background image

!

Depending  on  the  parameter's  setting,  the  actuator  will  move
erratically when an input current of 4mA DC is applied.

!

There  is  a  capacitor  for  noise  prevention  between  FG  terminal  (case)
and  each  input  /  output  terminal  of  the  positioner  respectively.
Therefore,  avoid  conducting  withstand  voltage  testing  or  insulation
resistance testing between the terminal and case.

!

Please refer to the Operation manual for further details. 

2

INTENDED CONDITIONS OF USE

2.1 Specifications

Protect  the  unit  from  impact  and  dropping  during  installation  and  when
mounted. This may cause failure of the unit. 

!

Do  not  use  the  unit  in  places  with  high  humidity  &  temperature. 
This may cause malfunctions.

!

Do not use this positioner outside of the range of it's specifications as
this can cause failure.

Table1 Specifications

*1: 1/2  split  range  is  available  using  the  split  range  setting  (parameter

code: 300).

*2: <Ex.>  When  applying  an  input  current  of  80mA  DC,  an  input  power

supply  voltage  of  12.5V  DC  or  less  will  prevent  damage  to  the
positioner.

Max. supply power = 80mA DC×12.5V = 1W

*3: If the feedback lever assembled to the positioner rotating angle is 30

°

or less, its stroke can be adjusted optionally in a range from 0 to 10

°

and from 0 to 30

°

. Please set the operation angle of the feedback

lever to 10

°

when accuracy is required.

*4: Linearity is a characteristic checked without loads using a factory

inspection machine. The positioner can not work independently and is
used as a part of loop including actuating equipment such as a valve,
actuator and DCS. Therefore, it should be noted that the described
characteristic values may vary depending on the loop conditions.

*5: (ANR) indicates standard air in accordance with JIS B0120.

Table2 Specifications of options

*6: When  no  input  current  has  been  applied,  an  alarm  is  output.  Fig.  1

shows an internal alarm circuit.

Read this manual before using this product

!

The  information  within  this  document  is  to  be  used  by  pneumatically
trained personnel only.

!

For future reference, please keep manual in a safe place.

!

This manual should be read in conjunction with the current catalogue.

1

SAFETY RECOMMENDATION

1.1 General recommendation

These safety instructions are intended to prevent a hazardous situation
and/or equipment damage. These instructions indicate the level of
potential hazard by label of "Caution", "Warning" or "Danger".

To ensure safety of personnel and equipment the safety instructions in this
manual and the product catalogue must be observed, along with other
relevant safety practices.

WARNING:

The  compatibility  of  pneumatic  equipment  is  the  responsibility  of  a  person
who designs the pneumatic system or decides its specification.

!

Since  the  products  specified  here  are  used  in  various  operating
conditions, their compatibility for the specific pneumatic system must
be based on specifications or after analysis and/or tests to meet your
specific requirements.

Only  trained  personnel  should  operate  pneumatically  operated  machinery
and equipment.

!

Compressed air can be dangerous if an operator is unfamiliar with it.
Assembly,  handling  or  repair  of  pneumatic  systems  should  be
performed by trained and experienced operators.

Do not service machinery/equipment or attempt to remove components until
safety is confirmed.

!

Inspection  and  maintenance  of  machinery/equipment  should  only  be
performed after confirmation of safe of dangerous fluid.

!

When  equipment  is  to  be  removed,  confirm  the  safety  process  as
mentioned above. Switch off air and electrical supplies and exhaust all
residual compressed air in the system.

!

Before machinery/ equipment is re-started, ensure all safety measures
to  prevent  sudden  movement  of  cylinders  etc.  (Bleed  air  into  the
system  gradually  to  create  backpressure,  i.e.  incorporate  a  soft-start
valve).

Contact SMC if the product is to be used in any of the following conditions:

!

Conditions  and  environments  beyond  the  given  specifications,  or  if
product is used outdoors.

!

Installation  on  equipment  in  conjunction  with  atomic  energy,  railway,
air  navigation,  vehicles,  medical  equipment,  food  and  beverages,
recreation  equipment,  emergency  stop  circuits,  press  applications,  or
safety equipment.

!

An application, which has the possibility of having negative effects on
people, property, or animals, requiring special safety analysis.

CAUTION:

!

Ensure that the air supply system is filtered to 0.3 micron.

1.2 Specific recommendations

!

If the input current is disconnected during use, the output of OUT1 will
become  0MPa  and  the  output  of  OUT2  will  reach  its  maximum,
regardless  of  the  operating  direction  of  the  parameter  mode
(parameter code: 200), whether direct or in reverse.

!

If  reverse  operation  is  selected  in  parameter  mode  (parameter  code:
200),  when  the  power  supply  is  turned  off,  OUT1  output  will  become
0MPa  and  the  positioner  will  start  moving  toward  input  current
20mADC direction.

CAUTION:

Operator error could result in injury or equipment damage.

WARNING:

Operator error could result in serious injury or loss of life.

DANGER:

In extreme conditions, there is a possible result of serious

injury or loss of life.

IP8001-TFL21GB

Installation and Maintenance Manual

Series IP8001 Smart Positioner (Lever type)

!

Model 

Item 

IP8001-0**-*-*-Q 

Input current 

4

20mADC 

1

2 wire system,  

Separate power source unnecessary

 

e

r

o

m

 

r

o

 

C

D

A

m

5

8

.

3

 

t

n

e

r

r

u

c

 

m

u

m

i

n

i

M
Voltage between 
terminals 

12VDC 

Input resistance equivalent to 600Ω, at 20mADC

Max supply power 

1W

2

100mADC, 28VDC

Supply air pressure 

0.14

0.7MPa 

Standard stroke 

10

o

30

o

3

Sensitivity 

±0.2%F.S. or less 

4

Linearity 

±1%F.S. or less

4

s

s

e

l

 

r

o

 

.

S

.

F

%

5

.

0

 

 

s

i

s

e

r

e

t

s

y

H

 

s

s

e

l

 

r

o

 

.

S

.

F

%

5

.

0

±

 

y

t

i

l

i

b

a

t

a

e

p

e

R

/

.

S

.

F

%

5

0

.

0

 

 

t

n

e

i

c

i

f

f

e

o

c

 

e

r

u

t

a

r

e

p

m

e

T

 o

C or less 

Max output flow rate  

80 l/min(ANR) or more (SUP=0.14MPa)

5

2 l/min(ANR) or less (SUP=0.14MPa) 

5

Air consumption  

4 l/min(ANR) or less (SUP=0.4MPa) 

5

Ambient and operating  
fluid temperature  

-20

o

C to 80

o

C

Classification of degree  
of Protection 

JIS F8007 IP65 (IEC 60529) 

Communication 
Protocol 

HART communication 

Air connection ports 

Rc1/4 female thread (or G1/4 or 1/4NPT)

Electrical connections 

G1/2 female thread (or 1/2NPT or M20x1.5)

Body/Cover : Die cast aluminium 

Coating : Epoxy resin baked

Material  

Shaft / Screw : Stainless 

 

g

k

6

.

2

 

x

o

r

p

p

A

 

 

t

h

g

i

e

W

Model 

Item 

IP8001-0*2-*-Q 

Alarm output1, 2 

6

 

m

e

t

s

y

s

 

e

r

i

w

 

2

 

d

o

h

t

e

m

 

g

n

i

r

i

W
Power supply voltage 

10

28VDC 

Load current 

10

40mADC 

7

Internal resistance 

350Ω±10

 

s

s

e

l

 

r

o

 

C

D

A

m

5

.

0

 

e

g

a

k

a

e

l

 

t

n

e

r

r

u

C

 

s

s

e

l

 

r

o

 

c

e

s

m

0

5

 

e

m

i

t

 

e

s

n

o

p

s

e

R
Analogue output 

8

 

m

e

t

s

y

s

 

e

r

i

w

 

2

 

d

o

h

t

e

m

 

g

n

i

r

i

W
Supply source voltage 

10

28V DC 

Output current 

4

20mADC 

Load resistance  

0

750Ω

 

s

s

e

l

 

r

o

 

.

S

.

F

%

5

.

0

±

 

 

y

c

a

r

u

c

c

A

9

1

SAFETY RECOMMENDATION (CONTINUED)

    

˜

˜

˜

708233C

CHRYSSAFIDIS S.A./ ATHENS: 3 AGRINIOU STR, TAVROS - (+30) 210 4836315-20 / THESSALONIKI: DA12A STR, OT32, BIPE SINDOU - (+30) 2310 754681-4 / www.chryssafidis.com / [email protected] 

Отзывы:

Похожие инструкции для Chryssafidis P8001 Series