background image

GasAlertMicroClip

Specifications

25

Approvals:

Approved by CSA to both U.S. and Canadian Standards
CAN/CSA C22.2 No. 157 and C22.2 152
ANSI/UL - 913 and ANSI/ISA - 12.13.01 Part 1

CSA

 

Class I, Division 1, Group A, B, C, and D

ATEX

 CE 

0539 

g

 II 1 G Ex ia IIC T4 Ga 

Sira 13ATEX2330
EN 60079-0, EN 60079-11, and EN 60079-26

IECEx

Ex ia IIC T4 Ga IECEx CSA 05.0015
IEC 60079-0, IEC 60079-11, IEC 60079-26

KTL

GasAlertMicroClip XT: 12-KB4BO-0053

              

GasAlertMicroClip XL: 14-KB4BO-0659X

EAC Certificate: 

RU 

С

-G

В

.

ГБО

5.

В

.00784

I

This equipment has been tested and found to comply with the limits 
for a Class B digital device, pursuant to Part 15 of the FCC Rules 
and ICES-003 Canadian EMI requirements. These limits are 
designed to provide reasonable protection against harmful 
interference in a residential installation. This equipment generates, 
uses and can radiate radio frequency energy and, if not installed and 
used in accordance with the instructions, may cause harmful 
interference to radio communications. However, there is no 
guarantee that interference will not occur in a particular installation. If 
this equipment does cause harmful interference to radio or television 
reception, which can be determined by turning the equipment off and 
on, the user is encouraged to try to correct the interference by one or 
more of the following measures:

• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and receiver.
• Connect the equipment into an outlet on a circuit different from 

that to which the receiver is connected.

• Consult the dealer or an experienced radio/TV technician for 

help.

www.

GlobalTestSupply

.com

Find Quality Products Online at:

[email protected]

Содержание microclip x3

Страница 1: ...1 1 2 3 and 4 Gas Detector Operator s Manual www GlobalTestSupply com Find Quality Products Online at sales GlobalTestSupply com...

Страница 2: ...ding operator s manuals What s In a Box Detector Calibration Cap Battery Charging Adapter Documentation Kit Zeroing the Sensors To zero the sensors refer to steps 1 3 in Calibration on page 7 ec Warni...

Страница 3: ...sor using the appropriate gas Only the combustible gas detection portion of this instrument has been assessed for performance by CSA International Calibrate only in a safe area that is free of hazardo...

Страница 4: ...omettre la protection offerte par le d tecteur Lisez les mises en garde suivantes avant d utiliser le d tecteur a Mises en garde Avertissement Le remplacement d un composant de l appareil peut comprom...

Страница 5: ...e la limite d chelle sup rieure risquant donc d tre dangereuse Une exposition prolong e du GasAlertMicroClip XT certaines concentrations de gaz combustibles et dans certaines atmosph res peut nuire l...

Страница 6: ...iFlash 2 Visual alarm indicators LEDs 3 Alligator clip 4 Charging connector IR interface 5 Pushbutton 6 Carbon monoxide CO sensor 7 Hydrogen sulfide H2S sensor 8 Oxygen O2 sensor 9 Combustible LEL sen...

Страница 7: ...2 Item Description 1 Alarm condition 2 Automatically zero sensor 3 Numeric value 4 Stealth mode 5 Battery life indicator 6 Gas identifier bars 7 Gas cylinder 8 Automatically span sensor www GlobalTest...

Страница 8: ...T To initiate calibration deactivate the detector Press and hold C while the detector performs the OFF countdown Continue holding C while the LCD briefly deactivates and then begins the CAL countdown...

Страница 9: ...damp cloth Do not use soaps polishes or solvents Below are common products to avoid using around sensors Cleaners and Lubricants Brake cleaners Lubricants Rust inhibitors Window and glass cleaners Dis...

Страница 10: ...CAL countdown Continue holding C until the countdown is complete to enter calibration 5 The LCD displays CAL DUE Next a screen displays showing the number of days remaining before calibration is due...

Страница 11: ...GasAlertMicroClip Operator s Manual 10 Attach the Gas Cylinder to the Detector www GlobalTestSupply com Find Quality Products Online at sales GlobalTestSupply com...

Страница 12: ...ibration cap 3 Attach the calibration cap to the detector 4 Apply gas Verify the visual and audible alarms activate 5 Close the regulator and remove the calibration cap from the detector NOTE The dete...

Страница 13: ...Slow siren Slow alternating flash L and gas bar flash Vibrator alarm activates High Alarm Fast siren Fast alternating flash L and gas bar flash Vibrator alarm activates STEL Alarm Fast siren Fast alte...

Страница 14: ...arm the Automatic Shutdown Alarm sequence begins OFF displays before deactivating Automatic Shutdown Alarm Sequence of 10 rapid sirens and alternating flashes with 1 second of silence in between seque...

Страница 15: ...tically zeros the H2S CO and LEL sensors during the startup self test LEL By Volume CH4 When enabled the LEL reading is displayed as vol assuming a methane environment O2 Auto Calibration on Startup W...

Страница 16: ...60 seconds to define how often IntelliFlash occurs and the detector beeps Intelliflash and or Confidence Beep must be enabled in order to define Confidence Beep and IntelliFlash Interval Language Sele...

Страница 17: ...er to the detector IR interface 3 Charge the battery 4 Charge the battery after each workday Item Description 1 Detector 2 IR and charger interface 3 Charging adapter 4 Charging Cable www GlobalTestSu...

Страница 18: ...he exterior with a soft damp cloth Do not use solvents soaps or polishes Replacing a Sensor or Sensor Filter a Warning To avoid personal injury use only sensors specifically designed for the detector...

Страница 19: ...r It may be stuck to the sensors 3 Pull the liner tab if present to remove the liner from the sensor filter Do not fold the sensor filter 4 Verify that the black gasket is facing the front shell and t...

Страница 20: ...the sensor filter is stuck to the sensors remove and replace the sensor filter into the front shell 2 Slide the sensors out Note Detectors that are configured for 1 2 or 3 gases may contain a dummy se...

Страница 21: ...age occurs to the battery 3 Lift the PCB straight up The oxygen sensor will stay in the front shell Remove the sensor 4 On roughly the same spot on the front shell place the new sensor Lower the PCB o...

Страница 22: ...Remove the sensor 4 On roughly the same spot on the front shell place the new sensor Lower the PCB over the oxygen sensor 5 Carefully replace the circular rigidified flex PCB atop the metal sensor po...

Страница 23: ...rly to prevent cross threading Turn the screw counter clockwise until a click is heard and then begin tightening the screw clockwise 6 When replacing the screws they must be seated properly to prevent...

Страница 24: ...sor or oxygen pump Alarm conditions TWA alarm STEL alarm low alarm high alarm multi gas alarm over limit OL alarm low battery alarm confidence beep automatic shutdown alarm Audible alarm 95 dB at 30 c...

Страница 25: ...e battery Temperature code Lithium polymer 20 C Ta 50 C T4 Battery charger GasAlertMicroClip charging adapter a Warning Charge only in a safe area that is free of hazardous gas and within temperatures...

Страница 26: ...armful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmf...

Отзывы: