4.
3 WARNINGS
1
Read the instructions before using this appliance.
2
This appliance requires installation by a competent qualified person.
3
Use only in a correctly sized and ventilated area.
4
Once the coals have been positioned in accordance with the installation instructions,
they must not be moved except for servicing.
5
The surfaces of the appliance become very hot during use.
6
Before cleaning or maintenance switch fire OFF and allow to cool.
7
Any purpose provided ventilation should be checked regularly to ensure it is free from
obstruction.
Overall Dimensions
4 Hearths, floor protection and carpets
This appliance does not need a hearth and can be used on wooden, laminate floors and non-
combustible surfaces. It must not be placed directly onto carpets or rugs. Where the floor is
carpeted, the carpet must finish 100mm clear of the appliance legs and be fully removed
underneath. Loose rugs should be kept well away from the appliance (warn the customer of this).
Standing the appliance directly on a floor can lead to discolouration and / or drying out.
When a hearth is used, the top surface can be wood but be aware that heat can discolour certain
finishes over a period of time and can dry out poorly seasoned wood causing splitting. The hearth
should be 100mm larger than the appliance all round and minimum 12mm thick. Carpets can come
to the edge of the hearth.
5 Clearance to Walls
Rear Clearance
- The rear of the appliance can be installed directly against a non combustible wall.
A distance of 50mm should be allowed to walls with wooden cladding, wallpaper, or finishes likely
to be affected by heat.
Side Clearance
- The sides of the appliance can be installed with 25mm of side clearance to non
combustible materials but this should be increased to 150mm for combustibles.
The fireplace and ALL materials including paints or lacquers must be rated for a minimum constant
temperature of 150°C. Any hearth or back panel not meeting the above clearance dimensions must
be made from a non-combustible material such as marble or slate, although ‘lightweight’ and tiled
surrounds can be used provided they have a minimum heat rating of 150°C.
540
620
250
Outlet grille
DO NOT COVER
Air inlets
DO NOT BLOCK