Operation

4.1 

Standard Operation

 

Check all external connections.

 

Load the material. Ensure that the locking system is locked 

 "Operator's Manual" of the printer.

 

Open the shutoff valve.

!

Attention!

 

Ensure that the pad is not covered by a label when switching on the printer-applicator system. 
Otherwise the vacuum sensor may be calibrated incorrectly.

 

 Switch on the printer. 

i

Note!

If the pad is outside the starting position when the printer-applicator system is switched on the procedure 
will be interrupted with an error message visible on the display.

Pushing the pause button on the printer will negate the error moving the pad to the starting position. 
The Applicator is ready for work.

 

Press the 

 

respectively

 feed

 at the printer. 

A synchronization feed is initiated. The processed labels have to be removed manually. After a few seconds the 
printer carries out a short backfeed to position the front edge of the next label at the printing line. 

i

Note!

This synchronization also has to be carried out when the print job has been interrupted with the cancel key.

Synchronizing is not necessary when the print head was not lifted between print jobs. This also applies if 
the printer was powered down between print jobs.

 

Start a print job.

 

Start the labelling process via PLC interface.

Error messages during labelling process are shown in the display of the printer 

 4  Error Messages.

4.2 

Cleaning

!

Attention!

Never use solvent and abrasive.

1

 

Clean the outside surfaces with multi purpose cleaner.

 

During regular use dust particles as well as label snippets 
may accumulate. Remove these with a soft brush and/or a 
vacuum cleaner.

 

Especially at the slide foil (1) debris may gather. To ensure 
an ideal takeover and handling of the label it is necessary 
to clean the surface of slide foil at regular intervals.

Fig. 5 

 Cleaning pad with slide foil

Содержание 4214 Series

Страница 1: ...Assembly Instructions 4214 MADE IN GERMANY Stroke Turn Applicator...

Страница 2: ...ucts discrepancies between documentation and product can occur Please check www cab de for the latest update Terms and conditions Deliveries and performances are effected under the General conditions...

Страница 3: ...1 Important Features 6 2 2 Technical Data 6 2 3 Overview 7 2 4 Contents of Delivery 8 3 Mounting 9 4 Operation 10 4 1 Standard Operation 10 4 2 Cleaning 10 4 3 Movement of the Pad 11 5 Error Messages...

Страница 4: ...e The device may only be used for its intended purpose and if it is in perfect working order and it must be used with regard to safety and dangers as stated in the manual The device applicator mounted...

Страница 5: ...e can also endanger operational safety Always have service work done by a qualified workshop where the personnel have the technical knowledge and tools required to do the necessary work There are vari...

Страница 6: ...10 58 HERMES Q4 Hermes 4 10 80 10 80 10 80 10 80 Label height in mm for HERMES Q2 Hermes 2 4 40 4 40 4 40 10 40 HERMES Q4 Hermes 4 8 40 8 40 8 40 10 40 Compressed air pressure 0 45 MPa 4 5 bar Sound p...

Страница 7: ...view 1 Cover 2 Compressed air connector 3 Shutoff valve 4 Pad customized 5 Blow tube for supporting air 6 Knurled screw for attaching the applicator to the printer 7 Hinges 8 SUB D 15 Connector elec c...

Страница 8: ...ws part of the pad 5 Documentation Fig 3 Contents of delivery i Note Please keep the original packaging in case the applicator must be returned Attention The device and printing materials will be dama...

Страница 9: ...en the thumbscrew 5 5 Keep the external compressed air supply closed and close the shut off valve 10 on the applicator see illustration 6 Insert external compressed air supply 8 into the plug connecto...

Страница 10: ...ually After a few seconds the printer carries out a short backfeed to position the front edge of the next label at the printing line i Note This synchronization also has to be carried out when the pri...

Страница 11: ...inder X X X X 4 Pad moved to the inclined position below the dispensing plate of the printer and stops X X 5 Pad will swing in via a rotation cylinder X X 6 Pad moves in the swing in position to the p...

Страница 12: ...XSTP signal Upper position not left Refl sensor blk Hermes There has been no change of the switch state at the upper sensor at the cylinder between the start of the labelling process and the signal f...

Страница 13: ...e Stroke Turn Applicator Type 4214 Applied EU Regulations and Norms Directive 2006 42 EC on machinery EN ISO 12100 2010 EN ISO 13849 1 2015 EN 60950 1 2006 A11 2009 A12 2011 A1 2010 A2 2013 Person aut...

Страница 14: ...d below this statement shall thereby be made invalid Device Stroke Turn Applicator Type 4214 Applied EU Regulations and Norms Applied Norms Directive 2014 30 EU relating to electromagnetic compatibili...

Отзывы: