Model 64/64x2 Instruction Manual
Page 21
ERROR LIST
This test requires hookup of the optional printer (in accordance with the Printer Hookup
procedure in the Preparation section). When ERROR LIST is selected, Model 64 performs a
single test and the printer prints a list of errors encountered, or it prints "Passed" when there are
no errors. Sample error lists are shown in Figure 7. To select and use ERROR LIST, proceed as
follows:
1.
Verify printer is connected and its On Line light is on.
2.
Load program to be used (refer to Loading a Program procedure).
3.
Install harness to be tested.
4.
Press ERROR LIST. The Model 64 will perform a single test and will print a list
of all errors, or it will print "Passed 0001/0001" if there are no errors.
5.
When test and printouts are finished, disconnect harness.
ERROR LIST WITH TESTER POINTS:
Signature: 010066
* Error List *
Condition
From Point
To Point
OPEN
003
012
OPEN
001
010
OPEN
008
016
SHORT
003
010
SHORT
008
012
Failed 0000/0001
ERROR LIST WITH USER LABELS:
Signature: 010066
* Error List *
Condition
From Point
To Point
OPEN
J1-3
P1-3
OPEN
J1-1
P1-1
OPEN
J1-8
E2
SHORT
J1-3
P1-1
SHORT
J1-8
P1-3
Failed 0000/0001
Figure 7. Sample Error List Printout
Содержание 64
Страница 1: ...CONTINUITY TESTER ASSEMBLY AID MODEL 64 MODEL 64x2 Cablescan ...
Страница 2: ......
Страница 51: ...Model 64 64x2 Instruction Manual Page 43 Figure 8 Schematic Model 64 CPU Board 2 of 3 ...
Страница 52: ...Page 44 Model 64 64x2 Instruction Manual Figure 8 Schematic Model 64 CPU Board 3 of 3 ...