Technical Data | 13
Instruction Manual R5 RD 0200-0360 A_EN_en
35 | 40
13
Technical Data
RD 0200 A
RD 0240 A
Nominal pumping speed
(50Hz / 60Hz)
m³/h
160 / 190
200 / 240
ACFM
94 / 112
118 / 141
Ultimate pressure
(without gas ballast valve)
hPa (mbar) abs.
0.1
TORR
0.075
Ultimate pressure
(with gas ballast valve)
hPa (mbar) abs.
0.5
TORR
0.375
Nominal motor speed
(50Hz / 60Hz)
min
-1
1500 / 1800
RPM
Permitted motor speed range
min
-1
1200 … 1800
RPM
Nominal motor rating
(50Hz / 60Hz)
kW
3.0 / 4.2
4.0 / 4.2
HP
- / 5.6
- / 5.6
Power consumption at 100 mbar –
75 TORR (50Hz / 60Hz)
kW
2.9 / 3.8
3.5 / 4.3
HP
- / 5.1
- / 5.4
Power consumption at ultimate
pressure (50Hz / 60Hz)
kW
1.9 / 2.3
2.0 / 2.5
HP
- / 3.1
- / 3.4
Noise level (ISO 2151)
(50Hz / 60Hz)
dB(A)
68 / 70
68 / 72
Water vapor tolerance max. (with
gas ballast valve) (50Hz / 60Hz)
hPa (mbar)
40 / 100
TORR
- / 75
Water vapor capacity (with gas
ballast valve) (50Hz / 60Hz)
kg / h
4,0 / 8,3
5,2 / 11,4
Lbs. / h
8.8 / 18.3
11.5 / 25.1
Max. allowable pressure in the oil
mist separator
hPa (mbar) abs.
1600
TORR
1200
Max. allowable gas inlet
temperature
°C
≤
50 hPa (mbar) abs.
►
150
°F
≤
37.5 torr
►
302
°C
>
50 hPa (mbar) abs.
►
80
°F
>
37.5 torr
►
176
Ambient temperature range
°C
5 ... 40
°F
41 … 104
Ambient pressure
Atmospheric pressure
Oil capacity
L
7
qts.
7.5
Weight approx.
Kg
175
Lbs.