5
If you do not follow these instructions exactly, a fire or explosion may result
If you cannot reach your gas supplier, call the
B. Do not use this appliance if any part has been under
control system and any gas control which has been
to inspect the appliance and to replace any part of the
water. Immediately call a qualified service technician
FOR YOUR SAFETY READ BEFORE OPERATING
to be performed.
1. Set the thermostat or operating control to the lowest setting.
3. Turn off all electric power to the appliance if service is
TO TURN OFF GAS TO APPLIANCE
phone in your building.
Do not try to light any appliance.
Immediately call your gas supplier from a neighbor's
phone. Follow the gas supplier's instructions.
Do not touch any electric switch; do not use any
WHAT TO DO IF YOU SMELL GAS:
WARNING:
BEFORE OPERATING
4. This appliance is equipped with an ignition device
gas is heavier than air and will settle on the floor.
for gas. Be sure to smell next to the floor because some
C. smell all around the appliance area
which automatically lights the pilot. Do not try to light
A. This appliance is equipped with an ignition device
5. Make sure the manual main shut-off valve(s) and pilot
3. Turn off all electric power to the appliance.
1. STOP! Read the safety information above on this label.
2. Set the thermostat or operating control to lowest setting.
the pilot by hand.
OPERATING INSTRUCTIONS
under water.
causing property damage, personal injury, or loss of life.
fire department.
81460073R3
valve(s) have been shut off for at least five minutes.
shut-off for at least five minutes.
which automatically lights the pilot. Do not try to
light the pilot by hand.
6. Turn manual main shut-off valve(s) and pilot valve(s)
to "ON" position.
7. Turn on main electric switch.
Make sure that all limit controls have been set for
8. Set thermostat or operating control to desired setting.
normal system operating requirements.
Pilot will automatically ignite main burners on each call
for heat.
Then smell for gas, including near the floor.
If you smell gas, STOP! Follow "B" in the safety
information above on this label.
If you do not smell gas, go to the next step.
2. Close manual main shut-off valve(s) and pilot valve(s).
Figure 3: Operating Instructions, EI Intermittent Ignition System
USA Only: 5010B thru 5026B
Canada: All