10
Technical data
6.5.2
Electrical data, IO-Link
Protection class
III as per DIN EN 61140
(VDE 0140-1)
Connection
Circular plug-in connector M12 x
1, 5-pin, A-coded
Port Class A
Operating voltage
24 V DC ±25%
(according to specifications)
Current consumption
max. 150 mA
Port Class B
Operating voltage
System supply (Pin 1+3)
24 V DC ±25 %
(according to specification)
Actuator supply (Pin 2+5)
2)
24 V DC ±25 %
(according to specification)
Current consumption
System supply (Pin 1+3)
max. 50 mA
Actuator supply (Pin 2+5) max. 120 mA
Total power consumption
max. 3.5 W
2) Actuator supply is galvanically isolated from the system supply in
accordance with IEC 60664 and for electrical safety in accordance with
SELV from IEC 61010-2-201
6.5.3
Electrical data, büS
Protection class
III as per DIN EN 61140
(VDE 0140-1)
Connection
Circular plug-in connector M12 x 1,
5-pin, A-coded
Operating voltage
24 V DC ±25 %
(according to specification)
Current consumption
max. 150 mA
Total power consumption max. 3.5 W
6.6
Pneumatic data
Control medium
Neutral gases, air
Quality classes in accordance with ISO
8573-1
Dust content
Class 7, max. particle size 40 µm, max.
particle density 10 mg/m³
Water content
Class 3, max. pressure dew point -20 °C
or min. 10 °C below the lowest operating
temperature
Oil content
Class X, max. 25 mg/m³
Temperature range 0 – +60 °C
Pressure range
1.4 – 7 bar
Type 8791 REV.2