Error Messages

5.1 

Error Messages of the Printer

For detailed information about printer errors (e.g. 'Paper out', 'Ribbon out', etc.) 

 Check the operator's manual of the 

printer.

Error treatment:

 

Clearing the error results.

 

Press the 

 

respectively

 feed

 to synchronize the label feed, remove the left over labels manually.

To quit the error state press 

Repeat 

 (HERMES Q) respectively the 

pause

 key (

)

.

After error correction, the label causing the error will be reprinted.

5.2 

Error messages of the applicator

The following table contains an overview of error messages and their possible causes. It also suggests methods to 
resolve the problem :

Error Message

Possible Cause

Air pressure error
Air pressure ins. 

()

Compressed air is switched off

Pressure to low < 4 bar

Pressure to high > 6 bar

Label not depos.

Label has not been placed onto the product; after the pad has moved back the label still 
sticks on the pad

Upper position not reached
Upper position 

()

Pad is not in start position if the printer swiched on

Pad has not reached the labelling position within 2s after the movement of the pad was 
started

Pad has undefined leaving the start position

External error 
Process Error 

()

Process of labeling was braked via the I/O interface of the printer with the  XSTP signal

Upper position not left

Refl. sensor blk. 

()

There has been no change of the switch state at the upper sensor at the cylinder 
between the start of the labelling process and the signal from the labelling position 
sensor

Vac. plate empty

Label has not been picked up properly by the pad; or label fell off the pad before it could 
be placed onto the product

Lower position not reached
Lower position 

()

Pad has not reached the starting position within 2s after the pad has left the labelling 
position; or pad has left  the starting position unauthorized

Table 3 

Error messages of the applicator

Error treatment:

 

Clear the error state.

 

In order to clear the error state press 

continue, repeat 

or

 cancel.

 

Continue

  

with the next label in the printing queue. 

Repeat

  

respectively the 

pause

 and enter   key repeat the print of the label causing the error.  

 

 

Only applicable with error 

Vac. plate empty.

 

Cancel

  

the current print job.

!

Warning!

After the error has been resolved the pad will immediately move back to the starting position!

Danger of injury to hands and fingers by the moving pad! 

 

Do not reach into the area of the moving pad and keep long hair, loose clothes, and jewelry away.

Reprinting a label, interrupted by an error, is not possible without a new printing job. 

 

In the mode "apply/print" before the standard cyclic operation can commence the signal "print first label" must be 

sent or push 

 respectively the enter   key to send a printed label to the pad.

Содержание 4214 Series

Страница 1: ...Assembly Instructions 4214 MADE IN GERMANY Stroke Turn Applicator...

Страница 2: ...ucts discrepancies between documentation and product can occur Please check www cab de for the latest update Terms and conditions Deliveries and performances are effected under the General conditions...

Страница 3: ...1 Important Features 6 2 2 Technical Data 6 2 3 Overview 7 2 4 Contents of Delivery 8 3 Mounting 9 4 Operation 10 4 1 Standard Operation 10 4 2 Cleaning 10 4 3 Movement of the Pad 11 5 Error Messages...

Страница 4: ...e The device may only be used for its intended purpose and if it is in perfect working order and it must be used with regard to safety and dangers as stated in the manual The device applicator mounted...

Страница 5: ...e can also endanger operational safety Always have service work done by a qualified workshop where the personnel have the technical knowledge and tools required to do the necessary work There are vari...

Страница 6: ...10 58 HERMES Q4 Hermes 4 10 80 10 80 10 80 10 80 Label height in mm for HERMES Q2 Hermes 2 4 40 4 40 4 40 10 40 HERMES Q4 Hermes 4 8 40 8 40 8 40 10 40 Compressed air pressure 0 45 MPa 4 5 bar Sound p...

Страница 7: ...view 1 Cover 2 Compressed air connector 3 Shutoff valve 4 Pad customized 5 Blow tube for supporting air 6 Knurled screw for attaching the applicator to the printer 7 Hinges 8 SUB D 15 Connector elec c...

Страница 8: ...ws part of the pad 5 Documentation Fig 3 Contents of delivery i Note Please keep the original packaging in case the applicator must be returned Attention The device and printing materials will be dama...

Страница 9: ...en the thumbscrew 5 5 Keep the external compressed air supply closed and close the shut off valve 10 on the applicator see illustration 6 Insert external compressed air supply 8 into the plug connecto...

Страница 10: ...ually After a few seconds the printer carries out a short backfeed to position the front edge of the next label at the printing line i Note This synchronization also has to be carried out when the pri...

Страница 11: ...inder X X X X 4 Pad moved to the inclined position below the dispensing plate of the printer and stops X X 5 Pad will swing in via a rotation cylinder X X 6 Pad moves in the swing in position to the p...

Страница 12: ...XSTP signal Upper position not left Refl sensor blk Hermes There has been no change of the switch state at the upper sensor at the cylinder between the start of the labelling process and the signal f...

Страница 13: ...e Stroke Turn Applicator Type 4214 Applied EU Regulations and Norms Directive 2006 42 EC on machinery EN ISO 12100 2010 EN ISO 13849 1 2015 EN 60950 1 2006 A11 2009 A12 2011 A1 2010 A2 2013 Person aut...

Страница 14: ...d below this statement shall thereby be made invalid Device Stroke Turn Applicator Type 4214 Applied EU Regulations and Norms Applied Norms Directive 2014 30 EU relating to electromagnetic compatibili...

Отзывы: