CAUTION

When the intake lines have been connected, make sure that the
system does not leak. Leakages of dangerous substances must be
prevented!

l

Make sure that the intake lines are equipped with a shut-off device
upstream of the intake flange so that the flow of sucked gas can
be stopped

l

Make sure that the intake lines do not exercise any force on the
intake flange. Mount bellows if necessary

l

The inlet flange has the following dimension:

BC 1000 F: DN 100 ISO-K

BC 2000 F: DN 160 ISO-K

In the case of long intake lines, the line cross-section should be larger
than the intake flange to prevent a drop in the performance of the
vacuum pump. If you have any doubts, contact your Busch
representative.

Discharge connection

CAUTION

Do not put hands into the outlet aperture.

Risk of body damage!

The following instructions for connection to the discharge only apply if
the sucked gas is discharged by the vacuum pump into a suitable
environment.

l

Make sure that the protection that was attached to prevent
penetration of particles during transport has been removed before
the vacuum pump is connected to the vacuum line

l

Make sure that the nominal diameter of the exhaust line is at least
equal to the diameter of the exhaust flange of the vacuum pump

to prevent a drop in the performance of the vacuum pump in the
case of a smaller cross-section

l

Make sure that the vacuum pump is connected with leakproof lines

CAUTION

When the discharge lines have been connected, make sure that the
system does not leak. Leakages of dangerous substances must be
prevented!

l

Make sure that the discharge line is mounted in such a way that
condensate cannot penetrate into the pump (siphon trap, gradient)

l

Make sure that no shut-off devices are mounted in the discharge
line

l

Make sure that the discharge lines do not exercise any force on the
discharge flange. Mount bellows if necessary

l

The discharge flange has the following dimension:

DN 40 ISO KF

In the case of long discharge lines the line cross-section should be
larger than the discharge flange to prevent a drop in the performance
of the vacuum pump. If you have any doubts, contact your Busch
representative.

Cooling water connection

The cooling water is generally connected with a hose.

The cooling water outlet must be unpressurised.

Connection diameter: 3/8 NPT

Nitrogen connection

The nitrogen is connected with a pipe (leakproof against oxygen).

Connection diameter: 1/4 NPT

BC 1000, 2000 F

Installation and Commissioning

0870760874 (En)

Page 11

䣑䣫䣮䢢䣵䣫䣩䣪䣶䢢䣩䣮䣣䣵䣵

䣇䣯䣧䣴䣩䣧䣰䣥䣻䢢䣵䣶䣱䣲

䣋䣰䣶䣧䣴䣴䣷䣲䣶䣧䣴䢢䣯䣣䣫䣰

䢵䢵䢸

䢳䢲䢴

䣔䣧䣯䣱䣶䣧䢢䣥䣱䣰䣶䣴䣱䣮

䢪䣯䣱䣸䣧䣣䣤䣮䣧䢫

䣋䣰䣮䣧䣶
䣆䣐䢢䢳䢲䢲䢢䣋䣕䣑䢯䣍

䢸䢷䢳

䢷䢳䢸䢰

䢸䢳䢷

䢻䢷䢲

䣅䣱䣰䣶䣴䣱䣮䢢䣤䣱䣺

䢪䣯䣱䣸䣧䣣䣤䣮䣧䢫

䣇䣺䣪䣣䣷䣵䣶
䣆䣐䢢䢶䢲䢢䣋䣕䣑䢯䣍䣈

䢹䢻䢲

䢴䢴䢰

䢵䢴䢷

䢹䢴䢶

䢳䢲䢷䢶

䣘䣧䣰䣶䣫䣮䣣䣶䣫䣰䣩䢢䣦䣷䣥䣶
䢷䢲䢰䢺

䢰䢷

䣁䢳

䢶䢷

䣒䣴䣧䣵䣵䣷䣴䣧䢢䣩䣣䣷䣩䣧

䣒䣴䣧䣵䣵䣷䣴䣧䢢䣴䣧䣩䣷䣮䣣䣶䣱䣴

䣅䣱䣱䣮䣫䣰䣩䢢䣹䣣䣶䣧䣴䢢䣱䣷䣶䣮䣧䣶

䣐䣫䣶䣴䣱䣩䣧䣰䢢䣫䣰䣮䣧䣶

䣅䣱䣱䣮䣫䣰䣩䢢䣹䣣䣶䣧䣴䢢䣫䣰䣮䣧䣶

䢻䢲

䢶䢴䢷

䣒䣱䣹䣧䣴䢢䣥䣱䣰䣰䣧䣥䣶䣱䣴

䣑䣫䣮䢢䣵䣫䣩䣪䣶䢢䣩䣮䣣䣵䣵

䢳䢳䢲䢷䢰䢷

䢸䢹䢲

C.W. OUTLET

C.W. INLET

䣖 䣻䣲䣧

䣐䣱

䣑䣲䣧䣴䣣䣶䣫䣰䣩䢢 䣨䣴䣧䣳䣷䣧䣰䣥䣻䢢䣯䣣䣺䢰

POWER CONNECTOR

䣗䢢䣴䣣䣰䣩䣧
䣒䢢䣴䣣 䣶䣧䣦
䣋䢢䣴䣣䣶䣧䣦
䣋䣯䣣䣺

䣋䣥䣷

䣇䣮䣧䣥䣶䣴䣫䣥䣣䣮
䣵䣥䣪䣧䣯䣣䣶 䣫䣥䣵

N2 REG.

N

©ü

Dimensional drawing BC 1000 F

Содержание COBRA BC 1000

Страница 1: ...ro Majang myun Icheon si Gyunggi do 467 813 Republic of Korea 0870760874 0002_en Original instructions Modi cations reserved 02 09 2020 Instruction Manual COBRA Screw Vacuum Pumps BC 1000 2000 F Get t...

Страница 2: ...cuum pump on off 14 First start up of the system 14 Switching the system off 14 Maintenance 15 Maintenance program 15 Weekly 15 Monthly 15 Yearly 15 Every 16 000 hours of operation at the latest after...

Страница 3: ...O OSG Oil sight glass OSG1 Oil sight glass OSG2 Oil sight glass OSG3 Oil sight glass CPC PLC connection MB On off switch Main circuit breaker RF Ventilator VFD1 Variable frequency device VFD2 Variable...

Страница 4: ...BC 1000 2000 F Page 4 0870760874 En VFD2 MOT1 TS2 MOT2 OSG3 VFD1 OSG2 TS1 PSA OSG1 MV CWM CWR DGR1 DGR2 DGF...

Страница 5: ...re more or equal than 150 hPa mbar Caution the operating cycle of 150 hPa mbar must not exceed more than 5 min For other applications contact your Busch representative Maximum inlet pressure 1 bar abs...

Страница 6: ...system The nitrogen system can be used in a number of different ways nitrogen is used as dilution gas It is injected inside the cylinder on two different places Nitrogen flow injected in the middle ho...

Страница 7: ...hen installing the pump in potentially explosive environments The maintenance instructions must be observed and respected It is vital that these installation and maintenance instructions are read and...

Страница 8: ...supply l Switch off the water and nitrogen quick connections inlet first then outlet l Put the label or warning board Maintenance processing on or next to the pump Emergency off circuit description l...

Страница 9: ...to add a belt or rope at a suitable point when lifting the pump l Attach lifting gear securely to the eyebolt or eyebolts l Use lifting gear with a crane hook equipped with safety latch l Lift the vac...

Страница 10: ...ure 2 5 bar relative Water hardness 5 dGH NOTE 1 german degree 1 dGH 1 78 french degree 1 25 e english degree 17 9 mg kg CaCO3 american hardness Minimum flow rate 3 4 l min for the standard version l...

Страница 11: ...least equal to the diameter of the exhaust flange of the vacuum pump to prevent a drop in the performance of the vacuum pump in the case of a smaller cross section l Make sure that the vacuum pump is...

Страница 12: ...ion it can be destroyed even if this is the case for only a short moment Make sure that the vacuum pump is connected correctly before switching it on l Determine rotation sense of the motor by using a...

Страница 13: ...from the intake flange and connect the intake line to the intake flange CAUTION In case of a vacuum pump filled with oil make sure that by lifting the inclination angle of the vacuum pump do not exce...

Страница 14: ...ants will result in damage to the vacuum pump CAUTION The cooling water flow which is checked by the flowmeter CWM must be at least 3 4 l min l Make sure that all caps safeguards and similar covers ar...

Страница 15: ...hat there are no cleaning tools in the pump anymore according to local and national regulations Before pulling off the different connections make sure that the intake and exhaust lines of the vacuum p...

Страница 16: ...l change intervals A drop in the oil level indicates a fault see Alarms and warnings Busch PLC and Busch LCD CAUTION Only fill in oil through the oil filler opening CAUTION Danger of burns when the oi...

Страница 17: ...nd that they do not leak CAUTION Only fill in oil through the oil filler opening l Unscrew the oil filler cap OFP l Fill in oil up to the middle of the oil sight glass l Make sure that the oil level l...

Страница 18: ...ful foreign material These foreign materials can infiltrate the pores recesses and other internal spaces of the vacuum pump Danger to health during dismantling of the vacuum pump Danger to the environ...

Страница 19: ...nditions which could cause personal injury Oil quantity The quantity of oil specified in the following table is of informative nature only Check the oil level with the help of the various oil sight gl...

Страница 20: ...overpressure bar 1 5 Oil quantity l 1 52 Weight kg 310 with silencer at exhaust Technical data BC 2000 F Effective suction capacity m3 h cfm 1580 930 Ultimate pressure Torr mbar 2 25 x 10 3 3 x 10 3...

Страница 21: ...in electrical and electronic equipment and following the standards Person authorised to compile the technical file Gerd Rohweder Busch Dienste GmbH Schauinslandstr 1 DE 79689 Maulburg Icheon si 01 06...

Страница 22: ...Note...

Страница 23: ...Note...

Страница 24: ...l Italy info busch it Japan info busch co jp Korea busch busch co kr Malaysia busch busch com my Mexico info busch com mx Netherlands info busch nl New Zealand sales busch co nz Norway post busch no P...

Отзывы: