIM 09 Connection Using Multimode Cable 3 11 3 7 2 Connecting the GPIM 3 12 3 8 Completing the Installation 3 14 4 TROUBLESHOOTING 4 1 Using LANVIEW 4 1 4 1 1 The LED Mode Switch 4 2 4 2 GPIM LED Descriptions for the 6H262 18 4 6 4 3 Redundancy 4 7 4 4 Troubleshooting Checklist 4 8 4 5 Using the RESET Button 4 12 A SPECIFICATI...

Страница 15: ...cifications 1000Base LX B 2 B 2 Physical and Environmental Specifications B 2 B 3 Regulatory Compliance B 3 C SWITCH SETTINGS UPGRADES AND INSTALLATIONS C 1 Setting the Mode Switches C 1 C 2 SIMM Upgrade C 3 C 2 1 Locating SIMMs C 3 C 2 2 Installing the DRAM SIMM C 4 C 3 Installing Optional High Speed Interface Modules C 5 INDEX ...

Страница 16: ...Connector 3 8 3 6 Installing a GPIM into the 6H262 18 3 9 3 7 Fiber Optic Port Designations 3 10 3 8 GPIM 09 Launch Mode Conditioning Cable Connection 3 11 3 9 Fiber Optic GPIM Connections 3 13 3 10 6H262 18 with Two Fiber Optic GPIM Ports 3 14 4 1 LANVIEW LEDs 4 3 4 2 LANVIEW LEDs for the GPIM 4 6 4 3 Reset Button 4 12 C 1 Module Mode Switch Location Component Layout C 2 C 2 SIMM Slot Locations C...

Страница 17: ...r System Troubleshooting 4 9 4 6 Firmware Troubleshooting 4 10 4 7 Management System Troubleshooting 4 10 4 8 Device Setup Troubleshooting 4 11 A 1 COM Port Pin Assignments A 3 B 2 GPIM 01 Operating Range B 1 B 1 GPIM 01 Optical Specifications B 1 B 3 GPIM 09 Optical Specifications B 2 B 4 GPIM 09 Operating Range B 2 B 5 GPIM Physical Properties B 2 B 6 GPIM Environmental Requirements B 2 B 7 GPIM...

Страница 18: ...xvi ...

Страница 19: ...IDE Read through this guide completely to understand the SmartSwitch module features capabilities and Local Management functions A general working knowledge of Fast Ethernet and IEEE 802 3 type data communications networks and their physical layer components is helpful when using these devices Important Notice Depending on the firmware version used in the SmartSwitch some features described in thi...

Страница 20: ...martSwitches into the 6C105 SmartSwitch 6000 chassis Chapter 3 Installation provides instructions on how to install a module in the chassis and connect segments Chapter 4 Troubleshooting describes the SmartSwitch LANVIEW LEDs that enable quick diagnosis of network operational problems Appendix A Specifications contains information on functionality and operating specifications connector pinouts env...

Страница 21: ...M F6 User s Guide HSIM FE6 User s Guide HSIM W6 User s Guide HSIM W84 User s Guide HSIM W87 User s Guide HSIM G01 G09 User s Guide VHSIM G6 User s Guide VHSIM A6DP User s Guide WAN Series Local Management User s Guide VHSIM A6DP User s Guide The HSIM W6 Installation Guide the HSIM W84 Installation Guide and the WAN Series Local Management User s Guide are included on the QuickSET CD ROM and along ...

Страница 22: ...n to any item of information that may be of special importance TIP Tip symbol Conveys helpful hints concerning procedures or actions CAUTION Caution symbol Contains information essential to avoid damage to the equipment Electrical Hazard Warning symbol Warns against an action that could result in personal injury or death due to an electrical hazard ...

Страница 23: ...inks to networking technologies such as Gigabit Ethernet Fast Ethernet Fiber Distributed Data Interface FDDI Wide Area Network WAN and Asynchronous Transfer Mode ATM Some HSIMs can provide additional Fast Ethernet ports in varying media types The optional VHSIMs provide very high speed uplinks to networking technologies such as ATM and Gigabit Ethernet The optional GPIMs provide connectivity to Gi...

