5 | Installation
10 | 40
Instruction Manual R5 RD 0200-0360 A_EN_en
5
Installation
5.1
Installation Conditions
NOTICE
Use of the machine outside of the permitted installation conditions.
Risk of premature failure!
Loss of efficiency!
●
Take care that the installation conditions are fully complied with.
~10 cm
~30 cm
~50 cm
~5 cm
~30 cm
~10 cm
~10 cm
~50 cm
~20cm
~30 cm
1
2
Description
1
Standard version
2
Version with cooling air deflector
(optional)
●
Make sure that the environment of the machine is not potentially explosive.
●
Make sure that the ambient conditions comply with the Technical Data [
●
Make sure that the environmental conditions comply with the protection class of the motor and
the electrical elements.
●
Make sure that the installation space or location is protected from weather and lightning.
●
Make sure that the installation space or location is vented such that sufficient cooling of the
machine is provided.
●
Make sure that cooling air inlets and outlets are not covered or obstructed and that the cooling
air flow is not affected adversely in any other way.
●
Make sure that the oil sight glass (OSG) remains easily visible.
●
Make sure that enough space remains for maintenance work.
●
Make sure that the machine is placed or mounted horizontally, a maximum of 1° in any direction
is acceptable.
●
Even 0.5° in longitudinal direction, in case of a level switch is being used in.
●
Check the oil level, see Oil Level Inspection [
25].
●
Make sure that all provided covers, guards, hoods, etc. are mounted.
Version with water-oil heat exchanger:
●
13].