CH Priority
–
Priority
pump
heating system
-
DHW Priority
–
Priority pump for
domestic hot water
-
Parallel Pumps
– parallel operation of
both pumps.
-
Summer Mode
– Summer mode. Burner
works for heating of domestic hot water
only.
Select the desired option using the
navigation arrows. Use the „
F
” button to
open the next page of the menu.
i
Important – The use of “External
room thermostat for the
burner” option (Thermostat) is
active only if option is selected
(CH Priority – priority of central
heating installation pump).
10.2.3. Automatic mode of operation
“Auto”
The burner goes
into
automatic
mode of operation
“
Auto
”.
In
this
operation mode the
ignition and the combustion process are
automatic as well as the pump control.
The burner operates in this mode until
the maximum preset temperature has
been reached. It then enters into
“
Suspend
” mode.
10.2.4. Burner shut-down “Standby”
Pressing the “
F
”
button will take you
to the main menu
and by using the
navigation arrows
you can select the “
Standby
” menu and
confirm the selection by pressing “
F
”. The
burner goes into extinguishing mode.
10.2.5. Setting up delayed start
From the start-up
screen, press „
F
” to
enter
into
the
burner
status
“
Switch Mode
”. Use
the navigation arrows to select the
“
Programme
” menu and confirm your
selection by pressing the “
F
” button.
This will open a menu where within a 24-
hour period you can set up to 3 /three/
delayed start-ups and shut-downs of the
burner.
Example:
The
picture shows the
first
checkmark
being set and next
to it is the start-up
time at 06:00 and burner shut-down time
at 22:00.
Programming desired time:
- Activate the checkmark in the box
Select the desired option using the
navigation arrows. Use the „
Enter
” button
to open the next page of the menu.
Heating priority selection - Menu.
From this menu you
can
select
the
priority of one of
the two pumps:
(
CH Priority
) or (
DHW Priority
).
Parallel Pumps
– parallel operation of
both pumps.
Summer Mode.
Important – The use of “External
thermostat for the burner” option
is active only if option is selected
(CH Priority – priority of central
heating installation pump).
Use the navigation arrows to select the
desired priority and press the “
F
” button