Страница 24: ... SPD RX TX LED MODE 2X 4X 6X 8X 1 2 3 4 5 6 7 8 14X 16X 10X 12X 9 10 11 12 14 13 15 16 G P I M 1 G P I M 2 COM CPU RESET 6H252 17 FAST ENET DPX SPD RX TX COM RESET CPU 2X 4X 6X 8X 1 2 3 4 5 6 7 8 14X 16X 10X 12X 9 10 11 12 14 13 15 16 System LED COM Port System LED COM Port LED Mode Switch Network Ports 1 16 Network Ports 1 16 Port Status LEDs Port Status LEDs VHSIM HSIM Slot LED Mode Switch LED M...

Страница 25: ...ilities are The Auto Negotiation feature targets the maximum capabilities that can be reached between the two devices For example the SmartSwitches adjust to 100 Mbps when the device on the other end of the connection can also adjust between 10 Mbps or 100 Mbps If the device on the other end of the connection can only operate at 10 Mbps then the SmartSwitches adjust to 10 Mbps operation When Auto ...

Страница 26: ...technology together to scale the backbone bandwidth beyond the limitations of a single link All links are user configurable so administrators can scale the backbone bandwidth by adding SmartTrunk links The benefits of SmartTrunking include the following All purchased bandwidth is used Distributed resilient links increase reliability and performance Multiple technologies are supported within a sing...

Страница 27: ...rating as an 802 1Q switch Multiple VLANs can be directed to the same ports 1 1 9 Rate Limiting The Rate Limiting feature enables the SmartSwitch device to have control of traffic rates on a per port per priority basis The network administrator can configure a rate limit from 100 kbps to 1 Gbps for a given port with an associated list of IEEE 802 1p priorities which can include one some or all of ...

Страница 28: ... flow of frames between two devices It ensures that a transmitting device does not overwhelm a receiving device with data This enables the receiving device to communicate with the transmitting device and to have it pause its transmission while the receiving device processes the frames already received Both devices must support the IEEE 802 3x standard for flow control to work The SmartSwitches sup...

Страница 29: ...ding any optional HSIM VHSIM or GPIM In the 802 1Q mode the default mode of operation the switch functions as an 802 1D switch until VLANs are configured SecureFast switching and IEEE 802 1Q switching allow migration to Virtual Network technologies without requiring the replacement of existing equipment 1 1 15 Distributed Chassis Management From a management perspective the 6C105 SmartSwitch 6000 ...

Страница 30: ... 6H262 18 are Gigabit Ethernet modules and are compliant with IEEE 802 3z The modules provide IEEE 802 1D Spanning Tree Algorithm STA support to enhance the overall reliability of the network and protect against loop conditions A wide variety of industry standard MIBs are supported by the modules including RFC 1213 MIB II RFC 1757 RMON RFC 1493 Bridge MIB RFC 1354 FIB MIB and RFC 1190 Path MTU Dis...

Страница 31: ...ion of any action s already taken to resolve the problem e g changing mode switches rebooting the unit etc The serial and revision numbers of all involved Cabletron Systems products in the network A description of your network environment layout cable type etc Network load and frame size at the time of trouble if known The device history i e have you returned the device before is this a recurring ...

Страница 32: ......

Страница 33: ...network performance 2 1 SmartTrunk To connect the SmartSwitch modules to a network so they can take advantage of the SmartTrunk feature there are certain rules concerning port connections and configurations that must be followed for proper operation For information on SmartTrunk configuration refer to the Cabletron Systems SmartTrunk User s Guide 2 2 10BASE T NETWORK When connecting a 10BASE T seg...

Страница 34: ... device at the other end of the fiber optic connection must meet the necessary 1000BASE SX or LX specification requirements for the devices to operate at 1 Gbps Refer to for cable specifications and Section 3 6 for installation instructions NOTE If a port is to operate at 100 Mbps Category 5 cabling must be used For 10 Mbps operation only Category 3 cabling can be used Refer to Section 2 3 for inf...

Страница 35: ... Chassis Section 3 4 Connecting to the Network Section 3 5 Installing GPIMs Section 3 6 GPIM Network Connections Section 3 7 Completing the Installation Section 3 8 Only qualified personnel should install the SmartSwitch modules NOTE Read the Release Notes shipped with the device to check for any exceptions to the supported features and operation documented in this guide ...

Страница 36: ... or after the 6H262 18 is installed in the 6C105 chassis The GPIMs are hot swappable and therefore may also be installed even when the module has power applied Refer to Section 3 6 for installation and connecting the network to any optional GPIMs 3 4 INSTALLING THE MODULE INTO THE 6C105 CHASSIS The SmartSwitches can be installed in any of the 5 slots that are available To install a module refer to...

Страница 37: ...e from the shipping box Save the box and packing materials in the event the module must be reshipped 3 Locate the antistatic wrist strap shipped with the 6C105 chassis Attach the antistatic wrist strap to your wrist and plug the cable from the antistatic wrist strap into the ESD grounding receptacle at the upper right corner of the 6C105 4 Remove the module from the plastic bag Save the bag in the...

Страница 38: ... NOT install the module Immediately contact the Cabletron Systems Refer to Section 1 2 for details 1 2 3 4 5 PS1 PS2 Plastic Locking Tab Slot Number 2361 02 2159 01 Circuit Card Card Guides Metal Back Panel Plastic Locking Tab Backplane Connector 1 2 14 13 COM CPU 3 4 5 6 7 8 9 10 11 12 15 16 6E252 17 Fast Enet 100 FDX RX TX 2X 4X 6X 8X 10X 12X 14X 16X RESET ...

Страница 39: ... 100 ports with internal crossovers When connecting a workstation use a straight through cable When connecting networking devices such as another bridge repeater or router use a crossover cable Connect a twisted pair segment to the SmartSwitch as follows 1 Ensure that the device connected to the other end of the segment is powered ON CAUTION To prevent damaging the backplane connectors in the foll...

Страница 40: ...id green If the RX LED is OFF and the TX Transmit LED is not blinking amber perform the following steps until it is on a Verify that the LED mode switch located near the COM port of the module is in the UP position RX and TX LED indicators b Verify that the cabling being used is Category 5 UTP with an impedance between 85 and 111 ohms If the port is to operate at 100 Mbps category 5 cabling must b...

Страница 41: ...connection meets the dB loss and cable specifications outlined in the Cabletron Systems Cabling Guide Refer to the About This Guide preface for information on obtaining this document If a link is not established contact Cabletron Systems Refer to Section 1 2 for details 4 Repeat steps 1 through 3 above until all connections have been made TX TX RX RX 2 1 3 6 TO Other Device Port TX TX 2 1 3 6 NOTE...

Страница 42: ...e packaging 3 Hold the GPIM with the network connection port facing away from the 6H262 18 The 20 pin connector should be facing towards the empty GPIM slot with the wide part of the connector oriented with the wide part of the receiving connector SeeFigure 3 5 to orient the GPIM 20 pin connector Figure 3 5 GPIM Connector NOTE The GPIMs are hot swappable therefore they can be installed into the 6H...

Страница 43: ...k the orientation against Figure 3 5 Push the GPIM back until the 20 pin port engages the GPIM The latch mechanism engages when the GPIM connector seats properly in the port Figure 3 6 Installing a GPIM into the 6H262 18 To remove a GPIM from the 6H262 18 squeeze both locking tabs in towards the center of the GPIM and pull it out of the port Network Port 20 pin Connector insertion end Locking Tab ...

Страница 44: ...e GPIM 01 and GPIM 09 both have the same type of SC fiber optic connector the directions for connectivity are the same except for when the GPIM 09 is connected to multimode fiber Refer to Section 3 7 1 before connecting the GPIM 09 to multimode fiber optic cable Different size and wavelength fiber optic cable is used for different applications The GPIM 09 typically has a blue connector to indicate...

