15.1.1 Lower weight limit
Correction weight below a certain limit is normally
shown equal to zero. This limit can be set from 10 g
to 1 g.
At the end of the spin however, by pressing the button
, the weight can be displayed with max resolution
of 1 g, not considering the set lower limit.
IN THE PLANT, THE LOWER LIMIT
FOR THE DYNAMIC WHEEL BAL-
ANCING MODE IS SET TO 5 g.
THE LOWER LIMIT FOR ALL THE
OTHER MODES IS SET TO 7 g.
1
KEY
1 – Lower weight limit in the DYNAMIC program to
display "OK" (default value 5 g)
2 – Lower weight limit in the ALU-STATIC program
to display "OK" (default value 7 g)
3 – Weights display resolution (default value 5 g)
4 – Weight % reduction in the ECO-WEIGHT function
(0 ÷ 200) (default value 100)
2
3
4
15.1.2 Setting adhesive weight dimensions
and static threshold percentage
To ensure the balancing machine precisely calculates
the dimensions and total adhesive weights, set the
height (thickness) and width of the adhesive weights
at your disposal (see
Fig. 63
).
Fig. 63
To carry out this setting, press the icon
. You
will see the following screen:
KEY
1 – Weights thickness (height) (default value 4 mm)
2 – Weights width (default value 19 mm)
1
2
From this screen page, change the size values of weights
using the buttons
and
.
THE BLUE-COLOURED-VALUE
IS THE ACTIVE FIELD AND THE
MODIFIABLE ONE.
1297-M008-4_B