background image

u

Clean the leak-protection non-return valve

l

Check the ventilator filter (RF), clean if necessary

If the cooling water line is equipped with a filter:

u

Check the filter and clean or replace if necessary

l

Check the seals and replace if necessary

l

Check the intake and discharge lines and clean or replace if
necessary

Every 16 000 hours of operation, at the latest

after 4 years:

l

Drain the oil (see “Draining the oil”)

l

A main inspection of the vacuum pump (Busch)

Lock Out/ Tag Out procedure

l

Stop the pump with the LCD control (press on STOP button during
10s)

l

Press on emergency stop button

l

Switch off the main circuit breaker

l

Switch off the customer’s power supply

l

Switch off the water and nitrogen quick connections (inlet first,
then outlet)

l

Put the label or warning board “Maintenance processing” on or
next to the pump

Safety Lockout procedure

l

Take off the label or warning board “Maintenance processing”

l

Check the oil level according to the chapter “Checking the oil
level”

l

Switch on the main circuit breaker

l

Release the emergency stop button

l

Switch on the water and nitrogen quick connections (outlet first,
then inlet)

l

Make sure that the “Necessary installation instructions” are
followed

l

Start the pump with the LCD control (press on START button)

Checking the oil

Checking the oil level

l

Make sure that the vacuum pump has been switched off and that
it cannot be switched on again accidentally

l

Indication of the oil level on the various oil sight glasses

If the oil level does not reach the MIN marking:

u

Top up with oil (see “Refilling oil”)

If the oil level exceeds the MAX marking:

u

Check the condensate drain

l

Drain the oil (see “Draining the oil”)

Refilling oil

NOTE

: Oil does not normally have to be refilled outside the

recommended oil change intervals. A drop in the oil level indicates a
fault (see "Alarms and warnings" -> Busch PLC and Busch LCD).

CAUTION

Only fill in oil through the oil filler opening.

CAUTION

Danger of burns when the oil filler cap is open.

Danger of injuries when the oil filler cap is not screwed on properly.

Only unscrew the oil filler cap when the vacuum pump has been
switched off.

The vacuum pump may only be switched on when the oil filler cap
is properly closed and tight.

We recommend submitting the pump to a leakage rate test in order
to ensure the pump is leak tight.

l

Make sure that the vacuum pump has been switched off and that
it cannot be switched on again accidentally

l

Unscrew the oil filler cap (OFP)

l

Fill in oil up to the middle of the oil sight glass

l

Make sure that the oil level lies between the MIN and MAX
markings on the oil sight glasses

l

Make sure that the seals of the filler cap are not damaged and that
they sit properly. Replace them if necessary

l

Screw on the filler cap again

Checking the colour of the oil

NOTE

: The oil must be clear and transparent. A permanent milky

colour is an indication for contamination by foreign bodies. A dark
colour is an indication for oil that has been chemically altered or
contaminated by foreign bodies.

WARNING

Dark colored oil may indicate a hazardous pump condition which
could cause personal injury.

If dark oil similar to the example shown is observed, you have to
contact the Busch Customer Service without delay.

Oil change

DANGER

If the vacuum pump has pumped gases that were contaminated
with foreign bodies that are hazardous to health, the oil is also
contaminated with these foreign bodies.

There is a health hazard when changing contaminated oil.

There is also a danger to the environment.

Wear protective clothing when replacing contaminated oil.

Contaminated oil must be treated specially and must be disposed
of according to applicable regulations.

Maintenance

BC 1000, 2000 F

Page 16

0870760874 (En)

Содержание COBRA BC 1000

Страница 1: ...ro Majang myun Icheon si Gyunggi do 467 813 Republic of Korea 0870760874 0002_en Original instructions Modi cations reserved 02 09 2020 Instruction Manual COBRA Screw Vacuum Pumps BC 1000 2000 F Get t...

Страница 2: ...cuum pump on off 14 First start up of the system 14 Switching the system off 14 Maintenance 15 Maintenance program 15 Weekly 15 Monthly 15 Yearly 15 Every 16 000 hours of operation at the latest after...

