background image

LOOP  CALIBRATOR

INSTRUCTION  MANUAL

C6500 Cabac 4-20mA and 0-10V source.

Содержание C6500

Страница 1: ...LOOP CALIBRATOR INSTRUCTION MANUAL C6500 Cabac 4 20mA and 0 10V source...

Страница 2: ...ions 777 Operating Instruction 888 mA Output Selection AAA Percentage Input BBB Adjusting the Percentage Up and CCC Down Auto Step Function DDD Auto Ramp Function EEE 0 24V Voltage Output FFF Voltage...

Страница 3: ...ter Use the meter only as specified in this manual Otherwise the protection provided by the meter may be impaired Rated enviromental conditions 1 Indoor use 2 Installation Category I 3 Pollution Degre...

Страница 4: ...ACCURACY 0 4V 1mV 0 05 10mV 4 20V 1mV 0 05 5mV 20 24V 1mV 0 05 5mV GENERAL Power Consumption 150mA at 24V 1k load Operating Temperature 0 C 50 C Operating Humidity 80 R H Storage Temperature 10 C 60 C...

Страница 5: ...F Button 7 Numerical Function Keypad 3 Shift Button 8 DC Adaptor Input Socket 4 Voltage Button 9 Stand 5 Current Button 10 Output Terminal 4 20mA LOOP CALIBRATOR 1 2 3 4 20mA 4 7 8 0 9 V I START 5 END...

Страница 6: ...4 Display 666 1 mVA Units 2 0 20mA Output Range of mA 3 Percentage 4 Ramp 5 STEP 6 OL Overload output open 7 SHIFT SHIFT functions 8 low Battery 1 2 3 4 5 6 7 8...

Страница 7: ...range by pressing one of these three buttons Press the SHIFT button then press START 4 button ccc to begin Auto Ramp Function Press the SHIFT button then press the END 5 ddd button to stop Auto Ramp...

Страница 8: ...begin Auto Ramp Function Press again to end Auto Ramp Function Press the SHIFT button then press the button to ggg select the percentage range After the percentage range has been entered use these but...

Страница 9: ...Press ENTER button to accept entry of numbers iii Press the SHIFT button then press V to change to jjj Voltage setting Press the SHIFT button then press the I button to kkk return to mA current setti...

Страница 10: ...4 range Press the SHIFT button and select one of the desired range buttons 1 2 or 3 The selected range will be displayed on the LCD NOTE A maximum of 5 digits can be entered If 5 digits 1 to 4 are ent...

Страница 11: ...ATOR 1 2 3 4 20mA 4 7 8 0 9 V I START 5 END 6 SEC ENTER Shift 0 20mA 0 24mA ON OFF Enter a value less than 1 First select the range 2 or 3 Press the decimal button then enter the desired value followe...

Страница 12: ...based upon 444 the range selected 4 20mA 1 0 16mA start at 4mA 0 20mA 1 0 2mA 0 24mA 1 0 24mA Press SHIFT button to exit out of Percentage Input 555 mode The percentage display at the upper left corn...

Страница 13: ...4 20mA LOOP CALIBRATOR 1 2 3 4 20mA 4 7 8 0 9 V I START 5 END 6 SEC ENTER Shift 0 20mA 0 24mA ON OFF 4 20mA LOOP CALIBRATOR 1 2 3 4 20mA 4 7 8 0 9 V I START 5 END 6 SEC ENTER Shift 0 20mA 0 24mA ON O...

Страница 14: ...exceeds the minimum or maximum percentage the percentage will remain in the previous percentage adjustment Example 1 Adjusting the Percentage Up and Down 25 25 50 75 100 75 50 25 0 25 Example 2 Adjust...

Страница 15: ...4 20mA LOOP CALIBRATOR 1 2 3 4 20mA 4 7 8 0 9 V I START 5 END 6 SEC ENTER Shift 0 20mA 0 24mA ON OFF 4 20mA LOOP CALIBRATOR 1 2 3 4 20mA 4 7 8 0 9 V I START 5 END 6 SEC ENTER Shift 0 20mA 0 24mA ON O...

Страница 16: ...the 9 button Calibrator outputs 0 of the range for 4 seconds Then it will jump to 25 displaying the output for another 4 seconds then 75 for 4 seconds 100 for 4 seconds 75 for 4 seconds 25 for 4 secon...

Страница 17: ...nds Duration 1 Press the SHIFT button and then the SEC 6 button to enter the value in seconds 2 Then press ENTER 75 for x seconds 100 for x seconds 75 for x seconds 25 for x seconds 0 for x seconds 25...

Страница 18: ...owed by buttons 1 2 or 3 for the desired range 2 Prepare the desired START END and DURATION values See instructions for each on page 18 below 3 After setting the START END and DURATION values press th...

Страница 19: ...START 5 END 6 SEC ENTER Shift 0 20mA 0 24mA ON OFF 4 20mA LOOP CALIBRATOR 1 2 3 4 20mA 4 7 8 0 9 V I START 5 END 6 SEC ENTER Shift 0 20mA 0 24mA ON OFF 4 20mA LOOP CALIBRATOR 1 2 3 4 20mA 4 7 8 0 9 V...

Страница 20: ...n End will be displayed at the upper right corner of the LCD 2 Enter the desired value and press the ENTER button DURATION 1 Press the SHIFT button then the SEC 6 button SEC will be displayed at the u...

Страница 21: ...corner of the LCD The mA symbol will disappear from the LCD The values now represent Voltage The default range is 4 20 The 4 20 now represents 4 20V NOTE To return to Current setting press SHIFT then...

Страница 22: ...ng the Battery 1111 When low battery symbol appears on the LCD replace with new batteries 1 Ensure the unit is off by pressing the ON Off button 2 Remove all test lead terminals 3 Remove the two screw...