6.7
End Position Dampening
i
Note!
The end position dampening of the lifting cylinder is set to the clients specifications and, under normal
circumstances, do not need to be adjusted.
2
1
Fig. 24
End Position Cushioning
The end position dampening reduces mechanical strain,
especially when the device operates at higher speeds and
with larger masses and thus impact energy.
The dampening should be set up in such a way that both
ends of the cylinders motion are reached securely but with as
little force as possible.
By increasing the end position dampening the lifting speed of
the cylinder is reduced and so the duration for each cycle is
increased.
To increase the end position dampening turn the setting
screw (2) on cylinder (1) clockwise.
To reduce the end position dampening turn the setting
screw (2) on cylinder (1) counterclockwise.
6.8
Adjusting the Options for Movement in Direction Z
Fig. 25
Stopper (Guide Rail)
The stopper (guide rail), with absorption, reduces the speed
of the cylinder Z shortly before impact, as with the end
position dampening, it reduces mechanical strain on the
components.
Make adjustments as described in chapter „6.4 Adjusting the
Sensor on Cylinder Z“
Adjust the stopper with a completely compressed spring.
Fig. 26
Stopper (Pad Assembly)
The stopper hinders the triggering of the labeling sensor due
to the weight of the pad assembly when the installation is
rotated by 90° or 180°.
The adjustment must be done from the start position of the
applicator.
1. Loosen the counter nut of the stopper.
2. Turn the stopper until it lightly touches the pad retainer.
Do not change the take over position of the pad by the
stopper.
3.
Tighten the counter nut to fix the stopper.
3
2
1
MP S
1
2
3
Fig. 27
Pressure reduction valve
Cylinder Z
The pressure reduction valve (2) is used to better label
pressure-sensitive products or to increase the general safety
aspects by reducing the pressure within the cylinder moving
in direction Z.
The standard value is 2.5 bar.
Connect the manometer between the tube and exit (3)
and adjust the pressure to 2.5 bar via knurled screw (1).
It is possible to order an upgraded set with pressure
reduction valve retrospectively or have it installed before
delivery. Installation instruction will be provided with the