![BUSKRO BK7IB-2 Скачать руководство пользователя страница 92](http://html.mh-extra.com/html/buskro/bk7ib-2/bk7ib-2_user-manual_2835654092.webp)
Appendix E
AC Motor Drive Settings
Page C-8
Buskro Ltd.
BK7IB-2
C.3.4 Group 3: Output Function Parameters
Table C-4:
Parameters
Functions
Settings
Buskro
Setting
3-00
Desired freq, attained
1.0 ~ 400 Hz
1.0
3-01
Terminal count value
0 ~ 999
0
3-02
Preliminary count value
0 ~ 999
0
3-03
Multi-function (relay
output)
0: not used
1: AC drive operational
2: Max. Output Freq. Attained
3: Zero Speed
4: Over Torque
5: Base-Block (B.B.)
6: Low Voltage Detection
7: AC Drive Operation Mode
8: Fault Indication
9: Desired Freq. Attained
10: PLC Program Running
11: PLC Program Step Complete
12: PLC Program Complete
13: PLC Program Operation Pause
14: Terminal Count Value Attained
15: Preliminary Count Value Attained
16: Ready State Indicator
8
C.3.5 Group 4: Input Function Parameters
Table C-5:
Parameters Functions
Settings
Buskro
Setting
♣
4-00
Potentiometer bias freq.
0.0 ~ 350Hz
0.0
♣
4-01
Potentiometer bias polarity
0: positive bias
1: negative bias
0
♣
4-02
Potentiometer freq. gain
1 ~ 200%
100
4-03
Potentiometer reverse
motion enable
0: not used
1: reverse motion enable
2: forward motion only
0
4-04
Multi-function input
terminal 1 (M1)
(d O ~ d 20)
0: not used
1: M0: FWD/STOP, M1: REV/STOP
2: M0: RUN/STOP, M1: FWD/REV
2
4-05
Multi-function input
terminal 2 (M2)
3: M0, M1, M2: 3-wire operation control
mode
6
Содержание BK7IB-2
Страница 1: ...BK7IB 2 Inline Base Part No 9105171 User s Guide V1 0 ...
Страница 5: ...General Information Buskro Ltd BK7IB Inline Base Chapter 1 1 0 General Information ...
Страница 13: ...Operator Instructions Buskro Ltd BK7IB Inline Base Chapter 2 2 0 Operator Instructions ...
Страница 22: ...BK7IB 2 Integration Buskro Ltd BK7IB Inline Base Chapter 3 3 0 BK7IB Integration ...
Страница 25: ...Electrical System Buskro Ltd BK7IB Inline Base Chapter 4 4 0 Electrical System ...