5 | Installation
20 / 40
0870201062_RA1000-1600B_Ex_-0007_IM_en
5.7.1 Wiring Diagram Temperature Switch
Part no.:
0651 538 812
Supplier reference:
Trafag 414
P&ID position:
TS+/0101 “gas temp.”
TS+/0102 “gas temp.” (optional)
TS+/0103 “gas temp.” (optional)
TS+/0104 “oil temp.” (optional)
2
1
T
1 = Brown ; 2 = White
Electrical data:
U
i
= 24 VDC ; I
i
= 100 mA ; P
i
= 0.6 W ; L
i
= 0 µH ; C
i
= 0 pF
Contact:
Normally closed
Switch point:
(factory default adjustment)
T
trip
(TS+/0101) = 130°C ; T
trip
(TS+/0102) = 110°C ; T
trip
(TS+/0103) = 110°C
T
trip
5.7.2 Wiring Diagram Resistance Thermometer
Part no.:
0651 563 753 (with transmitter)
Supplier reference:
Wika TR31
Connector:
M12x1, 4-pin
P&ID position:
TSA+/0101 “gas temp.”
TSA+/0102 “gas temp.” (optional)
TSA+/0103 “gas temp.” (optional)
TSA+/0104 “oil temp.” (optional)
1
2
4
3
3
1
+
-
1 = Brown ; 3 = Blue
Electrical data:
U
i
= 30 VDC ; I
i
= 120 mA ; P
i
= 750 mW ; L
i
= 0 µH ; C
i
= 29.7 nF
4 ... 20 mA
►
0 ... 150 °C
Warning signal:
T
warning
(TSA+/0101) = 135°C
►
18.4 mA
T
warning
(TSA+/0102) = 105°C
►
15.2 mA
T
warning
(TSA+/0103) = 105°C
►
15.2 mA
T
warning
Trip signal:
T
trip
(TSA+/0101) = 140°C
►
18.93 mA
T
trip
(TSA+/0102) = 110°C
►
15.73 mA
T
trip
(TSA+/0103) = 110°C
►
15.73 mA
T
trip
(TSA+/0104) = see
5.7.3 Wiring Diagram Pressure Switch
Part no.:
0653 539 030
Supplier reference:
United Electric Controls
H100 (100 Series)
Maintenance procedure:
Procedure B
P&ID position:
PS+/0301
Electrical data:
U
i
= 49 VDC ; I
i
= 3 A ; L
i
= 0 µH ; C
i
= 0 pF
Contact:
Normally closed
2
1
P
Switch point:
P (PS+/0301) = 1500 hPa (mbar) abs. (factory default adjustment)