background image

Limited Warranty & Limitation of Liability 

 
BW Technologies LP (BW) warrants this product to be free from defects in material and workmanship under normal use and service for a 
period of two years, beginning on the date of shipment to the buyer. This warranty extends only to the sale of new and unused products to 
the original buyer. BW’s warranty obligation is limited, at BW’s option, to refund of the purchase price, repair, or replacement of a defective 
product that is returned to a BW authorized service center within the warranty period. In no event shall BW’s liability hereunder exceed the 
purchase price actually paid by the buyer for the Product. This warranty does not include: 

a) 

fuses, disposable batteries or the routine replacement of parts due to the normal wear and tear of the product arising from 
use; 

b) 

any product which in BW’s opinion, has been misused, altered, neglected or damaged by accident or abnormal conditions of 
operation, handling or use; 

c) 

any damage or defects attributable to repair of the product by any person other than an authorized dealer, or the installation 
of unapproved parts on the product; or 

The obligations set forth in this warranty are conditional on: 

a) 

proper storage, installation, calibration, use, maintenance and compliance with the product manual instructions and any other 
applicable recommendations of BW; 

b) 

the buyer promptly notifying BW of any defect and, if required, promptly making the product available for correction. No 
goods shall be returned to BW until receipt by the buyer of shipping instructions from BW; and 

c) 

the right of BW to require that the buyer provide proof of purchase such as the original invoice, bill of sale or packing slip to 
establish that the product is within the warranty period. 

THE BUYER AGREES THAT THIS WARRANTY IS THE BUYER’S SOLE AND EXCLUSIVE REMEDY AND IS IN LIEU OF ALL OTHER 
WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTY OF MERCHANTABILITY OR 
FITNESS FOR A PARTICULAR PURPOSE. BW SHALL NOT BE LIABLE FOR ANY SPECIAL, INDIRECT, INCIDENTAL OR 
CONSEQUENTIAL DAMAGES OR LOSSES, INCLUDING LOSS OF DATA, WHETHER ARISING FROM BREACH OF WARRANTY OR 
BASED ON CONTRACT, TORT OR RELIANCE OR ANY OTHER THEORY. 
Since some countries or states do not allow limitation of the term of an implied warranty, or exclusion or limitation of incidental or 
consequential damages, the limitations and exclusions of this warranty may not apply to every buyer. If any provision of this warranty is 
held invalid or unenforceable by a court of competent jurisdiction, such holding will not affect the validity or enforceability of any other 
provision. 

Contacting BW Technologies by Honeywell 

USA: 1-888-749-8878 

Canada: 1-800-663-4164 

Europe: +44 (0) 1295 700300 

Other countries: +1-403-248-9226 

 
Email us at: 

[email protected]

Visit BW Technologies by Honeywell’s web site at: 

www.gasmonitors.com

 

Содержание GasAlertMicroClip

Страница 1: ......

Страница 2: ...ations of BW b the buyer promptly notifying BW of any defect and if required promptly making the product available for correction No goods shall be returned to BW until receipt by the buyer of shippin...

Страница 3: ...uages are displayed on the detector and in the corresponding Quick Reference Guide Safety Information Read First Use the detector only as specified in this guide otherwise the protection provided by t...

Страница 4: ...at the audible and visual alarms are activated Calibrate if the readings are not within the specified limits Caution High off scale readings may indicate an explosive concentration Any rapid up scalin...

Страница 5: ...ts of the GasAlertMicroClip Parts of the GasAlertMicroClip Item Description 1 Visual alarm bars LED 2 Liquid crystal display LCD 3 Audible alarm 4 Sensors 5 Pushbutton 6 Charging connector IR interfac...

Страница 6: ...ck Reference Guide Display Elements Item Description 1 Alarm condition 2 Automatically span sensor 3 Gas cylinder 4 Gas identifier bars 5 Battery life indicator 6 Stealth mode 7 Numeric value 8 Automa...

Страница 7: ...To clear the TWA STEL and MAX readings press C when the LCD displays RESET To initiate calibration press and hold C as the detector executes the OFF countdown and continue to hold C as the LCD briefly...

Страница 8: ...tector completes the span 2 The detector then activates again and performs the CAL countdown Continue to hold C until the countdown is complete to enter calibration 5 The LCD then displays CAL DUE It...

Страница 9: ...GasAlertMicroClip Attach the Gas Cylinder to the Detector Attach the Gas Cylinder to the Detector 7...

Страница 10: ...ash L and target gas bar flash Vibrator alarm activates High Alarm Fast siren Fast alternating flash L and target gas bar flash Vibrator alarm activates STEL Alarm Fast siren Fast alternating flash L...

Страница 11: ...ting access the latching alarms option in the GasAlertMicroClip Soft Tools software Local regulations may require a latching alarm If the detector is in stealth mode it only vibrates in alarm mode the...

Страница 12: ...sensors only STEL Alarm The short term exposure limit STEL alarm setpoint toxic sensors only STEL Interval Changes the short term exposure limit 5 15 minutes applicable to toxic sensors only Auto Zero...

Страница 13: ...ration upon start up The detector must be charged in a non hazardous atmosphere of 0 C 45 C 32 F 113 F To reach full battery capacity allow the battery to fully charge and fully discharge three times...

Страница 14: ...ular intervals Keep an operations log of all maintenance bump checks calibrations and alarm events Clean the exterior with a soft damp cloth Do not use solvents soaps or polishes Replacing a Sensor or...

Страница 15: ...PCB and remove the PCB Note Ensure the battery does not get damaged once the PCB is removed 4 Remove the old sensor filter or slide pull out the old sensor s 5 Insert a new sensor filter or sensor s...

Страница 16: ...bustible sensor with 5 accuracy Ensure the rib on the interior of the rear shell fits between the battery pack and the PCB as shown in the following figure Storage temperature 40 C to 50 C 40 F to 122...

Страница 17: ...ce bump bump interval bump due lock stealth mode IR stealth mode language selection enable disable automatic oxygen calibration enable disable auto zero at start up set alarm setpoints set span concen...

Страница 18: ...ns may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference...

Страница 19: ...hnologies 2006 all rights reserved Printed in Canada All product names are trademarks of their respective companies Quick Reference Guide GasAlertMicroClip H2S CO O2 Combustibles 1 2 3 and 4 Gas Detec...

Страница 20: ...confirm their ability to respond to gas by expos ing the detector to a gas concentration that exceeds the alarm setpoints Manually verify that the audible and visual alarms are activated If any senso...

Отзывы: