GasAlertMicroClip
Alarms
13
Alarm
Display
Alarm
Display
Sensor Alarm
•
During startup Error
[sensor name]
displays
• During normal operation Err
displays
Confidence Beep and IntelliFlash
• One beep and flash every second
Note: Confidence Beep and
IntelliFlash automatically
deactivate during low battery
alarm, self-test fail, calibration fail,
bump test fail, or an alarm event.
Low Battery Alarm
• Sequence of 10 rapid sirens and
alternating flashes with 7 seconds of
silence in between (continues for
15 minutes)
•
and
L
flash,
LOW BAT
displays, and the vibrator alarm activates
• After 15 minutes of the Low Battery
alarm, the Automatic Shutdown Alarm
sequence begins
•
OFF
displays before deactivating
Automatic Shutdown Alarm
• Sequence of 10 rapid sirens and
alternating flashes with 1 second of
silence in between (sequence reactivates
seven times)
•
LOW BAT
and
L
display, and
vibrator alarm activates
•
OFF
displays before deactivating
Note: Alarms can be set to latching or non-latching. To enable/disable
latching, select/deselect Latching Alarms in Fleet Manager II. Local
regulations may require a latching alarm.
If Low Alarm Acknowledge is enabled and a low alarm occurs, press
C
to disable the audible alarm. The visual and vibrator alarms remain
activated. If the alarm escalates to a high, STEL, or TWA alarm, the
audible alarm reactivates.
www.
GlobalTestSupply
.com
Find Quality Products Online at: