5 | Installation
8 / 28
0870569784_RA_RC1000-1600B_-0003_IM_en
5
Installation
5.1 Installation Conditions
~50 cm
~50 cm
~100 cm
~100 cm
• Make sure that the environment of the machine is not potentially explosive.
• Make sure that the ambient conditions comply with the
Technical Data [
}
23]
.
• Make sure that the environmental conditions comply with the protection class of the
motor.
• Make sure that the installation space or location is vented such that sufficient cooling
of the machine is provided.
• Make sure that cooling air inlets and outlets are not covered or obstructed and that
the cooling air flow is not affected adversely in any other way.
• Make sure that the oil sight glass (OSG) remains easily visible.
• Make sure that enough space remains for maintenance work.
• Make sure that the machine is placed or mounted horizontally, a maximum of 1° in
any direction.
• Check the oil level, fill up if necessary, see
Filling Oil [
}
11]
.
• Make sure that all provided covers, guards, hoods, etc. are mounted.
Version with water-oil heat exchanger:
• Make sure that the cooling water complies with the requirements, see
Cooling
Water Connection (Optional) [
}
10]
.
If the machine is installed at an altitude greater than 1000 meters above sea level:
• Contact your Busch representative, the motor should be derated or the ambient
temperature limited.
5.2 Connecting Lines / Pipes
• Make sure that the connection lines cause no stress on the machine‘s connection, if
necessary use flexible joints.
• Make sure that the line size of the connection lines over the entire length is at least as
large as the connections of the machine.