5 – Motion Protection
iNetVu
®
Platform will automatically stow if the antenna detects extreme motion, such as severe
shaking caused by poor weather conditions. If the shaking/shift is in small increments the system
will not stow assuming signal is not lost. If the small motion/movement count (12 small
movements in 30 seconds) logged in a specific time window exceeds the set threshold the
system will re-peak if signal exists or stow if signal lost. System will redeploy if stowed due to
environment condition and “unattended Operation” is enabled, system will try to redeploy
according to configured unattended time
.
D
- Disabled
E
- Enabled
7.10.9.
PW
Fig. 39:
Controller and Web GUI Password
1- Current LCD and Web Interface Password
The user may change this password by using the “↓” and “↑” buttons on the front panel of the 7710
controller and the “→” and “←” buttons to navigate through the character fields. This password must be
remembered in order for the user to re-enter the LCD screen configuration interface, or the web interface.
7.10.10.
SG
This menu will allow the user to configure the subnet mask IP address and the Gateway IP address of the
iNetVu
®
7710 Controller.
Fig. 40:
SG (Gateway) Configuration
1 – S_IP (iNetVu
®
7710 Controller’s Subnet Mask IP Address – Default is (255.255.255.0)
2 – Gateway IP Address (Default: 192.168.0.32) this can be changed to support the network you are on.
PWD :: password
1
S_IP : 255.255.255.0
G_IP: 192.168.0.32
1
2