Troubleshooting | 11
0870567093_NC0630C_ACV_A0002_IM_en
33 / 36
The machine runs too hot.
Ambient temperature too
high.
• Observe the permitted
ambient temperature, see
Technical Data [
►
34]
.
The heat exchanger (AHE) is
dirty or obstructed.
• Clean it and make sure
that the air flow path is
clear of all obstacles.
Temperature of the process
gases at the inlet too high.
• Observe the permitted
gas inlet temperature, see
Technical Data [
►
34]
.
The cooling liquid pump is
defective.
• Repair the machine.
Oil level too low.
• Top up oil.
Cooling liquid level too low.
• Top up cooling liquid.
The oil is black.
Oil change intervals are too
long.
• Drain the oil and fill in
new oil, see
Oil Change
[
►
26]
.
The machine runs too hot.
• See problem "The ma-
chine runs too hot".
For the solution of problems not mentioned in the troubleshooting chart contact your
Busch representative.
All manuals and user guides at all-guides.com