Страница 45: ...d between like devices so that the transmit port of one device is connected to the receive port of the other device and vice versa If the fiber optic cable being used has SC style connectors that do not resemble MIC style connectors or has SC connectors on one end and a different type on the other such as ST connectors ensure that the proper cable cross over occurs NOTE When using multimode fiber ...

Страница 46: ...iber optic cable refer to Section 3 7 1 before following this procedure CAUTION The GPIM 01 and GPIM 09 use Class 1 lasers Do not use optical instruments to view the laser output The use of optical instruments to view laser output increases eye hazard When viewing the output optical port power must be removed from the network adapter NOTE Leave the protective covers in place when the connectors or...

Страница 47: ...OFF and the Transmit LED is not blinking amber perform the following steps until it is ON a Check that the device at the other end of the link is Gigabit Ethernet compatible and has power turned on b Verify proper crossover of fiber optic strands between the port on the GPIM and the fiber optic device at the other end of the fiber optic link segment c Verify that the fiber optic connection meets t...

Страница 48: ...Ds for troubleshooting before contacting Cabletron Systems Refer to Refer to Section 1 2 for details if the problem persists 3 8 COMPLETING THE INSTALLATION After installing the SmartSwitch and any optional HSIM VHSIM or GPIM the module is ready to be set up through Local Management For information on the Local Management connection configuring the 6C105 chassis and module and using Network Tools ...

Страница 49: ...ystem called LANVIEW The LANVIEW LEDs Figure 4 1 allow quick observation of the network status to aid in diagnosing network problems Refer to Table 4 1 for a description of the LEDs Refer to the HSIM or VHSIM User s Guide for a description of the HSIM or VHSIM LEDs Refer to Section 4 2 for the GPIM LED descriptions NOTE The terms flashing blinking and solid used in the LED definition tables of thi...

Страница 50: ...e the receive RX and transmit TX status of the fixed ports When the mode switch is in the DOWN position the LEDs indicate at what speed the applicable port is currently operating 10 Mbps or 100 Mbps and if the applicable port is operating in standard or full duplex mode Table 4 1 provides the definitions of the LED states that occur when the LED mode switch is in the UP position Table 4 2 provides...

Страница 51: ...2X 14X 16X DPX SPD RX TX LED Mode Switch DPX SPD RX TX DPX SPD RX TX LED MODE Mode Switch in UP Position Mode Switch in DOWN Position RESET A B B A LED functions when LED MODE switch is in the RX TX position This is the default switch setting LED functions when LED MODE switch is in the DPX SPD position Speed Status Full Duplex Status Receive RX Transmit TX ...

Страница 52: ...stems Solid Testing If the LED remains amber for several minutes contact Cabletron Systems Green Solid Functional None Amber and Green Booting Blinks amber and green while booting None The following port RX and TX LED indications are only valid when the LED MODE switch is in the RX TX position RX Off No link No activity or port in Standby Port enabled or disabled None Green Solid Port enabled link...

Страница 53: ...ent User s Guide for information on enabling disabling ports 2 Contact Cabletron Systems Red Flashing Indicates collision rate None unless there is a high rate of activity If so check for network configuration problems or a defective device Solid Diagnostic Failure Contact Cabletron Systems LED Color Description The following port DPX and SPD LED indications are only valid when the LED MODE switch...

Страница 54: ...LED Descriptions for the 6H262 18 4 6 Troubleshooting 4 2 GPIM LED DESCRIPTIONS FOR THE 6H262 18 Figure 4 2 LANVIEW LEDs for the GPIM 2549_02 Receive RX G P I M 1 G P I M 2 Transmit TX Receive RX Transmit TX ...

Страница 55: ...olor Definition The following port RX and TX LED indications are only valid when the LED MODE switch is in the RX TX position Transmit Green Flashing Activity port enabled Amber Blinking Port in standby Off No activity port enabled Red Flashing Transmit fault Red Diagnostic failure Receive Green Solid Link no activity Port enabled Green Blinking Link port disabled Amber Flashing Link activity Port...

