Installation / Service / User Manual
BURNERTECH
11
3.5.1
Burner Wiring Diagrams
– Inverterjet M Series
X3 Microfit
*X2 Communication
(see note)
X1 Minifit
NOTE:
In the diagram shown, the
X1 Minifit
connector contains the High Voltage (230VAC) connections,
and the
X3 Microfit
connector contains the safety extra low voltage connections.
X2 Microfit
connector is used for communication via a dedicated Windows based PC software and
USB lead (Please contact Burnertech for more information).
An Earth must be connected to the 6.3mm spade connector on the gas valve, not to signal ground
on X3
HL must be normally closed for the control to operate, if a Hi Limit stat is not used, then a link must
be fitted between
X3.3
and
X3.10.
Heat demand is given by 230VAC input.
*For use with dedicated Windows based
USB
interface, please contact Burnertech for more
information about this option