7
11.2 Door settings
Relay output delay time
To set door relay strike time
.
*
. .
Master code
. .
#
. .
4
. .
0 – 99
. .
#
. .
*
.
0 – 99 is to set the door relay time to 0 – 99 seconds
Door open detection
Door open too long (DOTL) warning. When used with an optional magnetic contact or a magnetic lock with a built-in contact,
if the door is opened normally, but not closed after one minute, the inside buzzer will beep automatically to remind people to
close the door and continue for one minute before switching off automatically.
Door forced open warning. When used with an optional magnetic contact or a magnetic lock with a built-in contact, if the
door is forced open, or if the door is opened after 20 seconds, the inside buzzer and alarm output will both operate. The
alarm output time is adjustable between 0 – 3 minutes, with the default being 1 minute.
To disable door open detection (factory
default)
.
6
. .
0
. .
#
.
To enable door open detection
.
6
. .
1
. .
#
.
To change a
PIN
in card and PIN mode
(method 1)
Change using card. Note that this is done
outside of programming mode so the user can
undertake this themselves.
.
*
. .
Read card
. .
Old PIN
. .
#
. .
New PIN
. .
#
. .
New PIN
. .
#
.
To change a
PIN
in card and PIN mode
(method 2)
Change using User ID number. Note that this is
done outside of programming mode so the user
can undertake this themselves.
.
*
. .
ID number
. .
#
. .
Old PIN
. .
#
. .
New PIN
. .
#
. .
New PIN
. .
#
.
To delete
card and PIN
user
To delete the user just delete the card
.
2
. .
User ID number
. .
#
.
To add a card user in card mode (
.
3
.
.
0
.
.
#
.
) mode.
To add or delete a
card
user
The operating is the same as adding and deleting a card user in
.
3
.
.
0
.
.
#
.
To delete all users
To delete all
users
Please note this is a dangerous operation, use
with care
.
2
. .
0000
. .
#
.
To unlock the door
For a
PIN
user
Enter the
.
PIN
.
then press
.
#
.
For a
card
user
.
Read card
.
For a
card and PIN
user
.
Read card
.
then enter
.
PIN
. .
#
.