Electroplating
To plate small areas (gilding, galvanising, chrome plating etc.), set the program to electroplating and select by
pressing the control button.
For electroplating the digital display should show the following voltage as shown in the attached
technical datasheet. You can adjust the voltage by tuning the control knob accordingly.
Use a strip of the supplied cleaning felt by attaching the strip to the carbon stamp using the O-ring provided.
The felt strips will wear with prolonged use. To avoid short-circuiting the machine,
replace worn felt strips accordingly.
The stamp is connected using the accompanying black ground cable to the black connector of the machine.
The red-marked ground wire must be connected to the work-piece via the ground clamp.
Moisten the felt uniformly using a little of the correct plating electrolyte and wipe across the area to be plated
a few time.
Working with chemicals can lead to hazards. It is required to wear an acid apron,
tightly fitting acid resistant goggles and gloves. It is also required to have sufficient
extraction/ventilation around the work piece or to wear a suitable respirator.
Please refer to the safety data sheets of the individual electrolytes.
For further information please see the ECME manual, which contains further safety precautions to observe and
application examples.