4 | C-ITRONE 200/300

 

 

2 TRANSPORT AND INSTALLATION

 

 

 

2.1 General Unit Check 

 

 
 
 
 
 
 
 

 

 

2.2 Technical Data 

 

2.3 Transport / Storage

 

The unit should only be stored at a temper-ature 
range from -25°C (-13°F) to +55°C (+131°F)  

 

 

 

 

 

Damage to the unit can be caused by incor-rect 
transport, set-up, or deconstruction. 

Unit should always be set and secured on level, 
solid ground. The unit must always be operated 
in  closed  rooms,  in  a  safe  and  controlled 
environment. 

 

2.4 Set-up/Start-up

 

 
 
 

 

Damage  to  the  unit  can  be  caused  by  in-correct 
transport, set-up, or deconstruc-tion. 

2.5 Electrical Plug/ Electrical Fuses

 

 

 
 
 
 
 
 
 

The electrical fuses for this unit are locat-ed directly below 
the 3-prong power plug on the unit casing. Be aware that 
re-placement of worn out fuses may be nec-essary. In this 
case, only use 2A replace-ment fuses, which can be found 
at almost any local electrical parts store. One (1) 2A equals 
one (1) fuse. 

2.6 Suction Hose Attachment

 

 

 

The suction hose is attached to the unit through an easy 
''click-system''. Simply push the front ring back, attach the 
suction  hose  to  the  unit,  and  pull  the  front  ring  for-ward 
again, insuring that the hose is sitting tight in the correct 
position.. 

 

 

Unit

 

Has been placed 
securely and on solid 
ground

 

 

Electrical plug

 

Is free of damages

 

 

Vacuum hose and 
suction cup

 

Is free of damages

 

 

Pressure 
Regulator

 

Function check

 

 

 

Unit Type

 

C 200

 

C 300

 

Measurement 
(l x w x h)

 

40 x 50 x 26 cm

 

40 x 50 x 26 cm

 

Weight

 

10 kg (22lbs)

 

10 kg (22lbs)

 

Energy  
Voltage 
Frequency

 

2 A

 

230 Volt

 

50 Hz

 

2 A

 

230 Volt

 

50 Hz

 

Rated Currency

 

2 A

 

2 A

 

Rated Capacity

 

460 W

 

460 W

 

 

Содержание C 200

Страница 1: ...or Button must be in the out position in order to regulate suction Dauer Vakuumregulierung 10Filterpatrone und Geh use 10 Filter Cartridge Filter Cartridge Housing 11 Utility Case Lid with built in Ke...

Страница 2: ...4 Set up Start up 4 2 5 Electrical Plug Electrical Fuses 4 2 6 Suction Hose Attachment 4 3 OPERATING YOUR C200 300 3 1 Turning On Unit 5 3 2 Operation 5 3 8 Maintenance 5 4 TROUBLESHOOTING MAINTENANC...

Страница 3: ...hazards caused by operating the unit 1 3 Intended Use nurf rPferdeundHunde For equine and canine only To be used only inside rooms with dry conditions To be used only in temperatures rang ing from 5 C...

Страница 4: ...e unit casing Be aware that re placement of worn out fuses may be nec essary In this case only use 2A replace ment fuses which can be found at almost any local electrical parts store One 1 2A equals o...

Страница 5: ...number of full cycles se lected by user the lightbulb symbol shows an infinite number of time cycles From left to right FI LS button releases in the event of a short circuit Release button T releases...

Страница 6: ...h the paper filter causing the paper to become moist A moist paper filter will re sult in the inability for the suction pump to build suction Should the paperfilterneed to be replaced make sure to use...

Страница 7: ...th the perfect amount of suction The result is a wide range of benefits increased blood flow circulation of the tissue stimulation of the lymph flow and strengthening of the immune system as well as r...

Страница 8: ...8 C ITRONE200 300 7 FINDING THE NEURAL POINTS ON A HORSE 7 1 Illustration In top regions use glasses H1 H2 H3 In lower regions use glasses H4 H5 H6...

Страница 9: ...ded to support the horse sbodytissue Thisspeedsupthebody sability to transport nutrients to damaged body tissue while ridding itself of harmful metabolic toxins Moreover newly developed fibers are exp...

Страница 10: ...a on injuries acute infection on foals or on old and or weak horses no induced bleeding RESIDUAL RISKS Using the equine cupping machine foranything other than its intended use can result in the follow...

Страница 11: ...d diameter and the strongest of all suction levels Compatible with H1 USE OF H4 The H4 glass cup is the smallest of suction cups The two knobs one placed on each side of the cup make for easy handling...

Отзывы: