8.

 

To reset to factory default 

 

a.

 

Disconnect power from the unit. 

b.

 

Press and hold the # key whilst powering the unit back up. 

c.

 

On hearing the two “Di” sounds, release the # key, system is now back to factory settings. 

Please note only installer data is restored, user data will not be affected. 

 

9.

 

Anti- tamper alarm 

The unit uses an LDR (light dependent resistor) as an anti-tamper alarm. If the keypad is removed from the 
cover then the alarm will operate. 

 

10.

 

  Sound and light indication 

Operation Status 

Red Light 

Green Light 

Yellow Light 

Buzzer 

Power on 

Bright 

Di 

Stand by 

Flashing 

Press keypad 

Di 

Operation successful 

Bright 

Di 

Operation failed 

DiDiDi 

Enter into programming mode 

Solid 

In the programming mode 

Solid 

Di 

Exit from the programming 

Bright 

Di 

Open the door 

Solid 

Di 

Alarm 

Flashing 

Alarm 

 

11.

 

  Detailed programming guide 

11.1  User settings 

To enter programming mode 

 

.

*

.

   Master code   

.

#

.

 

 

 

999999 is the default master code

 

To exit programming mode 

 

.

*

.

 

Note that to undertake the following programming the master user must be logged in

 

To change the master code 

 

.

0

.  .

New code

.

 

 .

#

.  .

New code

.

 

 .

#

   

 

The master code can be 6 to 8 digits

 

 

Setting the working mode: 

 

Set valid card users only 

 

Set valid card 

and

 PIN users 

 

Set valid card 

or

 PIN users 

 

 

 

 

.

3

.

  

.

0

.

  

.

#

.

  

Entry is by card only 

 

.

3

.

  

.

1

.

  

.

#

.

  

Entry is by card 

and

 PIN together

 

 

.

3

.

  

.

2

.

  

.

#

.

  

Entry is by either card 

or

 PIN (default) 

 

Содержание DPS

Страница 1: ...c Quantek 59 Sheffield Road Dronfield S18 2GF 44 0 1246 417113 sales cproxltd com www quantek co uk Standalone Keypad Access Control DPS DPS W User Manual Please read the manual carefully before insta...

Страница 2: ...delete a PIN or card user 2 User ID number for a PIN user or 2 Read card for a card user Users can be deleted continuously without exiting programming mode To unlock the door for a PIN user Enter the...

Страница 3: ...perating voltage 12 24Vdc User capacity 2000 Card reading distance 3 6 cm Active current 60 mA Idle current 25 5 mA Lock output load Max 3A Alarm output load Max 20A Operating temperature 45 to 60 C O...

Страница 4: ...alarm positive connected to 12 24V Yellow OPEN Exit button one end the other end connected to GND Brown D_IN Magnetic switch one end the other end connected to GND Red 12 24V 12 24V DC regulated power...

Страница 5: ...by Flashing Press keypad Di Operation successful Bright Di Operation failed DiDiDi Enter into programming mode Solid In the programming mode Solid Di Exit from the programming Bright Di Open the door...

Страница 6: ...s the last 8 digits printed on the back of the card User ID number auto generation 1 Card number Users can be added continuously without exiting programming mode To add a card user method 4 In this me...

Страница 7: ...tes with the default being 1 minute To disable door open detection factory default 6 0 To enable door open detection 6 1 To change a PIN in card and PIN mode method 1 Change using card Note that this...

Страница 8: ...re are 10 invalid cards or 10 incorrect PIN s entered in a 10 minute period either the keypad will lockout for 10 minutes or both the alarm and inside buzzer will operate for 10 minutes depending on t...

Страница 9: ...9 Issue record Site Door location User ID No User name PIN Card number Issue date 0001...

Отзывы: