![CAB A2+ Скачать руководство пользователя страница 43](http://html1.mh-extra.com/html/cab/a2/a2_user-configuration-manual_3178962043.webp)
4
4
6
Service Functions
6.7
Cleaning Interval
The
Cleaning interval
function is used for additional printhead maintenance control. The length of medium
which passes the printhead can be selected in increments of 100 m after which the printhead is to be cleaned.
Press the
menu
button.
Select
Service > Cleaning interval
menu.
Press the
button.
Select the desired value with the
|
and
}
buttons or select
Off
to deactivate the
Cleaning interval
function.
Press the
button.
If the set length of the medium (label strip, transfer ribbon) has passed the printhead and an error occurs in the flow
of the medium (e.g. label end, transfer ribbon end), the
Clean printhead!
message appears in the display.
The error message for the error which occurred is not displayed until the
Clean printhead!
message is
acknowledged. As long as no errors occur in the medium flow, no messages are displayed and the print job is
continued even if the cleaning interval has passed.
1.
2.
3.
4.
5.
Содержание A2+