Applicator - PLC Interface
A-6
cab - Produkttechnik GmbH & Co KG
PIN13 - XETF
- Applicator fault
This is an error message of the applicator.
This message is shown when one of the following errors occurs at the
applicator :
- pad has not reached the labelling position within 2s after the
movement of the cylinder
- pad has not reached the starting position within 2s after the
movement of the cylinder
- a printed label has not been picked up by the pad properly or it fell
down during the movement of the cylinder (message of the vacuum
sensor)
- the label is still on the vacuum plate of the pad when the cylinder
moves back up (message of the vacuum sensor)
The type of fault is shown in the display of the printer.
In this state the contact between PIN13 and PIN14 is opened.
After fault correction, the print of the last label printed before the fault
occured will not be repeated.
PIN14 - RÜL
- Reverse line (for all output signals)
PIN15 - 24P
- Operating v24V, Si T 100mA
There is an operating voltage of 24V available on PIN15 provided from
the applicator system.
CAUTION !
You must not apply any external voltage on PIN15 !
The operating voltage on the plug connector allows the use of the
applicator without being part of a networked system. The start signal
which is required for releasing the labelling process may be caused,
for instance, by a suitable foot controlled switch with a 15 pin SUB-D
plug.