28
LF TARGET RPM
TOO HIGH !!
TUBE TOO SMALL
CHECK DISP RATIO
RT TARGET RPM
TOO HIGH !!
TUBE TOO SMALL
CHECK DISP RATIO
LF TARGET RPM
TOO LOW !!
TUBE TOO LARGE
CHECK DISP RATIO
RT TARGET RPM
TOO LOW !!
TUBE TOO LARGE
CHECK DISP RATIO
1. The Tube Size selected for the Left
Hand Dispenser is too small for the
application.
2. The Ratio selected for the Left Hand
Dispenser is not correct for the
application.
1. The Tube Size selected for the Right
Hand Dispenser is too small for the
application.
2. The Ratio selected for the Right
Hand Dispenser is not correct for the
application.
1. The Tube Size selected for the Left
Hand Dispenser is too large for the
application.
2. The Ratio selected for the Left Hand
Dispenser is not correct for the
application.
1. The Tube Size selected for the Right
Hand Dispenser is too large for the
application.
2. The Ratio selected for the Right
Hand Dispenser is not correct for the
application.
Refer to “Selecting the Correct Pump
Tubing” section of the manual.
Refer to recommended Dispense Ratio
on the product label.
Refer to “Selecting the Correct Pump
Tubing” section of the manual.
Refer to recommended Dispense Ratio
on the product label.
Refer to “Selecting the Correct Pump
Tubing” section of the manual.
Refer to recommended Dispense Ratio
on the product label.
Refer to “Selecting the Correct Pump
Tubing” section of the manual.
Refer to recommended Dispense Ratio
on the product label.
Screen
Displayed
Possible
Cause Troubleshooting
Procedures
Dispenser Diagnostics-LCD Display
Troubleshooting (Continued)
36026 041204
LEFT PUMP FAULT!
CHK PUMP WIRING
CHK RPM SENSOR
CHK TUBING AREA
RT PUMP FAULT!
CHK PUMP WIRING
CHK RPM SENSOR
CHK TUBING AREA
1. Motor failure
2. RPM Sensor failure
1. Motor failure
2. RPM Sensor failure
Service Required
Service Required
Service Required
Service Required
Содержание LCR-2
Страница 36: ...36 36026 073107 ...