Страница 56: ...otP server on the network Press the RESET button on the front panel to attempt to use the firmware image in FLASH memory 2 If the problem continues after pressing the RESET button refer to Section C 1 for instructions on forcing a BootP image download 3 Contact Cabletron Systems if the problem continues Cannot access Local Management 1 Firmware image fault refer to Table 4 6 2 Management system fa...

Страница 57: ...ther free slot in the chassis 2 If the module functions in the selected slot the module s onboard power converter is operational The 6C105 chassis power bus may have a localized fault Install the module in the working slot and contact Cabletron Systems 3 If the module does not function in the selected slot continue the process with all module slots in the chassis If the module does not function in...

Страница 58: ...tructions on how to force a download of a new firmware image 2 Contact Cabletron Systems if the problem continues Table 4 7 Management System Troubleshooting Possible Causes Instruction ImproperCommunityNamesT able 1 Refer to your Local Management User s Guide for Community Names Table setup 2 If the Community Names have been forgotten refer to Section C 1 for instructions on clearing NVRAM The mo...

Страница 59: ...tered parameters to reset to factory default settings 1 Reenter the lost parameters as necessary Refer to your Local Management User s Guide for instructions on configuring the device through Local Management 2 Call Cabletron Systems if the problem continues Clear NVRAM was set through Local Management 1 Reenter the lost parameters as necessary Refer to your Local Management User s Guide for instr...

Страница 60: ...ocessor goes through a reset process of approximately 60 seconds Additional downtime may be added as the module reenters the network CAUTION Pressing the RESET button resets the device and all current switching being performed by the module is halted A module downtime of up to two minutes results from this action NOTE It is not recommended to press the reset button while the module is already in r...

Страница 61: ...ONS A 2 PHYSICAL PROPERTIES A 3 ENVIRONMENTAL REQUIREMENTS Processors Intel i960 RISC processor control Power PC Dynamic Random Access Memory DRAM 20 MB FLASH Memory 8 MB Shared Memory 4MB Dimensions 46 43 H x 6 05 W x 29 51 D cm 18 28 H x 2 38 W x 11 62 D in Weight Unit 2 72 kg 6 lb MTBF Predicted 200 000 hours Operating Temperature 5 C to 40 C 41 F to 104 F Storage Temperature 30 C to 73 C 22 F ...

Страница 62: ...ace Module HSIM or Very High Speed Interface Module VHSIM Slot accepts optional HSIMs or VHSIMs that provide a variety of physical cabling types Ports 1 through 24 Fast Ethernet 10 100 Mbps 100BASE TX compliant with RJ45 connectors Ports 1 through 16 Fast Ethernet 10 100 Mbps 100BASE TX compliant with RJ45 connectors 2 slots for optional Gigabit Ethernet Port Interface Module GPIM Slots accept opt...

Страница 63: ...ic compatibility EMC requirements Table A 1 COM Port Pin Assignments Pin Signal Name Input Output 1 Transmit Data XMT Output 2 Data Carrier Detect DCD Output 3 Data Set Ready DSR Input 4 Receive Data RCV Input 5 Signal Ground GND NA 6 Data Terminal Ready DTR Output 7 Request to Send RTS Input 8 Clear to Send CTS NA Safety UL 1950 CSA C22 2 No 950 73 23 EEC EN 60950 IEC 950 Electromagnetic Compatib...

Страница 64: ......

Страница 65: ...d the GPIM 09 supports both multimode and single mode SMF fiber optic cable B 1 GIGABIT ETHERNET SPECIFICATIONS The following specifications for the Gigabit Ethernet GPIMs meet or exceed the IEEE 802 3z specification B 1 1 GPIM 01 Specifications 1000Base SX Table B 2 GPIM 01 Operating Range Table B 1 GPIM 01 Optical Specifications 62 5 µm MMF 50 µm MMF Transmit Power minimum 9 5 dBm 9 5 dBm Receiv...

Страница 66: ...minimum 11 5 dBm 11 5 dBm 9 5 dBm Receive Sensitivity 20 dBm 20 dBm 20 dBm Link Power Budget 8 5 dBm 8 5 dBm 10 5 dBm Table B 4 GPIM 09 Operating Range Modal Bandwidth 1300 nm Range 62 5 µm MMF 500 MHz km 2 550A Meters 50 µm MMF 400 MHz km 2 550A Meters 50 µm MMF 500 MHz km 2 550A Meters 10 µm SMF N A 2 10000 Meters Table B 5 GPIM Physical Properties Dimensions 1 2 H x 3 4 W x 6 5 D cm 0 47 H x 1 ...

Страница 67: ... COMPLIANCE The GPIMs meet the following safety and electromagnetic compatibility EMC requirements Table B 7 GPIM Safety and EMC Requirements Eye Safety fiber optic GPIMs only FDA CDRH 21 CFR 1040 Class 1 IEC 825 Issue 1 1993 11 Class 1 CENELEC EN 60825 Class 1 ...

Страница 68: ......

Страница 69: ...tered parameters such as the IP address and Subnet Masks to the SmartSwitch Default configuration settings Clear user entered passwords stored in NVRAM and restore the default passwords Figure C 1 shows the location of the mode switches and the switch settings for normal operation CAUTION You need an antistatic wrist strap provided with 6C105 chassis to perform the procedures in this appendix Use ...

Страница 70: ...tP server after power to the chassis is restored After changing the position of switch 6 and restarting the module the SmartSwitch requests a new image download until they either receive a new image or the RESET button on the front panel is pressed When the RESET button is pressed the SmartSwitch continues trying to contact a BootP server but will time out in approximately one minute If the module...

Страница 71: ...grade is available for the SmartSwitch modules to expand the DRAM to 32 MB This section explains how to locate and add replace a Single In line Memory Module SIMM For information on the available SIMM upgrades contact Cabletron Systems For details on getting help refer to Section 1 2 for details C 2 1 Locating SIMMs Figure C 2 shows the location of the DRAM SIMM connector Figure C 2 SIMM Slot Loca...

Страница 72: ...Figure C 3 insert the SIMM down between the connector teeth 2 Pivot the SIMM downward so the connector clips align with the two side notches of the SIMM and the connector clips lock the SIMM into place Figure C 3 Installing the DRAM CAUTION Observe all antistatic precautions when handling sensitive electronic equipment 1 2 SIMM Alignment Notch Clip Clip Connector Teeth Side Notch Side Notch Connec...

Страница 73: ...hows the location of the two connectors for an optional High HSIM or VHSIM Depending on if an HSIM or VHSIM is installed one or both connectors are used Figure C 4 HSIM and VHSIM Connector Locations NOTE Refer to the installation instructions for the optional HSIM or VHSIM in the associated user s guide Optional HSIM or VHSIM DRAM HSIM VHSIM Connectors 3378_C3 ...

Страница 74: ......

Страница 75: ... Chassis Management 1 7 Document Conventions xx E Environmental requirements A 1 H Help 1 9 related manuals xix I Installation connecting to the Network 3 5 High Speed Interface Module C 5 Module 3 1 Very High Speed Interface Module C 5 L LANVIEW LEDs 4 1 LDRAM installation C 4 Local Management introduction 1 7 M Memory upgrading C 3 Mode Switch Bank Settings C 1 N NVRAM clearing C 2 P Physical pr...

Страница 76: ...button 4 12 Runtime IP Address Discovery 1 3 S Safety A 3 Safety information laser ix SDRAM installation C 4 SIMMs installing LDRAM C 4 location C 3 SmartTrunk introduction 1 4 Specifications A 1 Standards compatibility 1 8 T Troubleshooting 4 1 checklist 4 8 U Unpacking 3 2 V VLAN Redirect Function introduction to 1 5 ...

Отзывы: