25
PMC
Adjusts the motor torque applied to the barrier during the closing phase.*
1-99-(20)
PSO
Adjusts the motor torque applied to the barrier during the slowdown in opening phase * (Fig.9 - Slow Open).
1-99-(20)
PSC
Adjusts the motor torque applied to the barrier during the slowdown in closing phase * (Fig.10- Slow Close).
1-99-(20)
SeaU
Not used
SEAR
Not used
tls
Activation time of the courtesy light contact. Value expressed in seconds. At the beginning of
each maneuver the contact latches for the set time.
See the description of AUX1 parameter.
1-240 (60)
saso
Sets a short reversion after reaching the limit switch in open position. Can be useful for facilitat-
ing the manual release.
0-5 (0)
sasc
Sets a short reversion after reaching the limit switch in close position. Can be useful for facilitat-
ing the manual release.
0-5 (0)
aux1
Selects the functioning mode of the auxiliary output 1 (N.O. clean contact)
0: Open barrier light, close contact when the barrier is open, open contact when the barrier is
close, intermittent during the maneuver (fig. 13, SCA)
1: Second radio cannel of the built in receiver
2: Boom light, for controlling the LED light installed on the BOOM (RB400.L), see also the pa-
rameter LBAR.
3: Courtesy light, the contact remains close according to the parameter TLS (fig.13 SERVICE
LIGHT)
4: Photocells test, see wiring diagram in Fig.13 (PHOTOTEST)
5: Close contact with open barrier
6: Close contact with close barrier
0-6-(0)
* ATTENTION: A WRONG SETTING OF THESE PARAMETERS CAN BE DANGEROUS.
RESPECT THE REGULATION IN FORCE!
14.3) LOGICS (
LOG
)
MENU
FUNZIONE
ON-OFF-(Default)
MEMO
TCA
Enables or disables automatic closing
On: automatic closing enabled
Off: automatic closing disabled
(ON)
IbL
Enables or disables condominium function.
On: condominium function enabled. The step-by-step impulse or transmitter impulse has no
effect during the opening phase.
Off: condominium function disabled.
(OFF)
ibca
The multi-flat function is enabled or disabled during the TCA counting.
On: the bloc of flat function is enabled. The Step-by-Step signal or the transmitter signal has no
effect during the TCA counting.
Off: the bloc of flat function is disabled.
(OFF)
SCL
Enables or disables rapid closing
On: rapid closure is enabled. With open bar, or in the opening phase, the activation of the photocell
causes the automatic closure 3sec after the total opening of the gate. It is activated only with TCA:ON
Off: rapid closing disabled.
(OFF)
PP
Selects the operating mode of the ”Step by step button” and of the transmitter.
On: Operation: OPEN > CLOSE > OPEN >
Off: Operation: OPEN > STOP > CLOSE > STOP >
(OFF)
PRE
Enables or disables pre-blinking.
On: Pre-blinking enabled. Blinking is activated 3s before the motor starts.
Off: Pre-blinking disabled.
(OFF)
htr
Enabled or disables HOLD-TO-RUN function
On: HOLD-TO-RUN function.
The pressure of the OPENS/CLOSES button must be maintained throughout the entire manoeuvre.
The opening of the STOP input stops the motor. All the safety inputs are deactivated.
Off: Automatic/semiautomatic function
(OFF)
ltca
Selects the operating mode of the blinking light during the time TCA
On: Blinking light on during TCA
Off: Blinking light off during TCA
(OFF)
TST1
Enables or disables checking of photocells on PHOT input, active both in closing and in opening.
On: Check enabled. If the check has a negative result, no manoeuvre is commanded. See Fig.13
- “PHOTO TEST”.
Off: Checking of photocells disabled at each manoeuvre.
(OFF)
TSTm
Enables or disables motors check.
On: Check enabled. If the check has a negative result, no manoeuvre is commanded.
Off: Check disabled.
(OFF)
Cvar
The code programmable transmitters is enabled or disabled.
On: Radio receiver enabled only for rolling-code transmitters.
Off: Receiver enabled for rolling-code and programmable code transmitters (self-learning and
Dip Switch).
(ON)
Содержание RB.400
Страница 1: ...L854300148 04 2019 rev 1 RB 400 RB 500 IT EN DE FR ES PL www latam us...
Страница 5: ...5 8 G F G F D T 7...