background image

C.B.S.

œ

Scientific Co, Inc. 

8

 Semi-Dry 

Blotters 

 
B. Semi-Dry Electro-Blotting of DS DNA from Agarose Gels (Southern)

 

 
1.  

Preparation for Southern Blotting 

a.  Agarose gels 20cm x 20cm and up to 6mm thick may be run in this 

system.  Thicker gels require longer transfer times.  Prior to transfer, gels 
should be stained with Ethidium Bromide. Ethidium bromide is a Mutagen.  

ALWAYS 

wear gloves.  Dispose of solutions in accordance with the 

safety regulations of your institution. 

b.  Optionally, depurinate the gel by soaking in 0.25M HCl for 20 minutes.  

Depurination can increase transfer efficiency.  To denature the DNA in 
the gel before transfer, soak in 0.5M NaOH, 1.0M NaCl for 20 minutes.  
Neutralize 2X for 15 minutes in 0.5M Tris-HCl, pH 7.4, 1.5M NaCl. 

c.  Membrane selection: Nylon or nylon supported nitrocellulose.  

ALWAYS

 

use forceps to handle membranes.  If nylon is not base resistant, 
denature DNA prior to transfer. If it is, you may base wash the DNA after 
transfer instead of denaturing before.  Base wash for 30 min. in 0.1N 
NaOH followed by suspension in 0.2M Tris-base, pH 8.0, 0.5% SDS for 
30 minutes to neutralize the membrane. 

 

2.  

Preparation of the Transfer Materials 

a.  

Required Materials: Membrane, cut to exact size of gel; saturate in ddH

2

for ten minutes, then in 0.1X TAE or 0.3X TBE for 20 minutes. 

b.  

Gels should be soaked in running buffer, 0.1XTAE or 0.3XTBE for 20-60 
minutes depending on thickness (3-6mm). 

c.  

Cut eight sheets of 3mm blotter paper (Whatman

) the exact size of the 

gel.  Saturate all eight sheets in running buffer. 

d.  

Mylar Mask: Prepare a mask by cutting a rectangular hole that is slightly 
smaller (1-2mm) than the gel dimensions. 

e.  

For transfer of ssDNA (acrylamide): use 0.5 –1X TBE buffer.  Equilibrate 
in transfer buffer for 15 minutes. 

 

3.  

Stacking of components into Electro-Blotter Apparatus: 

a.  

Insert the mylar mask over the bottom platinum coated titanium electrode 
(anode +).  

Note:

 The bottom electrode is the anode and is fixed in place, 

while the cathode is adjustable and within the lid of the apparatus.  Place 
3-4 pieces of saturated filter paper carefully centered over the cut-out.  
Flatten the filter paper by rolling a glass rod over the surface. 

b.  

Apply a saturated membrane on the top of the paper. 

c.  

Carefully place the gel on the membrane, making sure no bubbles remain 
between the gel/membrane interface. 

d.  

Stack the remaining 3-4 sheets of blotting paper on the top of the gel.  
Add one sheet at a time and be sure to ‘smooth’ with glass rod to remove 
air bubbles. 

e.  

Close the lid which contains the cathode (-).  Holding the two white nylon 
thumbscrews, place the lid over the stack and secure while applying 
some downward pressure (gently!). 

 

4.  

Power Setting 
Connect the unit to the power supply using the power cords supplied.  

Warning:

 

C.B.S. has designed this device such that it cannot be opened unless the power 
cords are disconnected.  DO NOT attempt to open the transfer apparatus without 
disconnecting the power cords and shutting off the power supply.  

 

Содержание EBU-4000

Страница 1: ...Semi Dry Blotting Systems INSTRUCTION MANUAL EBU 4000 EBU 6000...

Страница 2: ...ction 5 1 2 Specifications 5 1 3 Safety 5 Section 2 Description of parts 2 1 Unpacking EBU 4000 or 6000 6 2 2 Components Assembly 6 Section 3 Instructions for Use 3 1 Blotting Unit Preparation 7 11 Se...

Страница 3: ...e highest practical standards of materials workmanship and design C B S Scientific warrants that the product has been tested and will meet or exceed published specifications This warranty is valid onl...

Страница 4: ...endimiento insatisfactorio atribuible a circunstancias fuera del control de C B S Scientific C B S Scientific en ning n caso asumir responsabilidad por da os incidentales o subsecuentes incluyendo en...

Страница 5: ...t passes directly through the gel Use of the mask will increase transfer efficiency and reduce transfer times up to 50 1 2 Specifications Constructions Buffer chamber safety cover Acrylic Electrode pa...

Страница 6: ...nts Blotting chamber with stainless steel cathode and platinum coated anode Safety cover with power leads Mylar sheets for shielding uncovered portion of anode 2 2 Components Assembly SAFETY COVER POW...

Страница 7: ...is why nylon membranes are generally used uncharged nylon being preferable to positively charged nylon Nylon is the membrane of choice because it will bind DNA fragments as small as 50bp and can be ir...

Страница 8: ...g on thickness 3 6mm c Cut eight sheets of 3mm blotter paper Whatman the exact size of the gel Saturate all eight sheets in running buffer d Mylar Mask Prepare a mask by cutting a rectangular hole tha...

Страница 9: ...ng a rectangular hole that is slightly smaller 1 2mm than the gel dimensions b Prepare 8 pieces of Whatman 3mm chromatography paper the exact size of the gel Larger pieces of filter paper may promote...

Страница 10: ...At the conclusion of the run turn power supply off and disconnect leads from blotter Cover will not release unless power cord is removed Remove the cover slowly to catch any part of the gel sandwich...

Страница 11: ...lowed by the gel and 5 more pieces of saturated filter paper Again roll a glass rod over the filter paper stack to compress and remove trapped air bubbles The lid of the apparatus containing the catho...

Страница 12: ...sis 86 315 327 VCH Weinheim Germany 3 Dunn S D Effects of the modification of transfer buffer composition and the renaturation of proteins in gels on the recognition of proteins on Western blots by mo...

Страница 13: ...lpyrocarbonate DEPC treated water for extended periods at 37 C Electrostatic charge and heat affix the conductive platinum surface covering the titanium It can be scratched off or damaged by using sha...

Страница 14: ...t Item EBU 4000 Semi Dry Blotting System Includes power leads and safety interlock 20cm x 20cm EBU 6000 Semi Dry Blotting System Includes power leads and safety interlock 35cm x 45cm MM 4000 Mylar Mas...

Страница 15: ...NOTES...

Страница 16: ...d online ordering www cbsscientific com E mail address sales cbssci com Mailing address C B S Scientific Company P O Box 856 Del Mar CA 92014 Shipping address C B S Scientific Company 10805 Vista Sorr...

Отзывы: