CXL2/DXL2/MXL2 Locators:
Technical Specifications
Controls:
- On/Off Switch, spring loaded trigger switch under handle.
- Function Select Switch:
- 4 position:
P – Power Mode
R – Radio Mode
G - Generator Mode
(
or T – Transmitter Mode
MXL2
only
)
A –
All Scan Mode
- Sensitivity Control.
- Depth Button.
DXL2 MXL2
only
Pushbutton for live display of depth.
- Current Measurement Button.
MXL2
only
Pushbutton for live display of Transmitter current.
- Frequency Select Button.
MXL2
only
Pushbutton for Transmitter Mode frequency selection.
Indications:
Audio
- Removable and user replaceable loudspeaker module.
Visual:
Multi-segment Liquid Crystal Display with automatic backlight
gives indications of the following:
- Signal Strength
- Mode
- Battery Condition
- Self Test Indicator
When in Generator/ Transmitter Mode the following is also displayed:
- Frequency
- Depth (when selected)
DXL2 MXL2
only
- Signal Current (when selected)
MXL2
only
Data Logging:
Internal capacity for 12 months of data logged once per second.
Data logged includes Time/Date, Mode, Sensitivity Level, Received Signal Level,
Frequency, Depth, Self Test Result, Swing Indicator.
Data Connector:
Standard USB Mini B connector in battery compartment. USB 2.0 Compatible.
Self Test:
Built in Self Test cicuitry automatically triggered to run on first use of the day.
Swing Indicator:
Audio beep to indicate incorrect use of the Locator.
Generator Mode/ Transmitter Mode Frequencies:
Simultaneous 131,072Hz and 32,768Hz
Simultaneous 131,072Hz and 32,768Hz; 8,192Hz; and 640/512Hz
MXL2
only
Performance:
Locate Accuracy:
better than ±5% of depth.
Depth Accuracy:
better than ±5% @ 10mA
DXL2 MXL2
only
Depth Measurement Range:
Line 0.2m to 3m
Sonde 0.25m to 9.9m (depending on Sonde type)
Current Measurement:
0.01mA to 100mA
MXL2
only
Construction:
- Case moulded from high impact plastic, sealed to IP65.
- Weight: 2.65kg (including batteries)
- Size: 720mm x 280mm x 65mm
- Designed to withstand 1m drop onto a hard surface.
Power Source:
- Internal 8 x ‘AA’ (LR6) cells (either alkaline non-rechargeable
or NiMH rechargeable)
- Battery Life: 40 hours intermittent use at 20ºC using alkaline cells.
Note:
Performance figures stated can be affected by site parameters such as ground
conditions, temperature, and strong electromagnetic fields.
All C.Scope Locators are in compliance with the essential requirements
and other relevant provisions of Council Directive 89/336/EEC. Compliance
has been demonstrated by testing representative samples to the relevant
harmonised standards.
All C.Scope Locators comply with the RoHS directive, 2002/95/EC.
57