Storage | 4
0870201062_RA1000-1600B_Ex_-0007_IM_en
11 / 40
4
Storage
• Seal all apertures with adhesive tape or reuse provided caps.
Version with water-oil heat exchanger:
• Make sure that the cooling water has been completely removed, see
.
If the machine is to be stored for more than 3 months:
• Wrap the machine in a corrosion inhibiting film.
• Store the machine indoors, dry, dust free and if possible in original packaging
preferably at temperatures between 0 ... 40 °C.
5
Installation
5.1 Installation Conditions
WARNING
The installation conditions are not respected in an ATEX environment.
Risk of severe injury!
Risk of explosion!
• Take care that the installation conditions are met.
NOTICE
Use of the machine outside of the permitted installation conditions.
Risk of premature failure!
Loss of efficiency!
• Take care that the installation conditions are fully complied with.
~50 cm
~50 cm
~100 cm
~100 cm
• Make sure that the environment of the machine complies with the ATEX classification
of the machine according to the data given on the nameplate of the motor and the
nameplate of the machine (NP).
• Make sure that the ambient conditions comply with the
• Make sure that the environmental conditions comply with the protection class of the
motor and the electrical instruments.