- 15 -
value. Range:±2.0T.
Note:All parameters will change with type settings. Please do not change type set freely.
Default setting : Press this button, all parameter will reset to default setting. The default setting
is not your need always, so do not press this button freely.
System menu : It is used for setting display time of bright screen.
Home : Pressing this button will be back to homepage.
Indictor light meanings on top right corner:
PWR : Power indictor (Red);It is normally bright.
COM : Communication light(Green);It is quickly flashing.
RUN : PLC running (Indictor Green); It is slowly flashing.
V. Maintenance Instruction
In order to guarantee normal operating of the oil pump,please make the equipment work in
room temperature range 10
℃
to 40
℃
.
Our oil tank adopts leak-proof structure to make sure the cleaning of hydraulic oil in oil tank
and avoid polluted hydraulic oil flowing into oil tank.
Under normal circumstances, please check the oil level every 3 months. If leak, find out the
reason, solve with it and check the oil level at once. Supply with the same type of hydraulic oil
to make the oil level is not lower than the middle of oil level indicator.
Change the hydraulic oil in oil tank every 2000 work hours. Before oil change, clean the oil
tank first.
Fill oil in filler hole on the side of swinging arm every 200 work hours. Please use oil gun to fill
with lithium base grease.
Clean the inner and outer wall of the press mould and the compression face at once after use.
Tear down and clean the mould regular, especially to boric acid mould, aluminum cup mould