Страница 3: ...O OSG Oil sight glass OSG1 Oil sight glass OSG2 Oil sight glass OSG3 Oil sight glass CPC PLC connection MB On off switch Main circuit breaker RF Ventilator VFD1 Variable frequency device VFD2 Variable...

Страница 4: ...BC 1000 2000 F Page 4 0870760874 En VFD2 MOT1 TS2 MOT2 OSG3 VFD1 OSG2 TS1 PSA OSG1 MV CWM CWR DGR1 DGR2 DGF...

Страница 5: ...re more or equal than 150 hPa mbar Caution the operating cycle of 150 hPa mbar must not exceed more than 5 min For other applications contact your Busch representative Maximum inlet pressure 1 bar abs...

Страница 6: ...system The nitrogen system can be used in a number of different ways nitrogen is used as dilution gas It is injected inside the cylinder on two different places Nitrogen flow injected in the middle ho...

Страница 7: ...hen installing the pump in potentially explosive environments The maintenance instructions must be observed and respected It is vital that these installation and maintenance instructions are read and...

Страница 8: ...supply l Switch off the water and nitrogen quick connections inlet first then outlet l Put the label or warning board Maintenance processing on or next to the pump Emergency off circuit description l...

Страница 9: ...to add a belt or rope at a suitable point when lifting the pump l Attach lifting gear securely to the eyebolt or eyebolts l Use lifting gear with a crane hook equipped with safety latch l Lift the vac...

Страница 10: ...ure 2 5 bar relative Water hardness 5 dGH NOTE 1 german degree 1 dGH 1 78 french degree 1 25 e english degree 17 9 mg kg CaCO3 american hardness Minimum flow rate 3 4 l min for the standard version l...

Страница 11: ...least equal to the diameter of the exhaust flange of the vacuum pump to prevent a drop in the performance of the vacuum pump in the case of a smaller cross section l Make sure that the vacuum pump is...

Страница 12: ...ion it can be destroyed even if this is the case for only a short moment Make sure that the vacuum pump is connected correctly before switching it on l Determine rotation sense of the motor by using a...

Страница 13: ...from the intake flange and connect the intake line to the intake flange CAUTION In case of a vacuum pump filled with oil make sure that by lifting the inclination angle of the vacuum pump do not exce...

Страница 14: ...ants will result in damage to the vacuum pump CAUTION The cooling water flow which is checked by the flowmeter CWM must be at least 3 4 l min l Make sure that all caps safeguards and similar covers ar...

Страница 15: ...hat there are no cleaning tools in the pump anymore according to local and national regulations Before pulling off the different connections make sure that the intake and exhaust lines of the vacuum p...

Страница 16: ...l change intervals A drop in the oil level indicates a fault see Alarms and warnings Busch PLC and Busch LCD CAUTION Only fill in oil through the oil filler opening CAUTION Danger of burns when the oi...

Страница 17: ...nd that they do not leak CAUTION Only fill in oil through the oil filler opening l Unscrew the oil filler cap OFP l Fill in oil up to the middle of the oil sight glass l Make sure that the oil level l...

Страница 18: ...ful foreign material These foreign materials can infiltrate the pores recesses and other internal spaces of the vacuum pump Danger to health during dismantling of the vacuum pump Danger to the environ...

Страница 19: ...nditions which could cause personal injury Oil quantity The quantity of oil specified in the following table is of informative nature only Check the oil level with the help of the various oil sight gl...

Страница 20: ...overpressure bar 1 5 Oil quantity l 1 52 Weight kg 310 with silencer at exhaust Technical data BC 2000 F Effective suction capacity m3 h cfm 1580 930 Ultimate pressure Torr mbar 2 25 x 10 3 3 x 10 3...

Страница 21: ...in electrical and electronic equipment and following the standards Person authorised to compile the technical file Gerd Rohweder Busch Dienste GmbH Schauinslandstr 1 DE 79689 Maulburg Icheon si 01 06...

Страница 22: ...Note...

Страница 23: ...Note...

Страница 24: ...l Italy info busch it Japan info busch co jp Korea busch busch co kr Malaysia busch busch com my Mexico info busch com mx Netherlands info busch nl New Zealand sales busch co nz Norway post busch no P...

Отзывы: