Chapter 5: Local Management
Page 5-28
2H22-08R SmartSwitch 2208 User’s Guide
2.
Press the SPACE bar to choose either ENABLED or DISABLED.
ENABLED allows the COM port to be connected to the terminal and
used for a particular application. DISABLED disallows the COM port
connection to the terminal.
!
CAUTION
Do NOT disable or alter the settings of the COM port while
operating the current Local Management connection through a
terminal. Altering the COM port settings disconnects the Local
Management terminal from the port, and ends the Local
Management session. If the 2H22-08R was previously
assigned a valid IP address, reenter Local Management by
establishing a Telnet connection to the device. If the device
does not have a valid IP address and the COM port has been
disabled or the settings changed, reset NVRAM on the
2H22-08R (refer to
Section 5.7.11
) to reestablish COM port
communications.
!
CAUTION
If the COM port is reconfigured without a valid IP address set
on the device, the message shown in
Figure 5-13
displays.
Do not continue unless the outcome of the action is fully
understood.