Duration
Length of time of Manual Movement using increments of 50ms
i.e. duration time of movement - 1 x 50ms = 50ms
Speed
Motor Speed of Manual Movement
1 = Slowest, 9 = Highest
Fig. 64:
Duration and Speed Input for Manual Movements
DVB Signal (0-255)
DVB Signal received from the DVB Tuner. A “U” next to the
value indicates an “unlocked” status. An “L” next to the DVB
value indicates locked signal.
Beacon Signal (0-100)
If the optional beacon receiver is used, the Beacon Signal will
appear in this area along with the power density received
from the satellite. This will only appear when a lock status
occurs which is indicated by an “L” next to the beacon signal
value.
RF Signal (30-120)
Displays the real time RF Signal throughout the acquisition
process. A value of 30 that is flashing Red and or Yellow
indicates the LNB is not being powered appropriately, or
there is an issue with the coax cable connection.
RF Threshold (30-75)
Used in RF mode search for determining proper satellite frequency. This can be configured and
viewed on the Configuration screen.
Antenna Latitude/Longitude
GPS Coordinates acquired from the GPS Antenna or manually overridden values.
Remote Voltage (V)
Voltage (DC) reading on the 7720 Remote Controller
Remote
Current(mA) of 7720 Controller
Displays Current drawn for Elevation and Azimuth Motor