Product Description

2.1 

Important Features

• 

The supporting air, the vacuum as well as the speed of the cylinder are adjustable. That way the applicator can be 
adapted to different label materials and sizes.

• 

To avoid contamination within the vacuum channels, tamps are cleaned by an air pressure pulses after each 
application.

• 

For operation within a system the I/O interface of the printer can be used. 

2.2 

Technical Data

Label transfer method

Tamp pad

Tamp pad  
with foam

Tamp pad  

with label stop

Blow pad

4214 L/R 11 F

4214 L/R 12 F

4214 L/R 61 F

4214 L/R 2100

Label width  
in mm for                          

HERMES Q2 / 2

  4 - 58

10 - 58

10 - 58

10 - 58

HERMES Q4 / 4

10 - 80

10 - 80

10 - 80

10 - 80

Label height  
in mm for

HERMES Q2 / 2

  4 - 40

  4 - 40

  4 - 40

10 - 40

HERMES Q4 / 4

  8 - 40

  8 - 40

  8 - 40

10 - 40

Compressed air pressure

0,45 MPa (4,5 bar)

Sound pressure level

unter 74 dB(A)

Product during 
labeling

fixed

¢

¢

¢

¢

in motion

-

-

-

¢

Labeling onto the 
product

from the top

¢

¢

¢

¢

from below

¢

¢

¢

¢

sideways

¢

¢

¢

¢

Product height

fixed

-

-

-

¢

variable

¢

¢

¢

-

 

Horizontal swing angle 90°, 180°, 0°

¢

¢

¢

¢

Product distance to lower edge

at cylinder stroke

200 mm up to mm

135

135

135

140

300 mm up to mm

235

235

235

240

400 mm up to mm

335

335

335

340

Immersion depth pad F

2)

         up to mm

65

65

65

-

Cycle time about frequency/min.

1)

25

25

25

25

Table 1 

Technical Data 

1)  

Determined at 100 mm stroke below device / smallest label height / print speed 100 mm/s.

2)  

Immersion depth at applicator >25 mm, the cover of the HERMES Q /

 must be modified.

Содержание 4214 Series

Страница 1: ...Assembly Instructions 4214 MADE IN GERMANY Stroke Turn Applicator...

Страница 2: ...ucts discrepancies between documentation and product can occur Please check www cab de for the latest update Terms and conditions Deliveries and performances are effected under the General conditions...

Страница 3: ...1 Important Features 6 2 2 Technical Data 6 2 3 Overview 7 2 4 Contents of Delivery 8 3 Mounting 9 4 Operation 10 4 1 Standard Operation 10 4 2 Cleaning 10 4 3 Movement of the Pad 11 5 Error Messages...

Страница 4: ...e The device may only be used for its intended purpose and if it is in perfect working order and it must be used with regard to safety and dangers as stated in the manual The device applicator mounted...

Страница 5: ...e can also endanger operational safety Always have service work done by a qualified workshop where the personnel have the technical knowledge and tools required to do the necessary work There are vari...

Страница 6: ...10 58 HERMES Q4 Hermes 4 10 80 10 80 10 80 10 80 Label height in mm for HERMES Q2 Hermes 2 4 40 4 40 4 40 10 40 HERMES Q4 Hermes 4 8 40 8 40 8 40 10 40 Compressed air pressure 0 45 MPa 4 5 bar Sound p...

Страница 7: ...view 1 Cover 2 Compressed air connector 3 Shutoff valve 4 Pad customized 5 Blow tube for supporting air 6 Knurled screw for attaching the applicator to the printer 7 Hinges 8 SUB D 15 Connector elec c...

Страница 8: ...ws part of the pad 5 Documentation Fig 3 Contents of delivery i Note Please keep the original packaging in case the applicator must be returned Attention The device and printing materials will be dama...

Страница 9: ...en the thumbscrew 5 5 Keep the external compressed air supply closed and close the shut off valve 10 on the applicator see illustration 6 Insert external compressed air supply 8 into the plug connecto...

Страница 10: ...ually After a few seconds the printer carries out a short backfeed to position the front edge of the next label at the printing line i Note This synchronization also has to be carried out when the pri...

Страница 11: ...inder X X X X 4 Pad moved to the inclined position below the dispensing plate of the printer and stops X X 5 Pad will swing in via a rotation cylinder X X 6 Pad moves in the swing in position to the p...

Страница 12: ...XSTP signal Upper position not left Refl sensor blk Hermes There has been no change of the switch state at the upper sensor at the cylinder between the start of the labelling process and the signal f...

Страница 13: ...e Stroke Turn Applicator Type 4214 Applied EU Regulations and Norms Directive 2006 42 EC on machinery EN ISO 12100 2010 EN ISO 13849 1 2015 EN 60950 1 2006 A11 2009 A12 2011 A1 2010 A2 2013 Person aut...

Страница 14: ...d below this statement shall thereby be made invalid Device Stroke Turn Applicator Type 4214 Applied EU Regulations and Norms Applied Norms Directive 2014 30 EU relating to electromagnetic compatibili...

Отзывы: