List of supplied par
List of supplied par
List of supplied par
List of supplied par
List of supplied parts
ts
ts
ts
ts
Connection module
Connection module
Connection module
Connection module
Connection module with
1
1
1
1
1 Threaded joint with seal
2
2
2
2
2 Screw connection with coupling ring and seal
3
3
3
3
3 Locking ring
Connection module DR
Connection module DR
Connection module DR
Connection module DR
Connection module DR with
1
1
1
1
1 Threaded joint with seal
2
2
2
2
2 Screw connection with coupling ring and seal
3
3
3
3
3 Locking ring
4
4
4
4
4 Connection for optional manometer
6
6
6
6
6 Back pressure manometer
7
7
7
7
7 Spring hood
8
8
8
8
8 Display for back pressure setting
9
9
9
9
9 Locking screw
10
10
10
10
10 Rotary button for pressure reducer
11
11
11
11
11 Valve insert
12
12
12
12
12 Sliding ring
Connection module HWS
Connection module HWS
Connection module HWS
Connection module HWS
Connection module HWS with
1
1
1
1
1 Threaded joint with inspection screw and seal
2
2
2
2
2 Screw connection with coupling ring and seal
3
3
3
3
3 Locking ring
4
4
4
4
4 Connection for optional manometer
5
5
5
5
5 Non-return valve with inspection screw
6
6
6
6
6 Back pressure manometer
7
7
7
7
7 Spring hood
8
8
8
8
8 Display for back pressure setting
9
9
9
9
9 Locking screw
10
10
10
10
10 Rotary button for pressure reducer
11
11
11
11
11 Valve insert
12
12
12
12
12 Sliding ring
Intended use
Intended use
Intended use
Intended use
Intended use
The connection module allows you to connect
filters, water softening units, dosing devices and
physical water treatment units quickly. They can
be installed horizontally or vertically.
Installation
Installation
Installation
Installation
Installation
Insert the threaded joint and coupling ring with
the insert into the water pipeline and tighten the
screw connection.
Place the seals into the connection module and
secure the connection module between the
threaded joint and the insert.
See Fig. 3 for the positioning of the DR module
and the manometer.
1. Turn the locking ring to the left limit stop.
2. Press the prongs of the device into the
spaces provided and then rotate the device
45° clockwise to the limit stop.
3. Pull the locking ring with both hand towards
the device until it clicks into place. The
device cannot now be rotated
unintentionally.
To release the device, press the locking ring
together at both sides and push it towards the
connection module.
Operation
Operation
Operation
Operation
Operation
See Fig. 5 on how to connect the device
Figure 1 and 4 DR and HWS only
Figure 1 and 4 DR and HWS only
Figure 1 and 4 DR and HWS only
Figure 1 and 4 DR and HWS only
Figure 1 and 4 DR and HWS only
The pressure reducer is set to 4 bar back pres-
sure ex works. To change the back pressure,
loosen the locking screw (9
9
9
9
9) and turn rotary button
(10
10
10
10
10).
The back pressure can be changed by turning
the adjusting button (range 1.5 - 6 bar).
Turn the button clockwise to increase the back
pressure.
Turn the button anticlockwise to reduce the back
pressure.
The back pressure setting displayed (8
8
8
8
8) is an
approximate value. The manometer (6
6
6
6
6) displays
the exact pressure. A draw-off faucet downstream
of the pressure reducer must be opened and
closed briefly several times while setting the value.
The back pressure drops temporarily when water
is drained.
The back pressure may not exceed 80% of the
pick-up pressure of the hot water safety valve (DIN
1988).
Check the non-return valve (once annually as per
Check the non-return valve (once annually as per
Check the non-return valve (once annually as per
Check the non-return valve (once annually as per
Check the non-return valve (once annually as per
DIN 1988, Section 8)
DIN 1988, Section 8)
DIN 1988, Section 8)
DIN 1988, Section 8)
DIN 1988, Section 8)
HWS only
HWS only
HWS only
HWS only
HWS only
Place bucket under device. Close the shut-off
device upstream of the connection module HWS
and remove the inspection screw (5
5
5
5
5). If the non-
return valve has closed properly, only a small
amount of water escapes, and there is no
continuous flow of water. Tighten the inspection
screw again (5