Installation | 5
Instruction Manual COBRA NC 2500 B WCV_EN_en
11 / 44
5
Installation
5.1 Installation Conditions
NOTICE
Use of the machine outside of the permitted installation conditions.
Risk of premature failure!
Loss of efficiency!
• Take care that the installation conditions are fully complied with.
• Make sure that the environment of the machine is not potentially explosive.
• Make sure that the ambient conditions comply with the
.
• Make sure that the environmental conditions comply with the protection class of the
motor and the electrical instruments.
• Make sure that the installation space or location is vented such that sufficient cool-
ing of the machine is provided.
• Make sure that cooling air inlets and outlets of the motor fan are not covered or ob-
structed and that the cooling air flow is not affected adversely in any other way.
• Make sure that the oil sight glass (OSG) remains easily visible.
• Make sure that enough space remains for maintenance work.
• Make sure that the machine is placed or mounted horizontally, a maximum of 1° in
any direction is acceptable.
• Check the oil level, see
• Check the cooling liquid level, see
Cooling Liquid Level Inspection [
If the machine is installed at an altitude greater than 1000 meters above sea level:
• Contact your Busch representative, the motor should be derated or the ambient
temperature limited.
5.2 Connecting Lines / Pipes
WARNING
Rotating Parts.
Risk of severe injury!
• Do not operate the machine without suction / discharge connection installed.
• Remove all protective covers before installation.
• Make sure that the connection lines cause no stress on the machine‘s connection; if
necessary use flexible joints.
• Make sure that the line size of the connection lines over the entire length is at least
as large as the connections of the machine.
In case of long connection lines it is advisable to use larger line sizes in order to avoid
a loss of efficiency. Seek advice from your Busch representative.