C-TEC XFP501/CA Скачать руководство пользователя страница 19

USER MANUAL & LOG BOOK • Approved Document No. DFU5020000 Rev 3 • Page 19 of 24

CAST XFP 16 & 32 ZONE ANALOGUE ADDRESSABLE FIRE ALARM PANEL

Fig.3 : CAST XFP Access Level 1 and 2 Menu structure

ENTER ACCESS LEVEL 3
DISPLAY FIRE EVENTS *
DISPLAY FAULT EVENTS *
DISPLAY DISABLEMENTS *
DISPLAY ZONES IN TEST *
LAMP TEST
DISPLAY ALARM COUNTER
SET TIME/DATE
EVENT LOG FUNCTIONS
SET/CLEAR DISABLEMENTS
CHANGE ACCESS LEVEL 2 CODE

AL2

AL2 K/S

ENTRY

PRINT EVENT HISTORY
DISPLAY EVENT HISTORY
RESET EVENT HISTORY

AL2 CODE

ENTRY

ENTER ACCESS LEVEL 2
ENTER ACCESS LEVEL 3
DISPLAY FIRE EVENTS *
DISPLAY FAULT EVENTS *
DISPLAY DISABLEMENTS *
DISPLAY ZONES IN TEST *
LAMP TEST
DISPLAY ALARM COUNTER

KEYSWITCH (K/S)

(model dependent)

AL1 - ACCESS LEVEL 1

AL2 - ACCESS LEVEL 2 (Code 3333)

* THE MENU OPTION SHOWN WILL ONLY BE 

AVAILABLE IF RELEVANT TO THE PANEL’S STATUS.

ENABLE/DISABLE ZONES
ENABLE/DISABLE SOUNDERS
ENABLE/DISABLE OUTPUTS
ENABLE/DISABLE RELAYS
ENABLE/DISABLE DEVICES
ENABLE/DISABLE FAULT RELAY
ENABLE/DISABLE OUTPUT DELAYS

Total Alarms = nnn
Alarms Since  nn/nn/nn = n

AL1

Menu button

(model dependent)

MENU NAVIGATION

PRESS ACCEPT       BUTTON TO MOVE FORWARD.

PRESS ESCAPE       BUTTON TO MOVE BACK.

PRESS SCROLL       BUTTON TO MOVE UP.

PRESS SCROLL       BUTTON TO MOVE DOWN.

Total Alarms = nnn
Alarms Since nn/nn/nn = nn

Clear to todays date?
Alarms Since nn/nn/nn = nn

Changing the access level 2 entry code

This function allows you to change the four digit code needed to enter the panel’s access level 2 menu 
options.

AL2 (3333) > Change Access Level 2 Code

When selected, press the Accept

4

 

button and the following window will appear:

Using the 

5

(1), 

4

(2), 

6

(3), 

3

(4) buttons, enter the new four digit access level 2 entry code. After 

the fourth digit has been entered, the panel will request you confirm the new code by re-entering it.

Enter the code again by pressing the 

5

(1), 

4

(2), 

6

(3), 

3

(4) buttons in same sequence. If the two 

codes match, the panel will accept the code and you will be taken back to access level 2. If you type an 
incorrect confirmation code you will be prompted to start the new code entry sequence again.

BE SURE TO KEEP A RECORD OF THE NEW CODE ON PAGE 20 OF THIS USER MANUAL.

Enter NEW Access Level 2 Code

Enter NEW Access Level 2 Code: ****
Confirm NEW Access Level 2 Code:

Содержание XFP501/CA

Страница 1: ...nalogue Addressable Fire Alarm Control Panel 1 Loop 16 Zone Panel Part No XFP501E CA 1 Loop 32 Zone Panel Part No XFP501 CA 2 Loop 32 Zone Panel Part No XFP502 CA User Manual Log Book Approved Documen...

Страница 2: ...onditions 11 Access level 1 general user controls and menu options 12 13 Displaying fire fault disablement and test events 12 13 Testing the panel s lamps 13 Displaying the panel s alarm counter 13 Ac...

Страница 3: ...e Installation and Programming Manual for this product and have the necessary skills for maintaining the equipment If the panel is damaged in any way expert advice should be sought regarding its repai...

Страница 4: ...e or reset a fire condition to resound the alarm sounders to disable or enable parts of the system to suit prevailing conditions to change the panel s date and time and to test the panel s indicators...

Страница 5: ...faults or false alarms 47h 8 Ensure that any structural or occupancy changes planned for the building are done so with due and early consideration given to any changes that may be required to the fir...

Страница 6: ...em fault delays running supply present more information escape accept EN54 2 EN54 4 XFP The system must be tested regularly If in doubt refer to the user manual CA ST XFP SERIES 176b 10 59 03 24 Jun N...

Страница 7: ...a sounder disablement anywhere on the system Delays Running Lit yellow when one or more output delays have been programmed by an engineer Flashes yellow when one or more output delays are running Butt...

Страница 8: ...uts delayed is displayed if one or more delays to outputs have been programmed by an engineer It indicates that certain outputs which may include sounders relays and or output units will not trigger i...

Страница 9: ...o fire but all previous zones will now appear on a step by step basis with details of which order they went into fire i e 1st zone 2nd zone etc Pressing the More Information button at any time will gi...

Страница 10: ...t up with an investigation delay period Press the More Information button to display the actual device that has triggered the 1st stage fire condition pressing More Information again will count down h...

Страница 11: ...pertinent to that fault will be displayed instead if available For device specific faults pressing the More Information button again will display the unique ID code and address location of the faulty...

Страница 12: ...changes should appear on the System Set Up Data Chart on page 20 of this user manual If they do not contact your maintenance company As soon as the code has been entered correctly you will be taken in...

Страница 13: ...utton once A window similar to the one below will appear Pressing the 5 and 6 buttons will scroll the display through all zones in test mode To return to the main access level 1 menu press the Escape3...

Страница 14: ...I Silencing the alarm sounders To silence any active alarm sounders enter access level 2 see above and press the Silence Resound Sounders button The alarm sounders will cease to sound and the panel s...

Страница 15: ...LIFE AND VOID ITS WARRANTY If you are an engineer details of access level 3 can be found in the panel s separate engineering manual Testing the panel s lamps AL2 3333 Lamp Test This function tests th...

Страница 16: ...and scroll down to the desired function using the 6 button Note The PRINT EVENT HISTORY function is for future AL2 3333 Event Log Functions Display Event History The DISPLAY EVENT HISTORY menu option...

Страница 17: ...cannot be done Instead you must first enable at least one device on the zone using the ENABLE DISABLE DEVICES function before re enabling the zone itself AL2 3333 Set Clear Disablements Enable Disable...

Страница 18: ...flash Next use the 5 and 6 buttons to toggle between enabled and disabled and press the Accept4 button to select the desired option The window will now move to the next device allowing further enablem...

Страница 19: ...nn Alarms Since nn nn nn n AL1 Menu button model dependent MENU NAVIGATION PRESS ACCEPT BUTTON TO MOVE FORWARD PRESS ESCAPE BUTTON TO MOVE BACK PRESS SCROLL BUTTON TO MOVE UP PRESS SCROLL BUTTON TO MO...

Страница 20: ...for access level 2 using the pushbuttons on the panel is 3 3 3 3 four presses of the 6 key If this code is changed make a note of the changes here New access level 2 code Date changed ________________...

Страница 21: ...tests including fire drills Dates and times of all fires to which the system responds Dates and times of all false alarms Causes circumstances surrounding and category of false alarms if known The id...

Страница 22: ...IRE ALARM PANEL Details of tests including fire drills actual fire alarms disablements enablements and faults should be recorded here Note BEFORE ENTERING DETAILS ON THIS FORM PHOTOCOPY ADDITIONAL SHE...

Страница 23: ...ESSABLE FIRE ALARM PANEL PHOTOCOPY ADDITIONAL SHEETS AS REQUIRED DATE TIME EVENT e g test fire alarm signal fault ZONE DEVICE ACTION REQUIRED COMPLETED INITIALS USER MANUAL LOG BOOK Approved Document...

Страница 24: ...NDINGS OF MAINTENANCE TECHNICIAN CATEGORY OF FALSE ALARM FURTHER ACTION REQUIRED DONE PLEASE TICK DATE TIME ZONE WHERE APPLICABLE DEVICE WHERE APPLICABLE REASONS FOR WORK WORK CARRIED OUT FURTHER WORK...

Отзывы: